- 250 W Convection Cooled
- 300 W Peak Rating 500 ms
- Very High Efficiency up to 95%
- 1U Form Factor
- 5 V Standby Rail
- 80 V - 275 VAC Input Operation
- IT & Medical (BF)Safety Approvals
- Remote On/Off & Power Fail Signal as Standard The CCB250 range of single output AC-DC 250 W nominal, 300 peak power supplies feature industry leading useable efficiency of 93% and absolute minimum efficiency of 90% with 90 VAC input and full load. This leap in efficiency has been achieved with full resonant ZCS topology and careful consideration to every aspect of power loss resulting in a convection cooled power supply packaged in a 6” (153mm) x 4” (102mm) x 1.5” (38mm) open frame design which can be easily installed into end applications due t o a significant reduction in the dissipated heat, associated with other power supplies in this power range. The six standard models cover the voltage range from 12V - 48V , have dual input fusing and are compliant with IEC60601-1 Medi cal (BF) and IEC60950-1 IT safety approvals. The CCB250 series also boasts low earth leakage current of typically 60 μA at 115V and 110 μA at 230V, class B conducted emissions, 5V standby rail, power fail signal and remote on / off.
xppower.com Input Characteristics Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage - Operating 80 115/230 275 VAC Derate output power <90 VAC. See fig 1. Power fail signal cannot be used <90 VAC. Input Frequency 47 50/60 63 Hz Power Factor >0.9 EN61000-3-2 class A compliant Input Current - No Load 0.13/0.17 A 115/230 VAC Input Current - Full Load 2.4/1.2 A 115/230 VAC Inrush Current 30 A 230 VAC, 25 °C Earth Leakage Current 60/110 250 μA 115/230 VAC/50 Hz (T yp.), 264 VAC/60 Hz (Max.) Input Protection T5.0A/250 V internal fuse in both line and neutral Output Characteristics Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage - V1 12 48 VDC See Models and Ratings table Initial Set Accuracy ±0.5 (V1) , ±5 (V2) % 50% load, 115/230 VAC Output Voltage Adjustment ±3 % V1 only via potentiometer. See mech. details (page 11). Minimum Load 0 A Start Up Delay 0.5 s 230 VAC full load (see fig.2) Hold Up Time 16 ms 90 VAC full load (see fig.3) Drift ±0.2 % After 20 min warm up Line Regulation ±0.5 % 90-264 VAC Load Regulation ±1 (V1) , ±5 (V2) % 0-100% load. T ransient Response - V1 4 % Recovery within 1% in less than 500 μs for a 50-75% and 75-50% load step Over/Undershoot - V1 5 % Ripple & Noise 1 (V1), 2 (V2) % pk-pk 20 MHz bandwidth (see fig.4 & 5) Overvoltage Protection 115 140 % Vnom DC. Output 1 only, recycle input to reset Overload Protection 125 165 % I nom Output 1 only, auto reset (see fig.6) Short Circuit Protection Continuous, trip & restart (hiccup mode) all outputs T emperature Coefficient 0.05 %/˚C Overtemperature Protection 110 °C Auto recovery - temperature of main transformer Patient Leakage Current 100 μA 264 VAC/60 Hz Models and Ratings - Convection-cooled Output Power Output Voltage V1 Output Current V1 Standby Supply Model Number P nom P peak (1) I nom I peak (1) 250 W 300 W 12.0 VDC 20.8 A 25 A 5.0 V/0.5 A CCB250PS12 250 W 300 W 15.0 VDC 16.7 A 20 A 5.0 V/0.5 A CCB250PS15 Notes: 1. Peak duration is 500 ms max, average power must not exceed 250 W.
