Specifications are subject to change without notice. These products are not intended for use as critical components in life support or nuclear systems. 40W / ULTRA-WIDE INPUT 16.8V-137.5VDC GENERAL FEATURES
- Fully EN50155 compliant, no external circuits
- Ultra-wide input range 11:1 reduces product variety
- Excellent efficiency, lowest power loss, full lifetime
- Full power up to +85° without heat sink, no derating
- Active input reverse polarity protection
- Active inrush current limitation - network pro- tection
- 10ms hold-up time over the entire input range
- Reinforced insulation, 6mm air/creepage dis- tances
- Trim-output for long cable runs or battery charging
- Parallel and redundant operation
- 50% Peak load capability to 60W for 10s
- Remote (on/off) and DC OK with open collector
- 2 years warranty
DESCRIPTION
The chassis mountable CLS-40 series DC/DC converter is designed for railway and transportation applications and is compliant with all relevant standards: EN50155, EN50121-3-2, DB-EMV06, EN50124-1, EN50125-1, EN61373 1B, EN62368-1, EN45545-2. The unit is designed with 11:1 input voltage range to cover the input voltages from 14.4VDC up to 154VDC for nominal 24, 36, 48, 72 and 110V in one range for all applications - on every vehicle worldwide. The isolated and regulated 24V output works with a reinforced isolation system. Due to the base plate mounting the unit operates with full power within the wide temperature for OT4+ST1&ST2 class from -40°C to +85°C and no additional cooling systems are necessary. Input reverse polarity protection, inrush current limitation, 10ms hold-up time, remote control, and output OR-ing diode and efficiency of up to 92% round up the functionality of this fully railway compliant Plug&Play unit. SELECTION GUIDE CLS-40 Dimensions (LxWxH): 100.0 x 60.0 x 30.0mm (3.94 x 2.36 x 1.18 inch) 145g (0.32 lbs) Part Number Input Voltage Range [VDC] Output Voltage nom. [VDC] Output Current max. (1) [A] Efficiency typ. [%] Output Power max. (1) [W] APPLICATIONSSAFETY & EMC Note1: Refer to “Peak load Capability” CLS-40-24 16.8-137.5 24 2.5 92 60
www.premiumpsu.com Powering Your Challenge 01-09-2025 CA-470-1 CLS-40 Parameter Conditions Min. Typ. Max. Input Voltage Range refer to “Input Voltage Range” nom. VIN= 24, 36, 48, 72, 110VDC 16.8VDC 137.5VDC according to EN 50155 100ms max 14.4VDC 16.8VDC 1s max. 137.5VDC 154VDC Input Capacitance internal 3µF Under Voltage Lockout rising edge 15VDC 16VDC falling edge 14.4VDC hysteresis 1VDC Input Current VIN=16.8VDC 3A 4A VIN= 24VDC 2A 3A VIN= 110VDC 0.44A 0.67A Inrush Current active inrush current limitation (<3.5 x Inom) 14A No Load Power Consumption 2W Standby Power (shutdown by remote) 0.5W Output Current Range continuous operation 0A 1.667A 10s max., refer to “Peak load Capability” 2.5A Output Voltage 24VDC Output Voltage Trimming 21.6VDC 26.4VDC Minimum Load 0% Start-up time VIN= 24VDC 0.5s VIN= 110VDC 0.2s by using CTRL ON/OFF function 0.2s Rise time 100ms Hold-up time VIN= 24VDC 25ms VIN= 48VDC 15ms ON/OFF CTRL DC-DC ON open or connected to +VIN DC-DC OFF connected to -VIN Input Current of CTRL pin DC-DC ON 10mA Internal Operating Frequency 80kHz Output Ripple and Noise 10µF electrolytic capacitor in parallel across the output (low ESR) 240mVp-p Maximum Capacitive Load VIN= 16.8-24VDC 1500µF VIN= 24-137.5VDC 2500µF BASIC CHARACTERISTICS MODEL NUMBERING CLS-40-6515 Nominal Power Model number (measured @ T = 25°C, nom. V , full load and after warm-up unless otherwise stated) AMB IN
www.premiumpsu.com Powering Your Challenge 01-09-2025 CA-470-1 CLS-40 BASIC CHARACTERISTICS PEAK LOAD CAPABILITY Peak power capability supports short power peaks of dynamic loads like motors, relays, storage devices or computer booting sequences. In addition allowing faster charge of load sided capacitors and reliable circuit breaker operation. (measured @ T = 25°C, nom. V , full load and after warm-up unless otherwise stated) AMB IN
