CCH400_17 XPPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

  1. Safety approvals cover frequency 47-6 3 H z. AC-DC Specification 400/600 Watts
  • Baseplate Cooled
  • High Efficiency up to 90%
  • -40 °C to +85 °C Operation
  • Industrial & MIL-STD461E EMC Compliance
  • Power Fail, Inhibit, Overtemp & Current Share
  • 5V Standby Output
  • 3 Year Warranty CCH400-600 Series Input Input Voltage • 90-26 4 VAC Input Frequency • 47-400 H z (1) Input C urrent • CCH 400: 4.3 /2.1 A typ. at 115/23 0 VAC, CCH 6 00: 6 .3 /3 .1 A typ. at 115/23 0 VAC, full load Inrush C urrent • 6 0 A m ax at 23 0 VAC, 25 °C cold start Pow er Factor • > 0.9 Earth Leakage C urrent • 0.7/1.1 m A at 115/23 0 VAC at 6 0/50 H z Input Protection • Internal F10 A/250 V fuse Output O utput Voltage • 12-48 VD C O utput Voltage Trim • ±10% Initial Set Accuracy • ±1% V1, ±3 % V2 M inim um Load • N o m inim um load required Start U p D elay • T ypically 1 s Start U p Rise Tim e • 50 m s typical H old U p Tim e • 20 m s m in D rift • ±0.2% after 20 m in w arm up Line Regulation • ±0.5% m ax Load Regulation • ±1% V1, ±5% V2 m ax O ver/U ndershoot • 1% typical Transient Response • 4% m ax. deviation, recovery to w ithin 1% in 500 µs for a 50-75-50% load change Ripple & N oise • T ypically 1% pk-pk V1, V2 2% ,

20 M H z bandw idth

O vervoltage Protection • 110-140% Vnom , recycle input to reset O verload Protection • 105-140% V1 only Short C ircuit Protection • Continuous, approxim ately constant current Tem perature • 0.05% /˚C C oefficient O vertem p. Protection • Fitted Rem ote Sense • Com pensates for 0.5 V total voltage drop Rem ote O n/O ff • U ncom m itted isolated optocoupler diode, pow ered diode inhibits V1 xppow er.com General Efficiency • 8 9% typical Isolation • 3 000 VAC Input to O utput,

1500 VAC Input to G round,

500 VD C O utput to G round

Sw itching Frequency • 3 0-3 3 3 kH z PFC, 51.1 kH z m ain and 13 8 kH z standby converter Signals • Pow er Fail, Inhibit, Current Share, O vertem perature W arning and 5 V Standby M TBF • 3 00 kH rs to M IL-H D B K-217F at 25 °C, G B Environmental O perating Tem perature • -40 ˚C to +8 5 ˚C baseplate, see therm al considerations C ooling • B aseplate, conduction cooling O perating H um idity • 95% R H , non-condensing Storage Tem perature • -40 ˚C to +8 5 ˚C O perating Altitude • 3 000 m Shock • M IL-STD 8 10F Clause 516 .5 proc 1 Vibration • M IL-STD 8 10F figure 514.5C-17 EMC & Safety Low Voltage PSU EM C • EN 6 1204-3 , high severity level Em issions • EN 55022 level B conducted, level A radiated, M IL-STD 46 1D -F , CE102 H arm onic C urrents • EN 6 1000-3 -2, class A Voltage Flicker • EN 6 1000-3 -3 Radiated Im m unity • EN 6 1000-4-3 , level 3 Perf Criteria A EFT/Burst • EN 6 1000-4-4, level 3 Perf Criteria A Surge • EN 6 1000-4-5, installation class 3 Perf Criteria A C onducted Im m unity • EN 6 1000-4-6 , level 3 Perf Criteria A, M IL-STD 46 1 CS114 D ips & Interruptions • EN 6 1000-4-11 , 3 0% 10 m s, 6 0% 100 m s, 100% 5000 m s, Perf Criteria A, B , B Safety Approvals • IEC6 0950-1 CB report, U L6 0950-1, TU V EN 6 0950-1 Equipm ent Protection • Class I C lass

31 Jan 17

Voltage Adjust. Pin 2 Pin 10 Pin 9 Pin 1 Signals Connector Exploded View Input Connector

3 Way AMP/Tyco

8.43 (21 4.00) 0.30 (7.72) 4.02 (102.00) Output Terminals (M4) Torque 8 in-lb (0.9 Nm) max Torque 13.2 in-lb (1.5 Nm) max 1.69 (43.00) 7.84 (199.00) M4 fixings in 6 positions Max. screw penetration to be 0.16 (4.0) from bottom face of baseplate 4.21 (107.00) 0.59 (15.00) 0.177 Ø (4.50) thru in 4 positions 3.48 (88.4) 0.27 (6.80) 8.23 (209.00) 0.20 (5.00) 1.18 (30.00) 2.83 (72.00) Pin 1 Pin 2 Pin 3 Input Connector CCH400/600 Models and Ratings Mechanical Details Thermal Considerations Notes 1. All dim ensions in inches (m m ). 2. T olerance .xx = ±0.02 (0.50); 3 . W eight 3 .3 lbs (1.5 kg) 4. Connector kit available, order part no. ‘CCH CO N KIT’ 5. Inhibit, overtem perature and pow er fail are referenced to the O V pow er term inal. Signal C onnector Pin Function

1 Current Share

2 Inhibit

3 O vertem p. W arning

4 Pow er Fail

Connector: 10 W AY 2m m pitch p/n M O LEX 8 78 3 3 -103 1 M ating half: p/n M O LEX 51110-1056 Contact: p/n M O LEX 503 94-8 100 Input C onnector Pin Function

1 Earth

2 N eutral

3 Line

Connector: 3 w ay AM P/T yco type M ATE-N -LO K 1-3 50943 -0 M ates w ith M ATE-N -LO K 3 5076 6 -1 O utput Pow er O utput Voltage V1 O utput C urrent V1 Standby Supply V2 M odel N um ber 411 W 12.0 VD C 3 4.0 A 5.0 V/0.5 A CCH 400PS12 411 W 24.0 VD C 17 .0 A 5.0 V/0.5 A CCH 400PS24 409 W 28 .0 VD C 14.5 A 5.0 V/0.5 A CCH 400PS28 411 W 48 .0 VD C 8 .5 A 5.0 V/0.5 A CCH 400PS48 6 03 W 12.0 VD C 50.0 A 5.0 V/0.5 A CCH 6 00PS12 6 03 W 24.0 VD C 25.0 A 5.0 V/0.5 A CCH 6 00PS24 6 05 W 28 .0 VD C 21.5 A 5.0 V/0.5 A CCH 6 00PS28 6 03 W 48 .0 VD C 12.5 A 5.0 V/0.5 A CCH 6 00PS48 The baseplate m ust be m aintainedat or below 8 5 °C and therefore a suitable heatsink m ust be selected to rem ove the heat from the pow er supply. D etails of the heatsink calculations and other considerations can be found in the longform datasheet. -40 -20 0 +85 100 Baseplate Temperature (º C) Some specification parameters may not be met Output Load (%) See note 5.