xppower.com Start Up Delay From AC Turn On Figure. 2 V1 & V2 start up example from AC turn on (580 ms) Hold Up Time From Loss of AC Figure 3 V1 hold up example at 250 W load with 90 VAC input (42 ms) AC Figure. 1 200 150 100 250 80 85 275 Input Voltage (VAC) Peak Power Availability Output Power (W) 300 90 264 Input Voltage Derating
xppower.com Xxxxxxxxxx General Specifications Characteristic Minimum Typical Maximum Units Notes & Conditions Efficiency 93 % Full load (see fig.7 & 8 ) Isolation: Input to Output Input to Ground Output to Ground
4000 VAC
1500 VAC
Switching Frequency 30-500 / 25.6 / 51.2 kHz PFC / Boost / Main Converter. Power Density 6.9 W/in Mean Time Between Failure 369 kHrs MIL-HDBK-217F , Notice 2 +25 °C GB Weight 1.2 (550) lb (g) Efficiency Versus Load Power Loss 40% 50% 60% 70% 80% 90% 100% 10 20 30 40 50 60 70 80 90 100 Efficiency Load (%) 230VAC input 40% 50% 60% 70% 80% 90% 100% 10 20 30 40 50 60 70 80 90 100 Efficiency Load (%) 230Vac input Figure 7 CCB250PS12 Figure 8 CCB250PS24 Waste heat creates a big headache for system designers. The industry leading efficiency achieved by the CCB250 is 5-10% above e xisting topologies used in this power area. This can result in a 60% reduction in generated heat as shown below and enables the overall system to run much cooler and more reliably. Example 1 Example 2 Conventional Products CCB250 Efficiency 85 % 93 % Generated Heat 44.1 W 18.8 W % Losses 100 % 42 % Conventional Products CCB250 Efficiency 90 % 93 % Generated Heat 27 .8 W 18.8 W % Losses 100 % 67 %
Power Fail signal example at AC switch off Figure 11 V1 warning time example at Power Fail signal 230 VAC
250 W load (37 ms)
xppower.com Signals Power Fail Figure 9 Pin 7 CON 1 Power Fail Collector Power Fail Emitter Pin 8 CON 1 POWER SUPPLY Transistor On (<0.8 V): Input & Output Not OK Transistor Off (>4.5 V): Input & Output OK 2K2
5 V Standby Rtn
Pin 1, 3 & 5 CON 1 Pin 2, 4 & 6 CON 1
5 V Standby
Characteristic Notes & Conditions Signals Power Fail Uncomitted opto isolated transistor, normally off when AC is good (see fig.9 - 11) Provides ≥ 5 ms (typically 20-30ms) warning of loss of output from AC failure Remote On/Off (Inhibit/Enable) Uncommited isolated optocoupler diode, powered diode inhibits the supply (see fig.12-17) Standby Supply V2 Isolated 5 V/0.5 A supply, always present when AC supplied. Power Fail
xppower.com Signals Remote On/Off (Inhibit/Enable) Inhibit Hi Pin 10 CON 1 POWER SUPPLY Signal Connector Inhibit Lo Pin 9 CON 1 2, 4 & 6 CON 1 Logic GND Pin 1, 3 & 5 CON 1 5 mA 8 V Max Figure 12 Inhibit (Hi) Figure 13 Inhibit (Lo) Figure 14 Example of outputs switching off when Inhibit (Lo) configuration used & switch closed Inhibit
8 V Max
Pin 2, 4 & 6 CON 1 Logic GND Pin 1, 3 & 5 CON 1 5 mA CON 1 Figure 15 Example of outputs switching on when Inhibit (Lo) configuration used & switch open Inhibit
Characteristic Minimum Typical Maximum Units Notes & Conditions Operating T emperature -20 (-40) +70 °C Derate linearly from +50 °C at 2.5%/°C to 50% at 70 °C. See fig.18 & Thermal Considerations, p.11. (-40 °C consult sales) Warm up T emperature 20 Minutes Storage T emperature -40 +85 °C Cooling Convection cooled. See fig.18 & Thermal Considerations, p.11. Humidity 5 95 %RH Non-condensing Operating Altitude 3000 m Shock 3 x 30 g/11 ms shocks in both +ve & -ve directions along the 3 orthogonal axis, total 18 shocks. Vibration Single axis 10-500 Hz at 2 g x 10 sweeps xppower.com Xxxxxxxxxx Inhibit Hi Pin 10 CON 1 POWER SUPPLY Signal Connector Inhibit Lo Pin 9 CON 1 Pin 2, 4 & 6 CON 1 Logic GND Pins 1, 3 & 5 CON 1 5 mA Inhibit Hi Pin 10 CON 1 POWER SUPPLY Pins 1, 3 & 5, CON 1 Inhibit Lo Pin 9 CON 1 Pin 2, 4 & 6, CON 1 Logic GND 5 mA Signal Connector Figure 16 Enable (Hi) Figure 17 Enable (Lo) Remote On/Off (Inhibit/Enable) XxxxxxxxxxSignals Notes 1. At AC switch on the output (VI) may momentarily rise when the unit is disabled using the 5 V standby in conjunction with the Remote On/Off function.
