Applications
- Architectural and Specialty
- Street Lighting
- Parking Lot and Area Lighting
- Tunnel Lighting Features:
- High lumen output and efficacy typical
- Over 11,000 lm, 119 LPW @ 3000K, 25ºC
- Over 12,000 lm, 130 LPW @ 5000K, 25ºC
- CCT range 2700K, 3000K, 3500K, 4000K, 5000K and 6500K
- 80 or 90 CRI min. up to 95 min. in warm white
- 3 SDCM color binning accuracy
- Excellent optical emission uniformity and color over angle consistency
- Exceptional long term color stability
- Superior thermal conductivity for uniform heat spreading
- Environmentally friendly: RoHS and REACh compliant
- UL recognized, file # E465703. Table of Contents Part number nomenclature .4 Ordering part number and flux Operating Characteristics .. 7 Optical and Electrical Character- Mechanical Dimensions .. 10 Packaging Information ... 11 PDS-002481 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved CHM-27 COB Arrays White LED CHM-27 Product Datasheet
PDS-002481 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved CHM-27 Product Datasheet Reliability Designed from the ground up, the Luminus COB LED is one of the most reliable light sources in the world today. Having passed a rigorous suite of environmental and mechanical stress tests, including mechanical shock, vibration, temperature cycling and humidity. Only then are the devices qualified for use in a wide range of lighting application including some of the most demanding commercial applications. Delivered with fully qualified LM80 test data and TM21 lifetime results that certify lumen maintenance at 35,000 hours or more, Luminus COB LEDs are ready for the toughest challenges. UL Recognized Compliance Luminus COB arrays are tested in accordance with ANSI/UL 8750 to ensure safe operation for their intended applications. REACh & RoHS Compliance All LED products manufactured by Luminus are REACh and RoHS compliant and free of hazardous materials, including lead and mercury. Traceability Each Luminus COB LED is marked with a 2D bar code that contains a unique serial number. With this serial number, Luminus has the ability to provide customers with actual test data measurements for a specific LED. In addition, the 2D bar code is linked to manufacturing date codes that enables traceability of production processes and materials. Testing Temperature Luminus COB products are measured at temperatures typical for the LED operating in the fixture. Each device is tested at 85ºC junction temperature eliminating the need to scale data sheet specifications to real world situations. Chromaticity Bin Range Chromaticity binning delivers color consistency for every order. Standard products are delivered with a 3-step MacAdam ellipse. This ensures color performance matching in the application. For the most demanding application, Luminus is one of only a few companies that can provide a 2-step ellipse bin. These tightly controlled, small distribution bins provide customers predictable, repeatable colors. Every Luminus LED is fully tested to ensure it meets the high quality standards customers have come to expect from Luminus’ products. Technology Overview Luminus Chip-on-Board (COB) LED series offers a complete lighting class solution designed for high performance illumination applications. The selection covers a wide lumen range from less than 400lm to over 10,000lm, all major color temperatures and can deliver color rendering greater than 97 at 2700K and 3000K and R9 equal to 95. These breakthroughs allow illumination engineers and designers to develop lighting solutions with maximum efficacy, brightness and overall quality. Understanding Luminus COB LED Test Specifications
PDS-002481 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved CHM-27 Product Datasheet *Note: Luminus maintains a +/- 0.005 tolerance on chromaticity (CIEx and CIEy) measurements. The following tables describe the ANSI bin center points, the orientation angle for the MacAdam ellipse (θ °), and the maximum radii for the ellipses. The ANSI Bin is provided for reference. CHM-27 White Chromaticity Bins CCT Center Point Angle 3-step Bin 5-step Bin CIEx CIEy θ (°) a b a b 3500K 0.4073 0.3917 54 0.00927 0.00414 0.3 0.32 0.34 0.36 0.38 0.4 0.42 0.44 0.46 CIE y CIE x 2700K 3000K 3500K 4000K 5000K Black Body ANSI C78.377-2008 2-step Ellipse 3-step Ellipse 5-step Ellipse 6500K 0.3 0.32 0.34 0.36 0.38 0.4 0.42 0.44 0.46 CIE y CIE x 2700K 3000K 3500K 4000K 5000K Black Body ANSI C78.377-2008 3-step Ellipse 5-step Ellipse 6500K Chromaticity Bin Structure Chromaticity Bins: 1931 CIE Curve
PDS-002481 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved Note 1: NN nomenclature corresponds to the following: 27 = 2700K 30 = 3000K 35 = 3500K 40 = 4000K 50 = 5000K 65 = 6500K Note 2: AA is standard package configurator AB is an alternative Product Family Light Emitting Surface Diameter Color Temperature Color Render- ing Index (CRI) Voltage (typical) Package Configurator Flux Bin Chromaticity Bin CHM: Chip on Board 26.5: LES Diameter (mm) Color See Note 1 Below CRI See Table Below Volts AA00 (Basic package) Lumens See page 3 for bins CHM 27 NN XX 36 QQPP FG W CHM-27 Product Datasheet Product Ordering and Shipping Part Number Nomenclature All CHM-27 products are packaged and labeled with part numbers as outlined in the table on page 5. When shipped, each package will contain only a single flux and chromaticity bin. The part number designation is as follows: Color Temperature, CRI and R9 Values Color Temperatures XX Value CRI R9 4000K, 5000K, 6500K 70 >70 - 2700K, 3000K, 3500K, 4000K, 5000K, 6500K 80 >80 >0 2700K, 3000K, 3500K, 4000K 90 >90 >50 2700K, 3000K 95 >95 >90 Note: Luminus part numbers may be accompanied by prefixes or suffixes. The most common is the “Rev01” suffix indicating a part is fully released and carries a full warranty. These additional characters may appear on shipping labels, packing slips and invoices. In all cases the basic part number described above will always be included.
