Input Voltage • 85-264 VAC (120-370 VDC) Input Frequency • 47-63 Hz Inrush Current • 15/30 A at 120/230 VAC in, 100% load & 25 °C Power Factor • 0.99 typical at 100 VAC, 0.93 typical at

200 VAC & 100% load to IEC61000-3-2

Earth Leakage • 0.75 mA max at 230 VAC 60 Hz Current Output Output Voltage • See Tables Output Voltage • ±10% V1 only Adjustment Minimum Load • No minimum load required Start Up Time • V1 250 ms, V2 500ms Hold Up Time • V1 40 ms, V2 20 ms at 120 VAC Line Regulation • 0.4% max over specified input range Load Regulation • 0.8% max for a 100% load change Ripple & Noise • 150 mV pk-pk max (0 °C to +50 °C) Overcurrent • >105% of rated current on V1 & >101% Protection of peak current on V2 auto recovery Overvoltage • >115% of nominal value for V1 & Protection 115-140% of nominal value for V2 General Efficiency • 74-83% depending on specific model Isolation • 3000 VAC Input to Output

2000 VAC Input to Ground

500 VAC Output to Ground

V1 to V2 100 VAC 1 min, cut off current 100 mA,

100 VDC 10 MΩ min

Switching Frequency • 80-500 kHz Options • Designated by the following suffixes to the model number: Reduce leakage current <0.1 mA ‘-G’ Remote ON/OFF ‘-R’ Cover fitted ‘-C’ Screw terminals ‘-T’ Add 4 outputs by the addition of a DC-DC converter to the board ‘-Z’ Contact Sales Office Environmental Operating • -10 °C to +70 °C (See Derating Curve) Temperature Storage • -20 °C to +75 °C Temperature Humidity • 20-90% RH, non condensing Shock • 196.1 m/s 2 (20 G), 11 ms once each X, Y & Z axis Vibration • 2 G 10-55 Hz, 3 axis EMC & Safety Emissions • EN55022 Level B conducted EN55022 Level B radiated ESD Susceptibility • EN61000-4-2 Level 2 contact Level 3 air Radiated • EN61000-4-3 Level 3 Susceptibility EFT/Burst • EN61000-4-4 Level 3 Surge • EN61000-4-5 Level 3 line to line Level 4 line to ground Safety Approvals • UL1950, C-UL, EN60950, VDE0160 100-225 Watts CPL Series AC-DC Open Frame Specification THE XP ERTS IN POWER www.xpplc.com sales@xpplc.com

  • Isolated Outputs High Peak Current Ratings Compact PCB Construction Optional Remote On/Off Adjustable Output Voltage EN55022 Level B Cover, Connector & Loom Kits Available

I/O Connector Mating Connector Terminal CN1 B3P5-VH VHR-5N Chain: SVH-21T-P1.1 Loose: 8VH-21T-P1.1 CN2 B8P-VH VHR-8N Chain: SVH-21T-P1.1 Loose: 8VH-21T-P1.1 CN3 B2B-XH-A XHP-2 Chain: SXH-001-P0.6 (Option) Loose: BXH-001T-P0.6 CN4 B3B-XH-A XHP-3 Chain: SXH-001-P0.6 (Option) Loose: BXH-001T-P0.6 OUTPUT VOLTAGE & CURRENT RATINGS - 100 WATT MODEL CPL 1. Peak rating for 10 sec with a duty cycle of 35% max. 2. Measured with 22µF cap within 150 mm of output terminal at 20 MHz bandwidth. 3. Measured at 200 VAC input & 100% load. Notes Mechanical Details - 100 Watt Models Derating Curves - 100 Watt Models www.xpplc.com sales@xpplc.com Output Current Rating Regulation Ripple & Efficiency (3) Model Voltage Maximum Peak (1) Line Load Noise pk-pk (2) Typical Number +5 V1 5.0 A - 20 mV 40 mV 120 mV 80% CPL100PD24+24 V2 4.0 A 7 A 96 mV 150 mV 150 mV +5 V1 5.0 A - 20 mV 40 mV 120 mV 76% CPL100PD12+12 V2 5.0 A 10 A 48 mV 100 mV 150 mV CN1 Pin No. Input

1 AC(L)

3 AC(N)

Pin No. Output 1, 2 G2 3, 4 V2 5, 6 G1 7, 8 V1 CN3 (Optional) Pin No. Remote On/Off

1 RC(+)

2 RC(-)

CN4 (Optional) Pin No. ‘-Z’

2 COM

OPEN FRAME COVER FITTED (>90 VAC INPUT) NOTES:

  • Weight 420g or less (without chassis & cover).
  • Tolerance ±1.
  • Dimensions in mm.
  • PCB Material : CEM3.
  • Optional chassis & cover, order part no. CPL100 COVER or add suffix ‘-C’ to the model number to receive the unit with the cover fitted.
  • Mounting torque 1.5N m (16 kgf cm) max.
  • Keep drawing current per pin below 5 A (7 A @ pk load) for CN2.
  • Optional connector kit available, order part no. CPL100/150 CON.
  • Optional loom kit available, order part no. CPL100/150 LOOM.

