Features
Description
Ordering Information
Security Passive Infrared Detectors (PIR) Data Signalling Sensor Circuitry Instrumentation Multiplexers Data Acquisition Electronic Switching I/O Subsystems Energy Meters Medical Equipment—Patient/Equipment Isolation Aerospace Industrial Controls 100% Solid State Voltage-controlled operation Matches popular reed relay pin-out Designed for use in security systems complying with EN50130-4 Small 4-Pin SIP Package Arc-Free With No Snubbing Circuits 2500V rms Input/Output Isolation No EMI/RFI Generation Immune to radiated EM fields Auto Pick & Place, Wave Solderable The CPC1217 is a voltage-controlled, single-pole, normally open (1-Form-A), optically coupled solid state relay configuration in a 4-pin Single In-line Package (SIP). Clare's patented OptoMOS architecture makes available the optically coupled technology necessary to activate the output's efficient MOSFET switches while providing a 2500V rms input-to-output isolation barrier. Control of the isolated output is accomplished by means of a highly effective GaAlAs infrared LED at the input while the internal resistor in series with the LED enables the input voltage-controlled operation. Because the input is solid state there is no need for snubbers or "catch" diodes to suppress the inductive flyback transient voltage normally associated with EMR coils. CPC1217 Pinout Switching Characteristics of Normally Open (Form A) Devices Approvals UL Recognized Component: File # E76270 EN/IEC 60950 Compliant CSA Certified Component: Certificate # 1172007 CONTROL ILOAD 10% 90% TON TOFF 1234
www.clare.com2 CPC1217 R03 Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at conditions beyond those indicated in the operational sections of this data sheet is not implied. Absolute Maximum Ratings Parameter Ratings Units Blocking Voltage 60 V P Reverse Input Voltage 5 V Input Control Voltage 15 V Input Power Dissipation 225 mW T otal Power Dissipation 1 800 mW Isolation Voltage Input to Output 2500 V rms Operational T emperature -40 to +85 °C Storage T emperature -40 to +125 °C 1 Derate Linearly 6.67 mw / ºC Electrical absolute maximum ratings are at 25°C Parameter Conditions Symbol Min Typ Max Units Output Characteristics @ 25°C Load Current Continuous VIN=5V I L - - 200 mA Peak t ≤10ms I LPK - - 400 On-Resistance 1 IL=200mA R ON -- 1 6 Ω Off-State Leakage Current V L=60VP ILEAK --1 μA Switching Speeds T urn-On (Output Closed) V IN=5V , VL=10V TON --5 ms T urn-Off (Output Open) T OFF --5 Output Capacitance V IN=0V , VL=50V; f=1MHz C OUT -2 5 - p F Input Characteristics @ 25°C Input Control Voltage Output Closed IL=200mA V IN - - 3.75 V Recommended Operating Range 5 - 12 Output Open 1- - Reverse Input Current V IN=-5V I R -- 1 0 μA Input Resistor - - 900 1000 1100 Ω Common Characteristics @ 25°C Capacitance, Input to Output - - - 1 - pF 1 Measurement taken within 1 second of on time.