PDS-002481 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved The following tables describe products with typical flux and minimum flux measured at 2,700mA and specified at Tj = 85ºC. The values at 25ºC are calculated and shown for reference only. CHM-27 Product Datasheet CHM-27 Part Numbers (AA00) CCT Output Flux (lm) Reference Color Rendering Index Ordering Part Number Typ. (85ºC) Min. (85ºC) Typ. (calculated) (25ºC) CRI (min.) 3-step MacAdam Ellipse 2700K 9,730 9,240 10,700 80 CHM-27-27-80-36-AA00-F2-3 7,585 7,206 8,345 90 CHM-27-27-90-36-AA00-F2-3 7,140 6,785 7,855 95 CHM-27-27-95-36-AA00-F2-3 3000K 10,270 9,755 11,300 80 CHM-27-30-80-36-AA00-F2-3 8,750 8,310 9,625 90 CHM-27-30-90-36-AA00-F2-3 8,085 7,680 8,895 95 CHM-27-30-95-36-AA00-F2-3 3500K 10,620 10,090 11,685 80 CHM-27-35-80-36-AA00-F2-3 9,155 8,700 10,070 90 CHM-27-35-90-36-AA00-F2-3 4000K 11,535 10,955 12,690 70 CHM-27-40-70-36-AA00-F2-3 10,985 10,435 12,085 80 CHM-27-40-80-36-AA00-F2-3 9,470 9,000 10,420 90 CHM-27-40-90-36-AA00-F2-3 CCT Output Flux (lm) Reference Color Rendering Index Part Number Typ. (85ºC) Min.. (85ºC) Typ. (calculated) (25ºC) CRI (min.) 5-step MacAdam Ellipse 3-step MacAdam Ellipse 5000K 11,810 11,220 12,990 70 CHM-27-50-70-36-AA00-F2-5 CHM-27-50-70-36-AA00-F2-3 11,430 10,860 12,575 80 CHM-27-50-80-36-AA00-F2-5 CHM-27-50-80-36-AA00-F2-3 6500K 11,760 11,170 12,935 70 CHM-27-65-70-36-AA00-F2-5 CHM-27-65-70-36-AA00-F2-3 11,200 10,640 12,320 80 CHM-27-65-80-36-AA00-F2-5 CHM-27-65-80-36-AA00-F2-3 *Note: Luminus maintains a +/- 6% tolerance on flux measurements. Luminus maintains a +/- 2% tolerance on CRI measurements.
