CD34CNFLF CARLOGAVAZZI | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 9

Technical content

Carlo Gavazzi Industri A/S CD34CNFLFxxx CD34CNFLFxxx ENG 03/08/2020 Capacitive sensor, Foreground Suppression

Description

The CD34.. capacitive sensor is designed for detecting water-based (conductive) liquids through a non-metallic container wall, and it automatically adapts to various thicknesses of plastic or glass walls. The universal mounting brackets allow the sensor to be fixed on various tubes or containers. Strong, compact housing with IP69K ratings and ECOLAB approval for wash-down applications. The sensor will function out of the box in most applications, and teach-in capabilities are available for adapting the sensor to more challenging applications. Main features

  • Compact housing
  • Supply voltage: 10 to 30 VDC
  • Output: 100 mA, NPN or PNP preset
  • Make or break switching function
  • LED indication for output and power ON
  • Protection: reverse polarity, short circuit and transients
  • Cable and pigtail M8 plug versions
  • Excellent EMC performance
  • IP65, IP66, IP67, IP68 and IP69K for hose-down

applications

  • cULus
  • Ecolab Main functions
  • Detection of water-based fluids inside a container or tube without direct contact with the fluids.
  • The sensor detects the liquids reliably while compensating for residue film, moisture or foam build-up from liquids such as water, milk, body fluids (blood), acid- or alkaline solutions with conductivity as high as 50 mS/cm inside or outside the container wall.
  • Flexible and fast universal mounting bracket.
  • The sensing principle detects only the level of the liquids while ignoring foam, film or build-up that would cause standard capacitive sensors to detect faultily.

Carlo Gavazzi Industri A/S CD34CNFLFxxx CD34CNFLFxxx ENG 03/08/2020 References Product selection key CD34CNFLF Enter the code option instead of Code Option Description C - Capacitive sensor D - Rectangular housing 34 - Length of housing C - Plastic housing N - Neutral F - Flush mounting L - Liquid level F Foreground suppression N NPN P PNP O N.O. C N.C. P2 2 m PVC Cable T5 Pigtail PVC Type selection Connec- tion Output Code Cable NPN, N.O. CD34CNFLFNOP2 NPN, N.C. CD34CNFLFNCP2 PNP, N.O. CD34CNFLFPOP2 PNP, N.C. CD34CNFLFPCP2 Pigtail NPN, N.O. CD34CNFLFNOT5 NPN, N.C. CD34CNFLFNCT5 PNP, N.O. CD34CNFLFPOT5 PNP, N.C. CD34CNFLFPCT5 Mounting bracket ACD34-MB01

Carlo Gavazzi Industri A/S CD34CNFLFxxx CD34CNFLFxxx ENG 03/08/2020 Structure AB C E AB C E D E Fig. 1 Cable Fig. 2 Pigtail Fig. 3 Sensing surface Element Component Function A LED Green LED: Power ON B LED Yellow LED: Output C 2 M3 Fixing holes for sensor mounting D Sensing surface E Recessed area for cable strips, max. 5 mm wide Sensing Accuracy Temperature drift Factory settings ≤ 20% (-25°C... +80°C) Manual teach ≤ 20% (-25°C... +60°C) Detection Pipes diameter Min. Ø 8 mm Out of the box: wall thickness Plastic 0.5 - 6 mm (non-conductive plastic wall) Glass 0.5 - 4 mm (non-conductive glass wall) With manual setup: wall thickness Up to 10 mm plastic wall (best case) Up to 10 mm glass wall (best case) Detection liquids Water-based liquids such as water, milk, syrup, honey, milkshakes, lubricates, acids, alkaline fluids, body fluids and other high-conductive liquids (up to 50 mS)

Carlo Gavazzi Industri A/S CD34CNFLFxxx CD34CNFLFxxx ENG 03/08/2020

Features

Rated operational voltage (UB) 10 ... 30 VDC (ripple included) Ripple (Urpp) ≤ 10% No load supply current (Io) ≤ 13 mA Power-ON delay (tv) < 300 ms Outputs Output functions NPN or PNP by sensor type Output switching function N.O. and N.C by sensor type Rated operational current (Ie) ≤ 100 mA OFF-state current(Ir) PNP and NPN 50 μA Voltage drop (Ud) < 1 .5 V Protection Short circuit, reverse polarity and transients Utilization category DC-1 Control of resistive loads and solid-state loads with optical isolation DC-13 Control of electromagnets Load capacitance max at (Ue) 330 nF Operation diagram Tv = Power-ON delay Power supply ON Target Present Break output (N.C.) ON Tv Make output (N.O.) ON Tv Response times Operating frequency (f) ≤ 10 Hz Response times ≤ 50 ms OFF-ON (tON) ≤ 50 ms ON-OFF (tOFF)

Carlo Gavazzi Industri A/S CD34CNFLFxxx CD34CNFLFxxx ENG 03/08/2020 Indication Normal mode Green LED Yellow LED Power Output OFF OFF OFF OFF ON OFF ON OFF ON ON ON ON Output short circuit Green LED Yellow LED Output OFF Flashes 4Hz Yellow LED flashes minimum 1 sec. Teach by wire Out of the box (Factory settings): Typically, the sensor can be used without any additional calibration; it is designed to work with plastic tank walls of approximately 0,5 to 6 mm in thickness and glass walls of approximately 0,5 to 4 mm in thickness. It is important that the glass or plastic is nonconductive. Calibration: If the factory settings are insufficient, the sensor is teachable to either Full or Empty. Calibration Full: The sensor switch point is set below the actual detection value to ensure that slight changes in the application will not affect the sensing performance. In most applications, the full calibration on a full tank or tube will be sufficient. In critical applications with large variations in media type and temperature, it can be an advantage to teach the Full level with approximately 50 % of the active sensing surface covered. Full calibration procedure:

