Technical content

Specifications are subject to change w ithout no tice C TD -1X D S EN G 14 0 116 1

  • C able and bus-bar type current transform er
  • 0.5 class, currents from 50 to 300 A
  • R em ovable D IN -rail m ounting holder
  • R em ovable panel fixing clips
  • 2 cable/bus-bar isolated fixing screw s
  • D ouble screw term inals (up to 8-w ire connections)
  • Sealable term inal block covers Product De scrip tion M odel Prim ary current Secondary current O ption O rdering Key C able/B us-bar type current transform er w ith D IN -rail/bus- bar and panel m ounting facility. Rated prim ary currents from 50 A to 3 0 0 A. Accessories AC Current Transform er (m ax 23m m Ø cable) Type CTD-1X Type Selection R ated secondary current 5 A or 1 A O utput Specifications Input Specifications O perating frequency 4 8 to 6 2 H z M ax. system voltage 0 .72 kV R ated insulation level 3 kV/1 m in. @ 50 H z Insulation class E (m ax 75°C ) Short-tim e current rating Ith Typical 10 0 I n /1 s Idyn 2.5 I th The short-tim e therm al current I th is anyw ay lim ited by the cable/bus-bar size Extended current rating 120 % Security factor (F S) ≤ 5 (C lass: 0 .5, 1 and 3 ) Standards According to EN 6 186 9-2 H ousing AB S, self-extinguishing: U L 94 V-0 M ounting D IN -rail bus-bar and panel m ounting Standard accessories Tw o term inal block screw s. Tw o sealable term inal block covers. Tw o panel m ounting fixing clips. O ne D IN rail adapter. O ptional accessories Extended fixing kit C TD -kit: Six cable/bus-bar fixing screw s. Six plastic caps for cable/bus-bar fixing screw s. G eneral Specifications CTD-1X 100 5A XXX Prim ary current F rom 50 to 3 0 0 A (R efer to R ange Table) O ption XXX: none XTX: tropicalization Secondary current Tw o panel m ounting fixing clips. Special features 1 A secondary current, Tropicalization W orking tem perature -25°C to +6 0 °C (-13 °F to 14 0 °F ) (R .H . < 90 % non condensing @ 4 0 °C ) Storage tem perature -3 0 °C to +70 °C (-22°F to condensing @ 4 0 °C ) Approvals C E, cU rus and C SA C onnection Screw type C able cross section area F rom 1.5 to 6 m m 2 M in/M ax screw s tightening torque relevant to term inal block screw s: F rom 1 to 2 N m M ax screw s tightening torque relevant to the cable/bus-bar fixing screw s: 0 ,3 N m Protection degree IP0 0 IP20 (w ith sealable term inal block covers + w ire term i nals) C able diam eter M ax. 23 m m B us-bar size M ax. 20 x5 m m W eight F rom 150 to 20 0 g O ptional fixing kit: CTD-kit

2 Specifications are subject to change w ithout no tice C TD -1X D S EN G 14 0 116

Dim ensions (m m ) Range Table C TD -1X Benefits 65,2 φ23,3 83,6 69,2 M odel C TD -1X from 50A to 100A Prim ary C urrent B urden (VA) A C L 0.5 C L 1 C L 3 50 (@ 6 0 °C /14 0 °F ) 1 1.25 6 0 (@ 6 0 °C /14 0 °F ) 1 1.25 70 (@ 6 0 °C /14 0 °F ) 1.5 1.75 75 (@ 6 0 °C /14 0 °F ) 1 1.25 1.75 80 (@ 6 0 °C /14 0 °F ) 1.25 1.5 2 10 0 (@ 6 0 °C /14 0 °F ) 1.5 1.75 2.25 M odel C TD -1X from 120A to 300A Prim ary C urrent B urden (VA) A C L 0.5 C L 1 C L 3 120 (@ 6 0 °C /14 0 °F ) 1.75 2 2.5 125 (@ 6 0 °C /14 0 °F ) 2 2.25 2.75 150 (@ 6 0 °C /14 0 °F ) 2.25 2.5 3 16 0 (@ 6 0 °C /14 0 °F ) 2.5 2.75 3 .25 20 0 (@ 6 0 °C /14 0 °F ) 3 3 .25 3 .75 250 (@ 50 °C /122°F ) 4 .5 4 .75 5.25 3 0 0 (@ 50 °C /122°F ) 5 5.5 6 1 2 3 4 5 6 7 8 9 W iring Diagram

  • Easy and quick m ounting either on a panel or on a D IN -rail (see figure 1-2).
  • Protection of screw term inals using specific sealable covers to assure alw ays the best safety (see figure 3 ).
  • B ridging of current transform er output w ithout changing the connection of the secondary, so to avoid any output overvoltage during either the m aintenance or the installation procedure (see figure 4 ).
  • Easy output and earth connection (see fig. 5).
  • Screw term inals com patible w ith any kind of w ire term inals (see figure 6 -7-8-9).
  • M ultiple screw s provided w ith insulation caps to grant a strong and reliable fixing of the current transform er to the bus-bar (see figure 10 ). S1 S2 L N P1 P2