CURRENT*1 RIPPLE CB101 0 to +10kV 0 to 100 µA <0.1% CB101N 0 to -10kV 0 to 100 µA <0.1% 5809J PAGE 1 100V to 10kV at 1 Watt Proven Reliability WWW.XPPOWER.COM

FEATURES

APPLICATIONS

MINIATURE, REGULATED HIGH VOLTAGE DC TO DC CONVERTERS PRODUCT SELECTION TABLE

  • Regulated
  • Low Noise, Quasi-Sinewave Oscillator
  • Miniature Size
  • 0 to 100% Programmable Output
  • High Stability
  • Wide Input Voltage Range, 11.5 to 16V
  • Very Low EMI/RFI
  • High Reliability: MTBF >2.6 Million Hours per Bellcore TR-332
  • Plated Steel Case with Isolated Case Ground
  • Sealed to Withstand Immersion Cleaning Process
  • External Gain Adjust for Calibration
  • Built-in Programming Voltage Overvoltage Protection
  • Built-in 5V Reference Voltage
  • Built-in Thermal Shutdown
  • Voltage Monitor: 0 – 5V = 0 – 100% Vout
  • Current Monitor: 0 – 5V = 0 – 100% Iout
  • UL Certified Encapsulant, Meets 94V-0 Flammability
  • RoHS Compliant
  • Extended Operating Temperature - Consult Factory
  • Electrophoresis
  • Capacitor Charging
  • Field Generation
  • Spectrometry
  • Deflection Plates
  • Test Instrumentation
  • Image Intensifier PRODUCT DESCRIPTIONPRODUCT DESCRIPTION The CB Series is new line of miniature, well regulated high voltage power supplies providing clean and reliable high voltage in a shielded, PC-mount package. Offering precision 0 to 100% programmability and very low ripple and EMI/ RFI, these cost-effective power supplies are ideal for integration into compact, sensitive equipment. The CB Series features current and voltage monitoring, built-in protection against pro- gramming overvoltage, and thermal shutdown. These modules come in a positive or negative output voltage of 10kV. For voltages ranging from 100V to 8kV, see the C series. 100 02 04 06 08 01 00 Output Voltage (0 to 100%) Programming Voltage (0 to 100%) Programming Voltage vs. Output Voltage

OUTPUT VOLTAGE MODEL OUTPUT CURRENT*1 RIPPLE P-P FULL-LOAD*3 REGULATION FREQUENCY*3 LOAD

0 TO 100%*3

11.5 TO 16.0V*3 0 to +10kV CB101 0 to 100 µA <0.1% <0.1% <0.1% 100 - 150kHz 0 to -10kV CB101N 0 to 100 µA <0.1% <0.1% <0.1% 100 - 150kHz 5809J PAGE 2 WWW.XPPOWER.COM CB SERIES ELECTRICAL SPECIFICATIONS*2 CB101 (10,000V) OUTPUT VOLTAGE VS VOLTAGE MONITOR OUTPUT CURRENT VS CURRENT MONITOR 0.0 1.0 2.0 3.0 4.0 5.0 0.5 1.5 2.5 3.5 4.5 0 20 40 60 80 10010 30 50 70 90 Voltage Monitor (0 to 5V) Output Voltage (0 to 100%) Output Voltage vs. Voltage Monitor 0.0 1.0 2.0 3.0 4.0 5.0 0.5 1.5 2.5 3.5 4.5 0 20 40 60 80 10010 30 50 70 90 Current Monitor (0 to 5V) Output Current (0 to 100%) Output Current vs. Current Monitor

INPUT VOLTAGE +11.5 to +16 VDC INPUT CURRENT <100 mA, No Load <225 mA, Full Load INPUT CAPACITANCE 440 uF low ESR PROGRAMMING VOLTAGE 0 to +5VDC, <100uA PROGRAMMING VOLTAGE OVERVOLTAGE <5.25VDC REFERENCE VOLTAGE 5VDC, 2mA CURRENT MONITOR 0 to +5VDC (Load current 0 to 100%), Error <0.5%*6 VOLTAGE MONITOR 0 to +5VDC (Load voltage 0 to 100%), Error <0.5%*6 RESPONSE TIME <250msec (Full Load, full scale response) (10–90%) SETPOINT ACCURACY*7 Adjustable +/- 1% (using gain adjust) LINEARITY*7 <1 % (20% to 100% Vout) STABILITY <0.01%/hr/8hrs TEMPCO <50 ppm/°C*3 THERMAL SHOCK LIMIT 1°C /10 seconds OPERATING TEMPERATURE -10 to +60°C*5 (CASE) (For wider range consult factory) STORAGE TEMPERATURE -20 to +100°C THERMAL SHUTDOWN > 85°C (CASE) 5809J PAGE 3 WWW.XPPOWER.COM ELECTRICAL SPECIFICATIONS*2 CB101 (10,000V) The CB Series is new line of miniature, well-regulated high voltage power supplies. The modules are programed from 0 to 100% of rated output via a 0 to +5 volt DAC compatible high impedance programming input voltage. The CB Series features current and voltage monitoring, built-in protection against programming overvoltage, and thermal shutdown. Temperature drift is typically less than 50 PPM/°C. A built-in reference voltage source can be used in lieu of the program- ming voltage. The CB Series exhibits very low ripple, noise, and EMI/RFI by utilizing a quasi-sinewave oscillator, shielded transformer, excellent filtering techniques, and an isolated steel enclosure featuring a separate grounding pin. An ex- ternally accessible potentiometer provides adjustable gain trim, allowing for individual calibration of units. A proprietary encapsulation process and high performance formula are used to achieve excellent high voltage and thermal proper- ties. Positive and negative outputs are offered. DETAILED PRODUCT DESCRIPTION CB SERIES