PDS-002481 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved The following tables describe products with typical flux and minimum flux measured at 2,700mA and specified at Tj = 85ºC. The values at 25ºC are calculated and shown for reference only. CHM-27 Product Datasheet CHM-27 Part Numbers (AB00) CCT Output Flux (lm) Reference Color Rendering Index Ordering Part Number Typ. (85ºC) Min. (85ºC) Typ. (calculated) (25ºC) CRI (min.) 3-step MacAdam Ellipse 2700K 9,730 9,240 10,700 80 CHM-27-27-80-36-AB00-F2-3 7,585 7,206 8,345 90 CHM-27-27-90-36-AB00-F2-3 7,140 6,785 7,855 95 CHM-27-27-95-36-AB00-F2-3 3000K 10,270 9,755 11,300 80 CHM-27-30-80-36-AB00-F2-3 8,750 8,310 9,625 90 CHM-27-30-90-36-AB00-F2-3 8,085 7,680 8,895 95 CHM-27-30-95-36-AB00-F2-3 3500K 10,620 10,090 11,685 80 CHM-27-35-80-36-AB00-F2-3 9,155 8,700 10,070 90 CHM-27-35-90-36-AB00-F2-3 4000K 11,535 10,955 12,690 70 CHM-27-40-70-36-AB00-F2-3 10,985 10,435 12,085 80 CHM-27-40-80-36-AB00-F2-3 9,470 9,000 10,420 90 CHM-27-40-90-36-AB00-F2-3 CCT Output Flux (lm) Reference Color Rendering Index Part Number Typ. (85ºC) Min.. (85ºC) Typ. (calculated) (25ºC) CRI (min.) 5-step MacAdam Ellipse 3-step MacAdam Ellipse 5000K 11,810 11,220 12,990 70 CHM-27-50-70-36-AB00-F2-5 CHM-27-50-70-36-AB00-F2-3 11,430 10,860 12,575 80 CHM-27-50-80-36-AB00-F2-5 CHM-27-50-80-36-AB00-F2-3 6500K 11,760 11,170 12,935 70 CHM-27-65-70-36-AB00-F2-5 CHM-27-65-70-36-AB00-F2-3 11,200 10,640 12,320 80 CHM-27-65-80-36-AB00-F2-5 CHM-27-65-80-36-AB00-F2-3 *Note: Luminus maintains a +/- 6% tolerance on flux measurements. Luminus maintains a +/- 2% tolerance on CRI measurements.
CHM-27 Operating Characteristics1 Note 1: Ratings are based on operation at a constant junction temperature Tj = 85ºC. Note 2: To prevent damage refer to operating conditions and derating curves for appropriate maximum operating conditions Note 3: Forward voltage is rated at typical forward current. For voltage at different forward currents, refer to the voltage versus current performance graphs. Note 4: COB LEDs are designed for operation to a minimum of 20% of the typical forward current value. Operation at currents lower than this value will not harm the device but may result in uneven light emission across the LES surface. Note 5: Luminus retains the right to change any specifications without prior notice. Please refer to the company web site for the latest data sheet revision Note 6: Caution must be taken not to stare at the light emitted from these LEDs. Under special circumstances, the high intensity could damage the eye. PDS-002481 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved CHM-27 Product Datasheet Optical and Electrical Characteristics Parameter Symbol Minimum Typical Maximum Unit Forward Current2 If 2,640 4,000 mA Forward Voltage3 Vf 31.5 35 37.5 V Power 92.4 146 W Operating Case Temperature4 Tc 105 ºC Light Emitting Surface Diameter LES 26.5 mm Thermal Resistance (junction-to-case) Qjc 0.16 ºC/W Junction Temperature Tj 140 ºC Viewing Angle 120 Degree
Relative Output Flux vs. Forward Current @ 85ºC Forward Current vs. Forward Voltage @ 85ºC CHM-27 Product Datasheet PDS-002481 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved CHM-27 Optical & Electrical Characteristics Relative Output Flux vs. Junction Temperature Change in Voltage vs. Junction Temperature Change in CIEx vs. Junction Temp. (3000K, 80CRI) Change in CIEy vs. Junction Temp. (3000K, 80CRI) 0.0% 20.0% 40.0% 60.0% 80.0% 100.0% 120.0% 5 15 25 35 45 55 65 75 85 95 105 Relative Luminous Flux Junction Temperature (ºC) 5 15 25 35 45 55 65 75 85 95 105 Forward Voltage (V) Junction Temperature (ºC) -0.02 -0.01 0.01 0.02 5 15 25 35 45 55 65 75 85 95 105 ΔCIEx Junction Temperature (ºC) -0.02 -0.01 0.01 0.02 5 15 25 35 45 55 65 75 85 95 105 ΔCIEy Junction Temperature (ºC) 20% 40% 60% 80% 100% 120% 140% 160% 1000 1500 2000 2500 3000 3500 4000 Relative Luminous Flux Forward Current (mA) 1000 1500 2000 2500 3000 3500 4000 33 33.5 34 34.5 35 35.5 36 36.5 Forward Current (mA) Forward Voltage (V)
PDS-002481 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved CHM-27 Product Datasheet Typical Spectrum CHM-27 Optical & Electrical Characteristics -20.00% 0.00% 20.00% 40.00% 60.00% 80.00% 100.00% 120.00% 400 450 500 550 600 650 700 750 800 Relative Intensity Wavelength (nm) Warm White Neutral White Cool White 3000K-90CRI 3000K-97CRI Typical Polar Radiation Pattern Typical Angular Radiation Pattern 20% 40% 60% 80% 100% 120% -80 -60 -40 -20 0 20 40 60 80 Relative Intensity (%) Anglular Displacement (Degrees)