www.premiumpsu.com Powering Your Challenge 01-09-2025 CA-470-1 CLS-40 REGULATIONS Trim up 1 2 3 4 5 6 7 8 9 10 [%] Rup (E96) ≈ 499k 178k 124k 84k5 69k8 59k 46k4 41k2 34k8 30k9 [Ω] Rdown (E96) ≈ 3M32 1M4 1M 402k 576k 487k 402k 357k 301k 274k [Ω] Parameter Conditions Value Output Accuracy ±3.0% max. Line Regulation low line to high line, full load ±0.5% max. Load Regulation 0%-100% load 2.0% max. Transient Response 10-90% load, VIN= 16.8-138VDC 1.2VDC recovery time 40ms typ. OUTPUT VOLTAGE TRIMMING The output voltage of the CLS-40 can be trimmed between ±10% by using an external trim resistor. The values for the trim resistor are according to standard E96 values; therefore, the specified voltage may slightly vary. Resistor values may be calculated with the following equation: CLS-40-24 CLS-40-24 (measured @ T = 25°C, nom. V , full load and after warm-up unless otherwise stated) AMB IN
www.premiumpsu.com Powering Your Challenge 01-09-2025 CA-470-1 CLS-40 POWER GOOD Over Voltage Category (OVC) OVC II Over Current Protection (OCP) auto recovery VIN= 16.8-24VDC 1.84-4A VIN= 24-138VDC 2.5-4A Over Temperature Protection (OTP) auto recovery 105°C internal Class of Equipment Class I Isolation Coordination according to EN 50124-1:2018 VNOM= 250VDC Isolation Voltage (2) I/P to O/P 4.2kVDC I/P to case, OK contact to I/P, O/P and case 2.2kVDC O/P to case 1.5kVAC Isolation Resistance 300MΩ min. Isolation Capacitance 1200pF typ. Leakage Current 5µA Insulation Grade reinforced Internal Clearance I/P to O/P 5mm I/P to PE, O/P to PE 2.5mm Parameter Type Value Power OK LED VOUT= >21.6VDC green VOUT= <21.6VDC light off Open Collector VOUT= >21.6VDC OK= 5V/1mA VOUT= <21.6VDC NOK= 0V PROTECTIONS Parameter Type Value Internal Input Fuse T10A, slow blow type Short Circuit Protection (SCP) constant current mode, auto recovery >110%-135 of nom. output current Short Circuit Input Current VIN= 24VDC 0.3A VIN= 110VDC 0.15A Input Reverse Polarity Protection active protected -137.5VDC Over Voltage Protection (OVP) latch off 115-140% of nom VOUT (measured @ T = 25°C, nom. V , full load and after warm-up unless otherwise stated) AMB IN
www.premiumpsu.com Powering Your Challenge 01-09-2025 CA-470-1 CLS-40 Pollution Degree PD2 IP Rating IP20 Design Lifetime 20 years MTBF according to IEC 61709/ UTE C80-810 TAMB= +40°C 1950 x 10³ hours TAMB= +50°C 1400 x 10³ hours Useful Life Class according to EN50155:2018 (S1) L4 Note3: The board is protected on both sides with a protective / transparent / fluorescent / coating. The coating is compliant with class 2, according to IPC-A-610G: 2017 DERATING GRAPH ENVIRONMENTAL Parameter Conditions Value Operating Ambient Temperature Range according to EN 50155 operating temperature class OT4 and extended operating temperature class ST1 & ST2 without derating -40°C to +70°C without derating for 15 minutes -40°C to +85°C Maximum Baseplate Temperature +95°C Temperature Coefficient 0.2%/K Operating Altitude according to EN 50124-1:2018 5000m Operating Humidity non-condensing 95% RH max. Conformal Coating (3) according to EN 50155 Class PC2
www.premiumpsu.com Powering Your Challenge 01-09-2025 CA-470-1 CLS-40 Shock testing Half-sine shock, unit powered during test Vertical axis 30m/s² for 30ms Transverse axis 30m/s² for 30ms Longitudinal axis 50m/s² for 50ms Number of shocks: 18 (3x polarity for each axis) EN 61373 clause 10, class B Body mounted Functional random vibration test Random Vibration, unit powered during test Frequency range 5-150Hz with -6db/oct from 20 to 150Hz Vertical axis 1.01m/s² for 10min [ASD 0.0301(m/s²)²/Hz] Transverse axis 0.45m/s² 10min [ASD 0.006(m/s²)²/Hz] Longitudinal axis 0.7m/s² 