www.clare.com

Applications

Ordering Information

Clare’s Molded Ultra-Mini DYADTM is well suited for small, signal switching applications. The small size lends itself to surface mountable applications; working well on higher density PC boards. The Molded Ultra-Mini DYAD TM has sputtered ruthenium contacts and an extraordinary seal strength achieved by a patented laser sealing of the leads. In low level or dry switching environments, switches typically exceed 1 billion operations. In addition, the molding process provides a solid plastic outer shell. This plastic shell provides superior mechanical strength, eliminates concerns over handling glass switches, and provides an ideal solution for high speed, automated assembly environments. Standard Test Coil CM5 Part # Coil-1 Coil Definition NARM1 CTC01 Coil Resistance 1200Ω Number of Turns 5,000 Wire Size 0.0399mm (AWG 46) Bobbin Diameter (inside cell) 3.96mm Winding Length 10.4mm A complete part number is represented by the digits to the right. For example, CM5S1030 is a MOLDED ULTRA- MINI DYAD™ with a minimum operate value of 10NI and a maximum of 30NI. Refer to the switch operating specification charts for available ranges. Special ranges are available upon request. Surface Mount Molded Ultra-Mini DYAD Refer to operating characteristics table for complete part number. Molded Ultra-Mini DYAD™ Molded Ultra-Mini DYAD™ Surface Mount 1 Tolerance = ± 1.5NI

2 Full Blade Sensitivity

3 Surface Mount Switches are packaged 3,000 parts per reel

Part # Operate Range (NI) 1 CM5S1015 10 to 15 CM5S1020 10 to 20 CM5S1030 10 to 30 CM5S1520 15 to 20 CM5S1525 15 to 25 CM5S2025 20 to 25 Part # Operate Range (NI) 1,2,3 CM5-2319 10 to 15 CM5-2315 10 to 20 CM5-2376 10 to 30 CM5-2325 15 to 20 CM5-2341 15 to 25 CM5-2378 20 to 25 Molded Ultra-Mini DYAD™ CM5 DS-CM5-R1

  • Small size
  • SMT-compatible
  • Easily formed leads
  • Sputtered ruthenium contacts
  • Hermetically sealed contacts
  • Fast switching speed — up to 500Hz
  • Wide range of available magnetic sensitivities
  • Superior mechanical strength
  • Enhanced for better auto placement
  • Security − Proximity sensing − Smoke alarms
  • Automotive − Level sensor − Lamp current sensor
  • Relays The magnetic force (expressed in NI, AT or Ampere Turns) required to cause the reed switch contacts to close is called the pull-in or operate value. (1) Consult factory for test procedure. The reed switch shall be placed in the test coil with the gap centered in the core of the coil winding. Test leads and their clips must be non-magnetic. The longitudinal axis of the test coil and the test switch shall be vertical. /K43 /K4D /K35/K53/K58 /K58 /K58 /K58 /K4D/K61/K78/K69/K6D/K75/K6D /K6F/K70/K65/K72/K61/K74/K65 /K76/K61/K6C/K75/K65 /K4D/K69/K6E/K69/K6D/K75/K6D /K6F/K70/K65/K72/K61/K74/K65 /K76/K61/K6C/K75/K65 /K22/K53/K22 /K66/K6F/K72 /K73/K74/K72/K61/K69/K67/K68/K74 /K73/K77/K69/K74/K63/K68

www.clare.com CM5 Rev. 1 Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this data sheet is not implied. Exposure of the device to the absolute maximum ratings for extended period may degrade the device and effect its reliability. Absolute Maximum Ratings (@ 25˚ C) Molded Ultra-Mini DYAD™ Parameter Min Typ Max Units Switching Voltage CM5 - Molded Ultra Mini-DYAD™ - - 175 Volts Switching Current CM5 - Molded Ultra Mini-DYAD ™ - - 0.25 Amps Carry Current CM5 - Molded Ultra Mini-DYAD™ - - 0.50 Amps Switching Frequency CM5 - Molded Ultra Mini-DYAD ™ - - 500 Hz Contact Resistance CM5 - Molded Ultra Mini-DYAD™ - - 300 m Ω (See detailed specifications for more information.) Specifications All parameters are at 25°C unless otherwise stated. PARAMETER CONDITIONS SYMBOL MIN TYP MAX UNITS Contact Ratings Operate ampere turns range Full Blade Tolerance = ± 1.5NI AT 10 - 30 NI Release ampere turns range Full Blade Tolerance = ± 1.5NI AT 5 - 30 NI 5Switching Voltage Max DC/PeakAC Resistive V L - - 175 VDC Switching Current Max DC/PeakAC Resistive I L - - 250 mAmps Carry Current Max DC/PeakAC Resistive I C - - 0.5 Amps Contact Rating Max DC/PeakAC Resistive - - - 5 VA Life Expectancy 1V, 10mA Signal Level - - 1000 - x10

