CB4 ALTECH | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Altech Corp.® •35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com W T T T C W C D 1 D 2 W T T H H D 1 D 2 H W H W H Dimensions mm Note: All dimensions are shown in mm, to con vert to inches please divide by 25.4. HIGH TEMPERATURE CERAMIC EUROBLOCKS™ Suitable for use in high temperature applications up to 600°C (1 1 12°F). Applications include hot melt glue guns, furnaces, heaters, process equipment and machinery. Terminal blocks are offered with mounting holes for panel mounting or free floating applications.

  • Compact, space saving
  • Tubular screw clamp
  • Free float or panel mount
  • Temperature range: 600°C (1 1 12°F)
  • Standard color: white
  • Material Housing: ceramic Clamp: brass Screws: zinc plated steel Ceramic 22-10 AWG 20-10 AWG 300V 300V

40 A 30 A

Cat. No. Std. Pk. CB6/1 50 CB6/2H 50 CB6/3H 50 Insulation Material Approvals Wire Range Voltage Rating Current Rating No. of Poles 1 (free floating) 2 (free floating) 2 (with mounting holes) 3 (free floating) 3 (with mounting holes) Ceramic 20-6 AWG 18-6 AWG 300V 300V

76 A 65 A

Cat. No. Std. Pk. CB16/2H 50 CB16/3H 50 Ceramic 24-12 AWG 24-12 AWG 300V 300V

30 A 20 A

Cat. No. Std. Pk. CB4/1 50 CB4/2 50 CB4/2H 50 CB4/3 50 CB4/3H 50 CU S CU S CU S W T H C D1 D2 Fixing Stripping Screw Length CB4/1 1 POLE 23 1 1 18.5 * 6 CB4/2 2 POLE 23 18 18.5 * 6 CB4/2H 2 POLE 23 24 18.5 14.6 6 3.5 M3X16 6 CB4/3 3 POLE 25 25 18.5 * 6 CB4/3H 3 POLE 25.4 36 18.5 13 6 3.5 M3X16 6 CB6/1 1 POLE 25 12 19.5 * 6 CB6/2H 2 POLE 25.5 26 19.5 12.6 6 M3X16 6 CB6/3H 3 POLE 25.5 41 19.5 15 6 M3X16 6 CB16/2H 2 POLE 28 31 23.2 16.5 6 3.5 M3X20 8.5 CB16/3H 3 POLE 27 .5 48 23.2 17 6 3.5 M3X20 8.5

1 Pole 2 Pole 2 Pole with

3 Pole 3 Pole with

Altech Corp.® •35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com46 CMT4SCMT4 MINI FEED-THROUGH 15mm DIN Rail For wire-to-wire connecting in control, automation, instrumentation and power distribution applications. Altech “miniature” terminal blocks offer tremendous space advantage as demanded by certain wiring configurations. FUSE BLOCKS Certain electrical and control systems require protection by fuses. The terminal has a hinged carrier that has a specially designed space for a cartridge type glass fuse of size Ø5 x 20 or Ø5 x 25 mm. The fuse can be engaged or disengaged by the movement of the carrier. Altech fuse terminals are also available with light indication - CSFL 4U (L). A specially designed built-in circuit gives light indication in the event of fuse blow out. Fuses are sold separately by Altech, see page 34 for details. * Add required voltage to part number as a suffix, i.e. CSFL4U(L)/24 fo 24V DC 6 mm 29 x 46 mm 9 mm Polyamide 6.6 2 screw clamps, 2 solder points and 1 tapped hole for cross connection 22-12 AWG Upto 1.5 sq.mm 22-10 AWG

300 V 160 V 300 V

25 A 15 A 35 A

7 lb-in 0.5 Nm 7 lb-in Cat. No. Std. Pk. CMT4S 50 EPCMT4 50 PPCMT4 50 CA602 50 CA727/2 100 CA727/3 50 CA727/4 50 CA727/10 10 CA747/2 100 CA747/3 50 CA747/4 50 CA747/10 10 CA703/1 100 CA704/1 100 CA705/1 100 CA732/10 100 CA732/10-A 100 CA732/100 10 CA607/S/Q 100 CA714/2 100 CA714/3 100 CA714/4 50 CA714/10 25 MT2 100 Terminal Width Height x Length Stripping Length Insulation Material Type of Connection Type of Fuse Used Approvals Wire Range Voltage Rating Current Rating Torque Terminal Block End Plate Isolation Partition DIN Rail for ordering information refer to page 62 End Stop for ordering information refer to page 63 Internal Jumper Insulated Internal Jumper Current Bars Shorting Sleeve & Screw External Jumper Marking Tags (MT Type) (MT Type on Lever) 6 mm 29 x 27 mm 9 mm Polyamide 6.6 2 screw clamps & 1 tapped hole for cross connection 22-10 AWG 0.5-4 sq.mm 22-10 AWG