10min [ASD 0.0144(m/s²)²/Hz] EN 61373 clause 8, class B Body mounted Fire Protection on Railway Vehicles EN45545-2 Hazard Level HL1 - HL3 Certificate Type (Safety) Standard Audio/video, information and communication technology equipment. Safety requirements IEC/EN62368- 1:2020+A11:2020 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment EN50124-1 Railway Applications - Electrical Equipment used on rolling stock EN50155 RoHS2 RoHS 2011/65/EU + AM2015/863 SAFETY & CERTIFICATIONS Parameter Conditions Value Low Temperature start-up test Temperature: -40°C Stabilization time 2h EN 60068-2-1 (Ad) Dry heat test Temperature: +70°C Continuous operational checks time 6h Cycle A Low temperature storage test Temperature: -40°C Low temperature exposition time 16h EN 60068-2-1 (Ab) Cyclic damp heat test Temperature: +70°C/+25°C Number of cycles: 2 Time 2x 24h EN 60068-2-30 (Db) Simulated long-life testing Random Vibration, unit not powered during test Frequency range 5-150Hz with -6db/oct from 20 to 150Hz Vertical axis 5.72m/s² for 5h [ASD 0.964(m/s²)²/Hz] Transverse axis 2.55m/s² for 5h [ASD 0.192(m/s²)²/Hz] Longitudinal axis 3.96m/s² for 5h [ASD 0.461(m/s²)²/Hz] EN 61373 clause 9, class B Body mounted ENVIRONMENTAL ( Railway standards)
www.premiumpsu.com Powering Your Challenge 01-09-2025 CA-470-1 CLS-40 Parameter Type Value Material case aluminum Dimension (LxWxH) 100.0 x 60.0 x 30.0mm 3.94 x 2.36 x 1.18 inch Weight 145g typ. 0.32 lbs DIMENSION & PHYSICAL CHARACTERISTICS EMC Compliance Conditions Standard / Criterion Railway applications - Electromagnetic compatibility EN50121-3-2:2016 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments EN61000-6-4:2007+A1:2011 ESD Electrostatic discharge immunity test Air: ±2, 4, 8kV Contact: ±2, 4, 8kV IEC61000-4-2:2009, Criteria A EN61000-4-2:2008, Criteria A Radiated, radio-frequency, electromagnetic field immunity test 20V/m (80-1000MHz) 10V/m (1000-2000MHz) 5V/m (2000-4000MHz) 3V/m (4000-6000MHz) IEC/EN61000-4-3:2006, Criteria A Fast Transient and Burst Immunity DC Power Port: ±2kV IEC/EN61000-4-4:2012, Criteria A Surge Immunity DC Power Port: ±0.5, 1kV line sym. DC Power Port: ±0.5, 1, 2kV line unsym. IEC/EN61000-4-5:2014, Criteria A Immunity to conducted disturbances, induced by radio-frequency fields 10Vr.m.s. (0.15-80MHz) IEC61000-4-6: 2016, Criteria A EN61000-4-6:2016, Criteria A Technische Regeln zur Elektromagnetischen Verträglichkeit: Nachweis der Funkverträglichkeit von Schienenfahrzeugen mit Bahnfunkdiensten Regelung Nr. EMV 06:2019
www.premiumpsu.com Powering Your Challenge 01-09-2025 CA-470-1 CLS-40 DIMENSION DRAWING ( mm) Accesories Notes Order qty. / device CODE Signals mating connector DEGSON 15EDGKNG-3.5-XXP-1Y-1000A(H) 1 2601-1118 ACCESORIES
www.premiumpsu.com Powering Your Challenge 01-09-2025 CA-470-1 CLS-40 INSTALLATION & APPLICATION PARALLEL OPERATION Here the example of three parallel connected units. For operation of the DC/DC converter the PE connection at the intended connection point as part of the overall EMC concept is mandatory. Natural air convection around the unit must be possible at any time and the temperature shall not be exceeded. The converter has to be installed with 4 x M4 screws and can be mounted in any mounting direction. All control and signal terminals have been tested and have passed the requirements according to the EN50121-3-2 regulations, nevertheless for installation conditions with cable lengths above 30m, maybe additional protection against disturbances will be necessary. INSTALLATION & APPLICATION MOUNTING INSTRUCTIONS
www.premiumpsu.com Powering Your Challenge 01-09-2025 CA-470-1 CLS-40 BLOCK DIAGRAM PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) cardboard box 120.0 x 40.0 x 100.0mm Packaging Quantity 1pc Storage Temperature Range -55°C to +85°C