www.xpplc.com sales@xpplc.com I/O Connector Mating Connector Terminal CN1 B3P5-VH VHR-5N Chain: SVH-21T-P1.1 Loose: 8VH-21T-P1.1 CN2 B8P-VH VHR-8N Chain: SVH-21T-P1.1 Loose: 8VH-21T-P1.1 CN3 B2B-XH-A XHP-2 Chain: SXH-001-P0.6 (Option) Loose: BXH-001T-P0.6 CN4 B3B-XH-A XHP-3 Chain: SXH-001-P0.6 (Option) Loose: BXH-001T-P0.6 CN1 Pin No. Input Pin No. Output 1, 2 G2 3, 4 V2 5, 6 G1 7, 8 V1 CN3 (Optional) Pin No. Remote On/Off CN4 (Optional) Pin No. ‘-Z’ NOTES:

  • Weight 530g or less (without chassis & cover).
  • Tolerance ±1.
  • Dimensions in mm.
  • PCB Material : CEM3.
  • Optional chassis & cover, order part no. CPL150 COVER or add suffix ‘-C’ to the model number to receive the unit with the cover fitted.
  • Mounting torque 1.5N m (16 kgf cm) max.
  • Ensure current per pin is below 5 A (7 A @ pk load) for CN2.
  • Optional connector kit available, order part no. CPL100/150 CON.
  • Optional loom kit available, order part no. CPL100/150 LOOM. OPEN FRAME COVER FITTED (>90 VAC INPUT) 1. Peak rating for 10 sec with a duty cycle of 35% max. 2. Measured with 22 µF cap within 150 mm of output terminal at 20 MHz bandwidth. 3. Measured at 200 V AC input & 100% load. OUTPUT VOLTAGE & CURRENT RATINGS - 150 WATT MODEL CPL Output Current Rating Regulation Ripple & Efficiency (3) Model Voltage Maximum Peak (1) Line Load Noise pk-pk (2) Typical Number +5 V 1 5.0 A - 20 mV 40 mV 120 mV 82% CPL150PD24+24 V 2 6.0 A 10 A 96 mV 150 mV 150 mV +5 V 1 5.0 A - 20 mV 40 mV 120 mV 79% CPL150PD12+12 V 2 7.5 A 14 A 48 mV 100 mV 150 mV Notes Mechanical Details - 150 Watt Models Derating Curves - 150 Watt Models

www.xpplc.com sales@xpplc.com I/O Connector Mating Connector Terminal CN1 B3P5-VH VHR-5N Chain: SVH-21T-P1.1 Loose: 8VH-21T-P1.1 CN2 B8P-VH VHR-8N Chain: SVH-21T-P1.1 Loose: 8VH-21T-P1.1 CN3 B2B-XH-A XHP-2 Chain: SXH-001-P0.6 (Option) Loose: BXH-001T-P0.6 CN4 B3B-XH-A XHP-3 Chain: SXH-001-P0.6 (Option) Loose: BXH-001T-P0.6 CN1 Pin No. Input Pin No. Output 1, 2, 3 G2 4, 5, 6 V2 7, 8 G1 9, 10 V1 CN3 (Optional) Pin No. Remote On/Off CN4 (Optional) Pin No. ‘-Z’ NOTES:

  • Weight 700g or less (without chassis & cover).
  • Tolerance ±1.
  • Dimensions in mm.
  • PCB Material : CEM3.
  • Optional chassis & cover, order part no. CPL225 COVER or add suffix ‘-C’ to the model number to receive the unit with the cove r fitted.
  • Mounting torque 1.5N m (16 kgf cm) max.
  • Keep drawing current per pin below 5 A (7 A @ pk load) for CN2.
  • Optional connector kit available, order part no. CPL225 CON.
  • Optional loom kit available, order part no. CPL225 LOOM. OPEN FRAME COVER FITTED (>90 VAC INPUT) OUTPUT VOLTAGE & CURRENT RATINGS - 225 WATT MODEL CPL Output Current Rating Regulation Ripple & Efficiency (3) Model Voltage Maximum Peak (1) Line Load Noise pk-pk (2) Typical Number +5 V1 5.0 A - 20 mV 40 mV 120 mV 83% CPL225PD24+24 V2 9.0 A 14 A 96 mV 150 mV 150 mV +5 V1 5.0 A - 20 mV 40 mV 120 mV 79% CPL225PD12+12 V2 10.0 A 20 A 48 mV 100 mV 150 mV 1. Peak rating for 10 sec with a duty cycle of 35% max. 2. Measured with 22 µF cap within 150 mm of output terminal at 20 MHz bandwidth. 3. Measured at 200 V AC input & 100% load. Notes Mechanical Details - 225 Watt Models Derating Curves - 225 Watt Models Rev 3.0