PDS-002481 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved CHM-27 Product Datasheet 31.50±0.25 1.240±.010 31.50±0.25 1.240±.010 27.90 1.098 27.90 1.098 28.00 1.102 RING O.D. 26.50 1.043 LES 2X 2.40 .094 2X 2.40 .094 2X 3.26 .128 2X 3.26 .128 2X 13.95 .549 HOLES 2X 13.95 .549 HOLES 1.20 .047 TcPOINT 1.37 .054 0.87±0.15 .034±.006 0.50±0.10 .020±.004 RING HEIGHT Mechanical Dimensions (AA00) Mechanical Dimensions (AB00) 27.90 1.098 6XR 0.20 .008 2XR 1.60 .063 4XR 0.50 .020 2X 2.40 .094 2X 3.02 .119 2X 2.40 .0942X 3.02 .119 31.50±0.25 1.240±.010 31.50±0.25 1.240±.010 27.90 1.098 1.20 .047 TcPOINT 28.00 1.102 RING O.D. 2X 13.35 .526 26.50 1.043 LES 2X 13.95 .549 HOLES 2X 13.95 .549 HOLES 2X 13.35 .526 2X 2.55 .100 0.87±0.15 .034±.006 1.37 .054 0.50±0.10 .020±.004 RING HEIGHT
PDS-002481 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved CHM-27 Product Datasheet Shipping Container Label 100 pcs per box Each bag is boxed for easier storage/ stacking Trays are sealed in an anti-static bag 20 pcs per tray 5 trays are stacked together with separate cover Luminus Label Model: Luminus Devices Inc XXXXXX-XX-XX (Manufacturer Part Number & Bin Kits) RoHS Compliant XXX-XX-XX-XX-XX-XXXX-XX-X (Customer Part Number) Rev XX Bar code XXXXXXXXXXXXXX (Box ID) Qty: XX Bar code Bar code Bar code
(Part #) Product Datasheet PDS-002481 Rev 04 © 2018 Luminus Devices, Inc. - All Rights Reserved CHM-27 Product Datasheet General Handling Devices are made to be lifted or carried with tweezers on two adjacent corners opposite the contact pads. At no time should the devices be handled by or should anything come in contact with the light emitting surface (LES) area. This area includes the yellow colored circular area and the ring surrounding it. There are electrical connections under the LES which if damaged will cause the device to fail. In addition, the ring frame itself should not be used for moving, lifting or carrying the device. Also do not attach any optics or mechanical holders to the ring as it is not capable to handle the mechanical stress. Static Electricity Luminus COBs are electronic devices which can be damaged by electrostatic discharge (ESD). Please use appropriate measures to assure the devices do not experience ESD during their handling and or storage. ESD protection guidelines should be used at all times when working with Luminus COBs. Storage: Luminus products are delivered in ESD shielded bags and should be stored in these bags until used. Assembly: Individuals handling Luminus COBs during assembly should be trained in ESD protection practices. Assemblers should maintain constant conductive contact with a path to ground by means of a wrist strap, ankle straps, mat or other ESD protection system. Transporting: When transporting the devices from one assembly area to another, ESD shielded carts and carriers should be used. Electrical Contact Luminus COBs are designed with contact pads on their top surface. These pads are clearly marked with + and – polarity. Wires can be soldered to the contact pads for electrical connections or other solderless connector products are available. If wires are being soldered to the COB product, we recommend attaching these wires prior to mounting the devices to a heat sink. Please contact Luminus for specific recommendations on how to solder wires if not familiar with the standard practice. Luminus can also offer design recommendations for jigs to allow easily soldering multiple products in rapid succession. Chemical Compatibility The resin material used to form the LES can getter hydrocarbons from the surrounding environment. As a results, certain chemical compounds are not recommended for use with the Luminus products. Use of these compounds can cause damage to the light output of the device and may permanently damage the device. Please refer to www.luminus.com for a list of the compounds not recommended for use with the Luminus COB products. Thermal Interface Material (TIM) Proper thermal management is critical for successful operation of any LED system. Excess operating temperature can reduce the light output of the device. And excessive heating can cause permanent damage to the device. Proper TIM material is a crucial component for effective heat transfer away from the LED during normal operation. Please refer to www.luminus.com for specific recommendations for TIM solutions. Handling Notes for Luminus COBs Luminus products are designed for robust performance in general lighting application. However, care must be taken when handling and assembling the LEDs into their fixtures. To avoid damaging Luminus COBs please follow these guide lines. The following is an overview of the application notes detailing some of the practices to follow when working with these devices. More detailed information is available on the Luminus web site at www.luminus.com.