6 Ops

10V, 10mA Low Level - - 500 - -x10 6 Ops 50V, 100mA Telecom Load - - 2 - x10 6 Ops 100V, 100mA Rated Loads - - 2 - x10 6 Ops Static Contact Resistance 50mV, 10mA (1) CR - 120 300 Ω Contact Material - - Ru - - Switch Specifications Insulation Resistance (2) 100V, 25°C, 40% RH IR 10 9 1011 - Ω Capacitance Across Open Contacts - - 0.3 - pF Dielectric Strength(5) Between Contacts - 200 - - VDC/Peak AC Operate Time, At nominal coil voltage, T OP - - 0.4 ms including bounce 10Hz Square Wave Release Time Zener-Diode Suppression (3) TREL - - 0.1 ms Environmental Ratings Storage Temperature T A -40 - +125 ˚C Operating Temperature T O -40 - +125 ˚C Soldering Temperature - - - +265 ˚C Vibration 5Hz - 200Hz G - - 20 -Gs Shock 11 ±1ms, 1/2 Sine Wave S - - 30 Gs Shock - survivability 11 ±1ms, 1/2 Sine Wave S - - 500 Gs (1) Contact resistance measured with 4 terminal method, 1.1" between test leads (2) >1012 Ω is available upon request (3) A 24V zener in series with a diode across the coil (4) Use caution not to exceed vibration resistance limits while ultrasonically cleaning. Contact Clare, Inc. Engineering for more details/ recommendations (5) 15 ampere turn minimum

www.clare.comRev. 1 Mechanical Dimensions Dimensions mm inches Molded Ultra-Mini DYAD™

78 Cherry Hill Drive

Beverly, MA 01915 Tel: 1-978-524-6700 Fax: 1-978-524-4900 Toll Free: 1-800-27-CLARE Clare Switch Division

4315 Earth City Expresssway

St. Louis, MO 63045 Tel: 1-314-770-1832 Fax: 1-314-770-1812 Clare Micronix Division

145 Columbia

Aliso Viejo, CA 92656-1490 Tel: 1-949-831-4622 Fax: 1-949-831-4628 SALES OFFICES AMERICAS Americas Headquarters Clare Beverly, MA 01915 Tel: 1-978-524-6700 Fax: 1-978-524-4900 Toll Free: 1-800-27-CLARE Eastern Region Clare P.O. Box 856 Mahwah, NJ 07430 Tel: 1-201-236-0101 Fax: 1-201-236-8685 Toll Free: 1-800-27-CLARE Central Region Clare Canada Ltd.

3425 Harvester Road, Suite 202

Burlington, Ontario L7N 3N1 Tel: 1-905-333-9066 Fax: 1-905-333-1824 Western Region Clare

1852 West 11th Street, #348

Tracy, CA 95376 Tel: 1-209-832-4367 Fax: 1-209-832-4732 Toll Free: 1-800-27-CLARE Canada Clare Canada Ltd. Burlington, Ontario L7N 3N1 Tel: 1-905-333-9066 Fax: 1-905-333-1824 EUROPE European Headquarters CP Clare nv Bampslaan 17 B-3500 Hasselt (Belgium) Tel: 32-11-300868 Fax: 32-11-300890 France Clare France Sales Lead Rep 99 route de Versailles

91160 Champlan

Tel: 33 1 69 79 93 50 Fax: 33 1 69 79 93 59 Germany Clare Germany Sales ActiveComp Electronic GmbH Mitterstrasse 12

85077 Manching

Tel: 49 8459 3214 10 Fax: 49 8459 3214 29 Italy Via C. Colombo 10/A I-20066 Melzo (Milano) Tel: 39-02-95737160 Fax: 39-02-95738829 Sweden Clare Sales Comptronic AB Box 167 S-16329 Spå nga Tel: 46-862-10370 Fax: 46-862-10371 United Kingdom Clare UK Sales Marco Polo House Cook Way Bindon Road Taunton UK-Somerset TA2 6BG Tel: 44-1-823 352541 Fax: 44-1-823 352797 ASIA PACIFIC Asian Headquarters Clare Room N1016, Chia-Hsin, Bldg II, 10F, No. 96, Sec. 2 Chung Shan North Road Taipei, Taiwan R.O.C. Tel: 886-2-2523-6368 Fax: 886-2-2523-6369 http://www.clare.com Worldwide Sales Offices Specification: PB-CM5-R1 ©Copyright 2001, Clare, Inc. Molded Ultra-Mini DYAD™ , Molded Mini DYAD™ , and Molded DYAD ® are trademarks of Clare, Inc. All rights reserved. Printed in USA. 5/01/01 Clare cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in this Clare product. No circuit patent licenses nor indemnity are expressed or implied. Clare re- serves the right to change the specification and circuitry, without notice at any time. The products described in this document are not intended for use in medical implantation or other direct life support applications where malfunction may result in direct physical harm, injury or death to a person.