300 V 400 V 300 V

35 A 32 A 35 A

6 lb-in 0.5 Nm 7 lb-in Cat. No. Std. Pk. CMT4 100 EPCMT4 50 PPCMT4 50 CA602 100 CA727/2 100 CA727/3 50 CA727/4 50 CA727/10 10 CA747/2 100 CA747/3 50 CA747/4 50 CA747/10 10 CA703/1 100 CA704/1 100 CA705/1 100 CA732/10 100 CA732/10-A 100 CA732/100 10 CA607/S/Q 100 CA714/2 100 CA714/3 100 CA714/4 50 CA714/10 25 MT2 100 2 pole 3 pole 4 pole 10 pole 2 pole 3 pole 4 pole 10 pole 2 pole 3 pole 4 pole 10 pole CU S CU S 2 pole 3 pole 4 pole 10 pole 10 pole (breakable) 100 pole

28.5 x 27 mm 9 mm Polyamide 6.6 2 screw clamps 22-10 AWG 0.5-4 sq.mm 22-10 AWG 7 lb-in 0.5 Nm 7 lb-in Cat. No. Std. Pk. CGMT4 50 MT2 100 CMT4SU CSFL4U CSFL4U(L)* 6 mm 29 x 35.5 mm 9 mm Polyamide 6.6 2 uneven level solder points & 1 tapped hole for cross connection 22-14 AWG Upto 1.5 sq.mm 22-14 AWG

15 A 15 A 20 A

– – – Cat. No. Std. Pk. CMT4SU 100 EPCMT4 50 PPCMT4 50 CA602 50 CA727/2 100 CA727/3 50 CA727/4 50 CA727/10 10 CA747/2 100 CA747/3 50 CA747/4 50 CA747/10 10 CA703/1 10 CA704/1 10 CA705/1 10 CA732/10 10 CA732/10-A 100 CA732/100 10 CA607/S/Q 10 MT2 100 8 mm 43 x 58 mm 9.5 mm Polyamide 6.6 2 screw clamps Ø5x20, Ø5x25mm 22-10 AWG 0.5-4 sq.mm 22-10 AWG

600 V 600 V 600 V

6.3 A 6.3 A 8 A 7 lb-in 0.5 Nm 7 lb-in Cat. No. Std. Pk. CSFL4U 100 EPCSFL4U 50 PPCSFL4U 50 CA602 100 CA711/2 100 CA711/3 100 CA711/4 50 CA711/10 25 MT8 100 MT2 100 8 mm 43 x 58 mm 9.5 mm Polyamide 6.6 2 screw clamps Ø5x20, Ø5x25mm 22-10 AWG 0.5-4 sq.mm 22-10 AWG 6.3 A 6.3 A 8 A 7 lb-in 0.5 Nm 7 lb-in Cat. No. Std. Pk. CSFL4U(L)* 100 EPCSFL4U 50 PPCSFL4U 50 CA602 100 CA711/2 100 CA711/3 100 CA711/4 50 CA711/10 25 MT8 100 MT2 100 C US C US C US C US Altech Corp.® •35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

Altech Corp.® •35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com48 EP CMB4 CMB4 MINI FEED-THROUGH Panel Mount For use when space constraints require extremely compact solutions and internal jumping is required. Individual components can be used to build your own assemblies. Just snap the required number of terminal block components together and place a Mounting Section on each end. The CMB 4 accepts internal jumpers and standard marking tags.

  • Extremely compact and cost effective
  • High density
  • Screw-cage clamp
  • Internal jumping provision
  • Polyamide 6.6
  • Standard color: gray Terminal Width Height x Length Stripping Length Insulation Material Type of Connection Approvals Wire Range Voltage Rating Current Rating Torque Terminal Block Mounting Section Separator Plate Mounting Screw* Internal Jumper Insulated Internal Jumper Current Bars Shorting Sleeve & Screw External Jumper Marking Tags (MT Type) 2 pole 3 pole 4 pole 10 pole 2 pole 3 pole 4 pole 10 pole 2 pole 3 pole 4 pole 10 pole 10 pole (breakable) 100 pole 2 pole 3 pole 4 pole 10 pole 6 mm 28 x 27 mm 9 mm Polyamide 6.6 2screw clamps & 1 tapped hole for cross connection 22-10 AWG 0.5-4 sq.mm 22-10 AWG