Electrical Characteristics
www.clare.com 3R03 PERFORMANCE DATA* *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifi cations, please contact our application department. Device Count (N) On-Resistance (Ω) CPC1217 Typical On-Resistance Distribution (TA=25ºC, IL=100mA, VIN=5V) 84 86 88 9085 87 89 Blocking Voltage (V Device Count (N) CPC1217 Typical Blocking Voltage Distribution (TA=25ºC) Input Voltage (V) Device Count (N) CPC1217 Typical Input Voltage for Switch Operation (TA=25ºC, IL=100mA) Input Voltage (V) Device Count (N) CPC1217 Typical VOFF for Switch Dropout (TA=25ºC, IL=100mA) Turn-On (ms) Device Count (N) CPC1217 Typical Turn-On Time (TA=25ºC, IL=100mA, VIN=5V) Turn-Off (ms) Device Count (N) CPC1217 Typical Turn-Off Time (TA=25ºC, IL=100mA, VIN=5V) Load Current (mA) 225 200 175 150 125 100 CPC1217 Typical Maximum Load Current vs. Temperature Temperature (ºC) -40 -20 0 20 40 60 80 120 100 VIN = 5V Leakage (μA) -40 0.016 0.014 0.012 0.010 0.008 0.006 0.004 0.002 -20 0 20 40 60 80 100 CPC1217 Typical Leakage vs. Temperature Measured Across Pins 1 & 4) (VL=Max Rated) Temperature (ºC) Blocking Voltage (VP) -40 -20 0 20 40 60 80 100 Temperature (ºC) CPC1217 Typical Blocking Voltage vs. Temperature VIN = 5V Turn-On (ms) -40 0.30 0.27 0.24 0.21 0.18 0.15 0.12 0.09 0.06 0.03 -20 0 20 40 60 80 100 Temperature (ºC) CPC1217 Typical Turn-On vs. Temperature (IL=100mA) Turn-Off (ms) -40 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 -20 0 20 40 60 80 100 VIN = 5V Temperature (ºC) CPC1217 Typical Turn-Off vs. Temperature (IL=100mA) Input Voltage (V) Turn-On (ms) 0 51 0 1 5 2 0 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 CPC1217 Typical Turn-On vs. Input Voltage (IL=100mA)
www.clare.com4 CPC1217 R03 PERFORMANCE DATA* *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifi cations, please contact our application department. Input Voltage (V) Turn-Off (ms) 0 2 4 6 8 10 12 14 16 18 0.51 0.50 0.49 0.48 0.47 0.46 0.45 0.44 CPC1217 Typical Turn-Off vs. Input Voltage (IL=100mA) -40 -20 0 20 40 60 80 100 Steady State VIN = 5V Temperature (ºC) On-Resistance (Ω) CPC1217 Typical On-Resistance vs. Temperature (IL=Max Rated @ Temperature) Input Voltage (V) -40 -20 0 20 40 60 80 100 1.45 1.40 1.35 1.30 1.25 1.20 1.15 CPC1217 Typical Input Voltage for Switch Operation vs. Temperature (IL=100mA) Temperature (ºC) Input Voltage (V) -40 1.45 1.40 1.35 1.30 1.25 1.20 1.15 -20 0 20 40 60 80 100 CPC1217 Typical Input Voltage for Switch Dropout vs. Temperature (IL=100mA) Temperature (ºC) Load Voltage (V) Load Current (mA) 200 100 -200 150 -100 -50 -150 -1.00 0.50 CPC1217 Typical Load Current vs. Load Voltage (TA=25ºC, VIN=5V) Time Load Current (A) 10μs 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 1ms100μs 100ms 1s10ms 10s 100s CPC1217 Energy Rating Curve
Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare’s Standard Terms and Conditions of Sale, Clare, Inc. assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice. Specification: DS-CPC1217-R03 ©Copyright 2008, Clare, Inc. OptoMOS® is a registered trademark of Clare, Inc. All rights reserved. Printed in USA. 7/16/08 For additional information please visit our website at: www.clare.com MECHANICAL DIMENSIONS Dimensions: mm (inches) RoHS 2002/95/EC e3Pb 4-Pin SIP 19.202 ± 0.381 (0.756 ± 0.015) 6.401 ± 0.127 (0.252 ± 0.005) 5.944 ± 0.127 TYP 2.642 ± 0.127 TYP 0.254 ± 0.013 (0.010 ± 0.0005) 0.457 ± 0.076 TYP 5.080 ± 0127 (0.200 ± 0.005) 5.080 ± 0127 (0.200 ± 0.005) 3.302 ± 0.051 (0.130 ± 0.002) 3.251 ± 0.102 (0.128 ± 0.004) NOTES: 1. Leadframe thickness does not include plating. (1000 microinches maximum) 2. Pin location tolerances are non -accumulative. PIN 1 MANUFACTURING INFORMATION Soldering For proper assembly, the component must be processed in accordance with the current revision of IPC/JEDEC standard J-STD-020. Failure to follow the recommended guidelines may cause permanent damage to the device resulting in impaired performance and/or a reduced lifetime expectancy. Washing Clare does not recommend ultrasonic cleaning or the use of chlorinated solvents.