100 90 80 70 60 50 40 30 25 24 22 20 18 16 14 12 10 8642 1 Output Power (0 to 100%) Output Voltage (100 to 0%) Output Voltage vs. Output Power Derating Curve 5809J PAGE 4 WWW.XPPOWER.COM POWER DERATING CURVE CB SERIES

3.250 (82.55) 3.00 (76.20) .10 (2.64)Ø #2/M2 CLEARANCE FOR MOUNTING

2 PLACES

1.25 (31.75) 3.50 (88.90) 0.35 (8.89) 0.13 (3.18) 0.60 (15.24) 0.20 (5.08) PC PINS Ø 0.040 (1.02)

8 PLACES

10.0 (254.0) MIN 0.25 (6.35) 0.30 (7.62) GAIN ADJUST HIGH VOLTAGE OUTPUT LEAD (#22 AWG 20KV SILICONE) 0.63 (15.88) BOTTOM VIEW 0.23 (5.84) 0.300 (7.62) 0.600 (15.24) 0.800 (20.32) 0.400 (10.16) 0.70 (17.78) 0.625 TOP VIEW 0.14(3.56) WARNING HIGH VOLTAGE PCB LAYOUT .400 (10.16) .26 (6.63) .400 (10.16) 3.250 (82.55) 0.70 (17.78) Ø0.187 (4.75) MIN FOR POT ACCESS 0.300 (7.62) 0.600 (15.24) 0.800 (20.32) Ø.104 (2.64) FOR MOUNTING 0.23 (5.84) RECOMMENDED HOLE & PAD SIZE: Ø 0.052 (1.32) & Ø 0.090 (2.29) PIN # FUNCTION 1 (+) INPUT

2 GND

3 CASE GND*4

4 PROGRAMING VOLTAGE

6 CURRENT MONITOR

7 VOLTAGE MONITOR

8 HV RTN

WEIGHT 3 oz (85 grams) VOLUME 2.25 IN3 (36.87 CM3) CASE MATERIAL ZINC PLATED STEEL SEALED TO WITHSTAND IMMERSION CLEANING PROCESSES DIMENSIONS ARE IN INCHES (METRIC EQUIVALENTS ARE IN PARENTHESIS) WWW.XPPOWER.COM MECHANICAL SPECIFICATIONS CB101 (10,000V) CB SERIES

11.5 – 16 VDC 5VDC REFERENCE CASE GND CURRENT MONITOR VOLTAGE MONITOR LOAD GND LEAD VR2 VOUT Operate with 5VDC Reference Voltage Variable output R1 can be replaced with a potentiometer VR2 =( 5) R1 + R2 VOUT =( 10000) R1 + R2 APPLICATION NOTES CB SERIES WWW.XPPOWER.COM

11.5 – 16 VDC PROGRAMMING INPUT 0 – 5 VDC INVERTER RECTIFIERF ILTER CONTROL CURRENT MONITOR VOLTAGE MONITOR 5VDC REFERENCE GND CASE GND HV OUTPUT 0 – 10KV HV RETURN THERMAL SHUTDOWN GAIN ADJUST HV TRANSFORMER BLOCK DIAGRAM CB SERIES Model Output Voltage (See table) PART NUMBER SELECTOR: Model Number: Polarity Designator (Blank or N) CB 101 N HOW TO ORDER * Notes: 1. At Maximum Rated Output Voltage. 2. Specifications after 1 hour warm-up, full load, at 25°C unless other wise indicated. 3. Typical Performance. 4. All grounds internally connected, except case. There should not be more than 50 volts potential between the case ground (pin 3) and the circuit ground (pins 2 and 8). Isolated case assists low noise design efforts. Case pin must be connected to ground for proper operation. 5. Proper thermal management techniques are required to maintain safe case temperature at maximum power output. 6. 20–100%. 7. SET POINT ACCURACY refers to the ability of the unit to accurately deliver the voltage intended by the applied programming. The resultant output voltage will be within +/-1% of that programmed. LINEARITY refers to how much the transfer function can deviate from a straight line in the absence of any set point error. GAIN ADJUSTMENT refers to the ability to alter the gain of the circuit to bring the resultant output voltage to the programmed setpoint. This is intended to allow compensation for set point accuracy error. XP-EMCO reserves the right to make changes on products and literature, including specifications, without notice. XP-EMCO standard product models are not recommended for “copy-exact” applications or any other application restricting product changes. “Copy-exact” options are available. Please contact an XP-EMCO sales representative for more details. WWW.XPPOWER.COM