  • Connect teach wire to V+ for 2 - 7 seconds
  • The green LED flashes 1 imp. per sec. and the yellow LED is OFF
  • After successful calibration, the yellow LED flashes 3 times (with 1 Hz) Calibration Empty: The sensor switch point is set above the actual detection value to ensure that slight changes in the application will not affect the sensing performance. In most applications, the Empty calibration on an empty tank or tube will be sufficient. In critical applications with a high amount of residue film, moisture or foam build-up, an Empty calibration can be performed with the build-up present. Empty calibration procedure:
  • Connect teach wire to V+ for 7 - 12 seconds
  • The green LED flashes 1 imp. per sec. and the yellow LED is ON
  • After successful calibration, the yellow LED flashes 3 times (with 1 Hz) Cancel calibration procedure:
  • Keep the teach wire connected to V+ for more than 14 seconds to abort teach procedure. The switch points will remain unchanged.
  • The green LED is off and the yellow LED flashes (4 Hz)

Carlo Gavazzi Industri A/S CD34CNFLFxxx CD34CNFLFxxx ENG 03/08/2020 Green LED Yellow LED Output Flashes 1Hz OFF Full calibration (2-7 sec) Flashes 1Hz ON Empty calibration (7-12 sec) NA Flashes 3 times 1Hz Succesful "full calibration" NA Flashes 3 times 1Hz Succesful "empty calibration" NA Flashes 10 times 4Hz Unsuccesful calibration (cancelled or error) (>12 sec) Environmental Ambient humidity range 35% ... 100% Operating 35% ... 100% Storage Vibration 10 ...150 Hz, 1.0 mm/15 g EN 60068-2-6 Shock 30 gnn / 11ms, 6 pos, 6 neg per axis EN60068-2-27 Drop test 2 x 1 m and 100 x 0.5 m EN 60068-2-31 Rated insulation voltage (Ui) 75 VDC Dielectric insulation voltage ≥ 1250 VAC rms 50/60 Hz for 1 min. Rated impulse withstand voltage 1 kV 1.2/50 µs Pollution degree 3 ICE60664, ICE60664A, EN60947-1 Overvoltage category III IEC60664; EN60947-1 Degree of protection IP65, IP66, IP67, IP68 @ 1.3m and 24 h IEC60539; EN60947-1 IP69K DIN 40050-9 NEMA Enclosure Types 1, 2, 4, 4x, 5, 12 NEMA 250 EMC Electrostatic discharge immunity test ± 8 kV @ air discharge or ± 4 kV @ contact discharge IEC 61000-4-2, EN60947-1 Electromagnetic field immunity 3 V/m IEC 61000-4-3, EN60947-1 Fast transient immunity 2 kV IEC 61000-4-4, EN60947-1 Wire-conducted noise 3 V IEC 61000-4-6, EN60947-1 Power frequency magnetic field im- munity test 30 A/m IEC 61000-4-8, EN60947-1

Carlo Gavazzi Industri A/S CD34CNFLFxxx CD34CNFLFxxx ENG 03/08/2020 Mechanics/electronics Connection Cable 2 m, 4-wire 4 x 0.14 mm2, Ø = 3.4 mm, PVC Pigtail 0.3 m, M8, 4-pin, male Wiring Teach-inI <100mALOAD +1BN 3BU 2WH 4BK Teach-in I <100mALOAD +1BN 3BU 4BK 2WH Fig. 4 PNP NO Fig. 5 NPN NO Teach-inI <100mALOAD +1BN 3BU 2WH 4BK Teach-in I <100mALOAD +1BN 3BU 4BK 2WH Fig. 6 PNP NC Fig. 7 NPN NC NOTE: White wire connected to GND (3BU) wire when not in use BN WH BK BU Brown White Black Blue Housing Body PC/PBT Mounting bracket PC/PBT Light guides Polyamid TR55, Transparent Pigtail Black TPU (Thermoplastic polyurethane), Stainless steel AISI 304 Dimensions 8 x 16 x 34 mm Weight ≤ 60 g Cable version ≤ 30 g Pigtail version Tightening torque, Sensor 0.2 Nm Tightening torque, Mounting bracket 0.2 Nm Screw size M3 (with lowered head)

Carlo Gavazzi Industri A/S CD34CNFLFxxx CD34CNFLFxxx ENG 03/08/2020 Dimensions (mm) 16 8 1.1 16.3 10 3 3.6 6.6 3.2 Fig. 8 CD34 10.5 10.5 52.85 73.85 7.626 Fig. 9 Mounting bracket (ACD34-MB01)

Carlo Gavazzi Industri A/S CD34CNFLFxxx CD34CNFLFxxx ENG 03/08/2020 Compatibility and conformity Approvals and markings General reference Sensor designed according to EN60947-5-2 and EN60947-1 MTTFd 246 years @ 40°C (+104°F) EN ISO 13849-1, SN 29500 CE-marking Approvals (UL508 + C22.2) Other Approvals Topax 56, Topaz AC1, Topaz MD3, Topaz CL1, Topactiv OKTO, P3-hypochloran Delivery contents and accessories Delivery contents

  • Capacitive sensor: CD34CNFLF…
  • Mounting bracket: ACD34-MB01
  • 2 x Foam pads 3 mm (for pipe mounting)
  • 2 x Adhesive pads 1 mm (for screwless surface mounting)
  • Quick installation guide Further information Information Where to find it QR Manual http://cga.pub/?262c4a COPYRIGHT ©2020 Content subject to change. Download the PDF: www.gavazziautomation.com