7 lb-in 0.5 Nm 7 lb-in Cat. No. Std. Pk. CMB4 100 EPCMB4 50 SPCMB4 100 CA727/2 100 CA727/3 50 CA727/4 50 CA727/10 10 CA747/2 100 CA747/3 50 CA747/4 50 CA747/10 10 CA703/1 100 CA704/1 100 CA705/1 100 CA732/10 100 CA732/10-A 100 CA732/100 10 CA607/S/Q 100 CA714/2 100 CA714/3 100 CA714/4 50 CA714/10 25 MT2 100 Dimensions mm (in.) CMB4 Mounting Section EPCMB4 No. of Hole Cat No. Poles Width (a) Spacing (b) CMB4/2 2 26 (1.02) 19 (0.75) CMB4/3 3 32 (1.26) 25 (0.98) CMB4/4 4 38 (1.50) 31 (1.22) CMB4/5 5 44 (1.73) 37 (1.46) CMB4/6 6 50 (1.97) 43 (1.69) CMB4/7 7 56 (2.20) 49 (1.93) CMB4/8 8 62 (2.44) 55 (2.17) CMB4/9 9 68 (2.68) 61 (2.40) CMB4/10 10 74 (2.91) 67 (2.64) CMB4/11 11 80 (3.15) 73 (2.87) CMB4/12 12 86 (3.39) 79 (3.11) CMB4/13 13 92 (3.62) 85 (3.35) CMB4/14 14 98 (3.86) 91 (3.58) CMB4/15 15 104 (4.09) 97 (3.82) CMB4/16 16 110 (4.33) 103 (4.06) CMB4/17 17 116 (4.57) 109 (4.29) CMB4/18 18 122 (4.80) 115 (4.53) CMB4/19 19 128 (5.04) 121 (4.76) CMB4/20 20 134 (5.28) 127 (5.00) CMB4/21 21 140 (5.51) 133 (5.24) CMB4/22 22 146 (5.75) 139 (5.47) CMB4/23 23 152 (5.98) 145 (5.71) CMB4/24 24 158 (6.22) 151 (5.94) b a * Any length M3 screw may be used. CU S Preassembled blocks are also available for quick and easy installations. See Dimensions below.

A quick reliable solution for ground, neutral or low voltage distribution applications. The Busbar System consists of a busbar, busbar supports, and screw clamp terminals for terminating wires NEB 10 (10 x 3 mm) and NEB 6 (6 x 6 mm), tin plated copper busbars are available in one meter lengths. Both have a 140A current carrying capacity. NES plastic support with fixing screws for holding 10 x 3 & 6 x 6 busbar makes placing of busbar an easy task. Busbars up to 200 mm length should be supported at ends by two busbar supports. For busbars exceeding 200 mm length, it is recommended to provide intermediate busbar support. Easy to operate CENC clamp secures wire to the busbar. Terminal Width Height x Length Stripping Length Insulation Material Type of Connection Approvals Wire Range Current Rating* Torque Terminal Block Busbar (10 x 3 mm) Busbar (6 x 6 mm) Plastic Support with Fixing Screw End Clamp/Bus bar support for rail mounting Marking Tags (MT Type) 7 .5 mm 9.8 mm 14.5 mm 30 x 23.3 mm 36 x 23.3 mm 45 x 27 .3 mm 12 mm 16 mm 16 mm Polyamide 6.6 Polyamide 6.6 Polyamide 6.6 1 screw clamp connection 1 screw clamp connection 1 screw clamp connection 22-12 AWG 0.5-6 sq.mm 22-12 AWG 9-6 AWG 6-16 sq.mm 10-6 AWG 7-2 AWG 10-35 sq.mm 8-2 AWG

25 A 41 A 76 A 76 A 125 A 125 A

14 lb-in 0.8 Nm 14 lb-in 14 lb-in 2.0 Nm 17 .5 lb-in 25 lb-in 2.5 Nm 25 lb-in CENC4 50 CENC16 50 CENC35 50 NEB10 1 m NEB10 1 m NEB10 1 m NEB6 1 m NEB6 1 m NEB6 1 m NES 50 NES 50 NES 50 CA202 50 CA202 50 CA202 50 MT5 100 MT6 100 MT6 100 CU S CU S CU S * 140A current carrying capacity of busbar should be taken into account while connecting loads. Consult for other available colors. Green Cap Altech Corp.® •35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com