xppower.com Electromagnetic Compatibility - Immunity Phenomenon Standard Test Level Criteria Notes & Conditions Low Voltage PSU EMC EN61204-3 High severity level as below Harmonic Current EN61000-3-2 Class A Radiated EN61000-4-3 3 A EFT EN61000-4-4 3 A Surges EN61000-4-5 Installation class 3 A Conducted EN61000-4-6 3 A Dips and Interruptions EN61000-4-11 Dip: 30% 10 ms A Dip: 60% 100 ms B Dip: 100% 5000 ms B EN60601-1-2 (EN61000-4-11) Dip: 30% 500 ms A Dip: 60% 100 ms A Requires load derating to approx 80% with 115 VAC input. Dip: 100% 10 ms A Int.: >95% 5000 ms B Figure 18 Derating Curve 200 150 100 250 -20 -10 0 50 Ambient Temperature (°C) Output Power (W) 300 10 40 60 70 Peak Power Availability Electromagnetic Compatibility - Emissions Phenomenon Standard Test Level Criteria Notes & Conditions Conducted EN55022 Class B See fig. 19 Radiated EN55022 Class A Voltage Fluctuations EN61000-3-3
xppower.com Safety Agency Approvals Figure 19 - Typical conducted noise plot Typical EMC Plot Safety Agency Safety Standard Category CB Report Certificate # US/17818/UL IEC60950-1:2005 Ed 2 Information T echnology UL UL File #E139109-A62-UL UL60950-1 (2007), CSA 22.2 No.60950-1-07 Ed 2 Information T echnology TUV TUV Certificate # B11 10 57396 113, EN60950-1:2010 Information T echnology CE LVD Safety Agency Safety Standard Category CB Report Certificate #US/18197/UL, IEC60601-1 Ed 3 Including Risk Management Medical UL UL File # E146893, ANSI/AAMI ES 60601-1:2005 & CSA C22.2 No. 60601-1:08 Medical TUV TUV Certificate # B11 12 57396 124, EN60601-1:2006 Medical Equipment Protection Class Safety Standard Notes & Conditions Class I & BF IEC60950-1:2005 Ed 2 & IEC60601-1 Ed 3 See safety agency conditions of acceptability for details Means of Protection Category Primary to Secondary 2 x MOPP (Means of Patient Protection) IEC60601-1 Ed 3Primary to Earth 1 x MOPP (Means of Patient Protection) Secondary to Earth 1 x MOPP (Means of Patient Protection)
xppower.com Xxxxxxxxxx Mechanical Details Output Connector CON 3 1 +V1
2 V 1 RTN
- All dimensions in inches (mm). Weight 1.2 lb (550 g) approx In put Connector CON 4 Pin 1 Line Pin 2 Neutral Pin 3 Earth Signals Connector CON 1 1 5 V Standby Return 2 5 V Standby 3 5 V Standby Return 4 5 V Standby 5 5 V Standby Return 6 5 V Standby
7 Power Fail (Collector)
8 Power Fail (Emitter)
9 Remote On / Off (Cathode)
10 Remote On / Off (Anode)
CON 4 mates with Molex housing 09-50-1051 and Molex series 5194 crimp terminals. CON 1 mates with JST housing PHDR-10VS with contact SPHD-001T -P0.5 0.24 (6.1) 1.98 (50.4) 2.60 (66.3) Output Voltage Adjustment CON 3 -VE +VE Output Terminals M4 Screws in 2 positions torque to 8 lbs-in (90 cNm) max *Signal Connector CON 1 10-way JST-BI0B-PHDSS Mating Half - p/n JST PHDR-10VS, Contact- 26-22 AWG p/n JST SPHD-001T-P0.5 Pin 10 Pin 2 Pin 9 Pin 1 38.1 (1.5) 5.73 (145.42)0.14 (3.5) 3.73 (94.6) 0.74 (19.0) ø 3.5 through 4 places 6.00 (152.4) C12 C21 Output connectors allow connections from either top or side Signal Connector* 101.6 (4.0) 0.14 (3.5) L N E CON 4 Mounting holes married with must be connected to safety earth.
xppower.com 23-Sep-13 Thermal Considerations In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table be low must not be exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of any di rect air flow). See Mechanical Details for component locations. Service Life Estimated Service Life vs Component Temperature Temperature Measurements (Ambient ≤ 50 ºC) Component Max Temperature ºC L2 120 ºC C12 105 ºC C21 105 ºC The estimated service life of the CCB250 Series is determined by the cooling arrangements and load conditions experienced in th e end application. Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a key capacitor within the product when installed in the end application. The graph below expresses the estimated lifetime for a given component temperature and assumes continuous operation at this tem perature. 5000 25000 45000 65000 85000 105000 125000 145000 165000 185000 105 95 85 75 65 C64 Temperature (°C) Lifetime (Hrs) Figure 20