CL1302D-L RFHIC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
Limiter-diode LNA CL1302D-L Korean Facilities : 82-31-250-5078 / rfsales@rfhic.com All specifications may change without notice US Facility : 919-677-8780 / sales@rfhicusa.com 1 / 5 Version 1.1 Product Features Applications
- GaAs p-HEMT chip on board
- Limiter–diode insertion
- High Maximum Input Power(+30dBm)
- No matching circuit needed
- Single Supply V oltage (+5V)
- Surface Mount Hybrid Type
- Tape & Reel Packaging
- Small Size, High Heatsink
- Alumina Substrate
- Pb Free / RoHS Standard
- WiMAX, LTE
- Radar
- Repeater
- Base Station
- RF Sub-Systems
Description
This LNA family is a high gain, ultra low noise amplifier. Electrical Specifications PARAMETER UNIT MIN TYP MAX Frequency Range MHz 1200 - 1400 Small Signal Gain (S21) dB - 18 - Gain Flatness dB - ± 0.5 - Input Return Loss (S11) dB - -12 - Output Return Loss (S22) dB - -11 - 1dB Compression Point (P1dB) dBm 18 20 - Output 3rd Order Intercept Point (OIP3) (TYP.) dBm 30 33 - Noise Figure (TYP.) dB - 0.7 1.0 RF Input Power (for 12 hours) dBm - - 30 DC Supply Current (Vdc=+5V) mA - 100 120 Test Condition Fc=① 1300MHz, Supply Voltage = +5V, 50ohm system, Ta = 25℃ ② OIP3 is measured with two tones, at an output power of + 0dBm/tone separated by 1MHz. Absolute Maximum Ratings PARAMETER UNIT RATING REMARK Device Voltage V 8 - RF Input Power dBm 30 - Operating Temperature ℃ -40 ~ 85 - Storage Temperature ℃ -50 ~ 125 - Note Operation of this device in excess of any one of these parameters may cause permanent damage. Package Type : CP-16A
Limiter-diode LNA CL1302D-L Korean Facilities : 82-31-250-5078 / rfsales@rfhic.com All specifications may change without notice US Facility : 919-677-8780 / sales@rfhicusa.com 2 / 5 Version 1.1 Functional Diagram Application Circuit ESD Protection Gallium Arsenide Integrated Circuits are sensitive to electrostat ic discharge (ESD) and can be damaged by static electricity. P roper ESD control techniques should be used when handling these devices. Some of the precautions recommended are; - Person at a workbench should be earthed via a wrist strap and a resistor. - All mains-powered equipment should be connected to the mains via an earth-leakage switch. - Equipment cases should be grounded. - Relative humidity should be ma intained between 40% and 50%. - An ionizer is recommended. - Keep static materials, such as plastic envelopes and plastic trays etc. away from the workbench.
Limiter-diode LNA CL1302D-L Korean Facilities : 82-31-250-5078 / rfsales@rfhic.com All specifications may change without notice US Facility : 919-677-8780 / sales@rfhicusa.com 3 / 5 Version 1.1 CL1302D-L S-Parameter OIP3 Noise Figure
Limiter-diode LNA CL1302D-L Korean Facilities : 82-31-250-5078 / rfsales@rfhic.com All specifications may change without notice US Facility : 919-677-8780 / sales@rfhicusa.com 4 / 5 Version 1.1 Package Dimensions (Type: CP-16A) * Unit: mm[inch] | Tolerance ±0.15[.006] ▲ T o p V i e w ▲ S i d e V i e w ▲ Bottom View Pin Description Pin No Function Pin No Function
1 GND 4 GND
2 Input 5 Output
3 GND 6 Vcc
Recommended Pattern Recommended Mounting Configuration * Mounting Configuration Notes 1. Ground / thermal via holes are critical for the proper performance of this device. 2. Add as much copper as possible to inner and outer layers near the part to ensure optimal thermal performance. 3. Mounting screws can be added near the part to fasten the board to a heatsink. Ensure that the ground / thermal via hole region contacts the heatsink. 4. Do not put solder mask on the backside of the PCB in the region where the board contacts the heatsink. 5. RF trace width depends upon the PCB material and construction. 6. Use 1 oz. Copper minimum.
Limiter-diode LNA CL1302D-L Korean Facilities : 82-31-250-5078 / rfsales@rfhic.com All specifications may change without notice US Facility : 919-677-8780 / sales@rfhicusa.com 5 / 5 Version 1.1
Revision History
Part Number Release Date Version Modification Data Sheet Status CL1302D-L 2012.10.19 1.1 New datasheet format - CL1302D-L 2012.2.18 1.0 Initial Release - RFHIC Corporation reserves the right to make changes to any products herein or to discontinue any product at any time without notice. While product specifications have been thoroughly examined for reliability, RFHIC Corporation strongly recommends buyers to verify that the information they are using is accurate before ordering. RFHIC Corporation does not assume any liability for the suitability of its products for any particular purpose, and disclaims any and all liability, including wi thout limitation consequential or incidental damages. RFHIC products are not intended for use in life support equipment or application where malfunction of the product can be expect ed to result in personal injury or death. Buyer uses or sells such products for any such unintended or unauthorized application, buyer shall indemnify, protect and hold RFHIC Corporation and its directors, officers, stockholders, employees, representatives and distributors harmless against any and all claims arising out of such unauthorized use. Sales, inquiries and support should be directed to the local authorized geographic distributor for RFHIC Corporation. For customers in the US, please contact the US Sales Team at 919- 677-8780. For all other inquiries, please contact the International Sales Team at 82-31-250-5078.