C6000RU MPD | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Key Features: 60W Output Power 4:1 Input Voltage Range 1,500 VDC Isolation -40ºC to +85ºC Operation Adjustable Output Remote ON/OFF >888 kHour MTBF Industry Standard Pin-Out C6000RU Isolated, 60W Ultra-Wide 4:1Input DC/DC Con vert ers Series Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Input Parameter Conditions Min. Typ. Max. Units Under Voltage Shutdown 24 VDC Input 8.0 VDC48 VDC Input 15.0 Input Filter /H9266 (Pi) Filter Start Up Time 70 mSec Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±1.0 % Line Regulation For Vin Min to Max ±0.5 % Load Regulation, See Note 1 Iout = 25% to 100% ±0.5 % Ripple & Noise, See Note 2 75 mV P-P Transient Recovery Time, See Note 3 50% Load Step Change 300 µSec Transient Response Deviation ±5.0 % Output Over Voltage Protection See Model Selection Guide Temperature Coeffi cient ±0.02 %/°C Output Short Circuit Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 1,500 VDC Isolation Resistance 500 VDC 1,000 M/H9024 Isolation Capacitance 100 kHz, 1V 1,200 pF Switching Frequency 300 kHz Remote On/Off, See Note 4 Parameter Conditions Min. Typ. Max. Units Supply On Open or 3.5 to 12 VDC Supply Off Short or 0.0 to 0.7 VDC Standby Input Current 20 mA Control Common Referenced to Negative Input (pin 2) Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +85 °C Operating Temperature Range Case +105 °C Storage Temperature Range -55 +125 °C Cooling See Derating Curve Humidity RH, Non-condensing 95 % Physical Case Material Nickel Coated Copper with Non-Conductive Base Weight 3.63 Oz (103g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 888 kHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Lead Temperature 1.5 mm From Case For 10 Sec 260 °C Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
Mechanical Notes:
- All dimensions are typical in inch es (mm)
- Tolerance x.xx = ±0.01 (±0.25) Derating Curve (3.3VDC, 5 VDC & 12 VDC Models) Model Number Input Output Effi ciency (Typ %) Over Voltage Protection (VDC) Capacitive Load (µF Max) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Voltage (VDC) Current (A, Max) Current (A, MinNom. Range Full-Load No-Load C6001RU 24 9 - 36 2,437 70 3.3 14.00 0.00 83 3.9 47,000 7,500 C6002RU 24 9 - 36 3,086 80 5.0 12.00 0.00 85 6.2 36,000 7,500 C6003RU 24 9 - 36 2,976 100 12.0 5.00 0.00 88 15 4,700 7,500 C6004RU 24 9 - 36 2,941 90 15.0 4.00 0.00 89 18 2,200 7,500 C6011RU 48 18 - 75 1,188 10 3.3 14.00 0.00 85 3.9 47,000 5,000 C6012RU 48 18 - 75 1,506 10 5.0 12.00 0.00 87 6.2 36,000 5,000 C6013RU 48 18 - 75 1,488 10 12.0 5.00 0.00 88 15 4,700 5,000 C6014RU 48 18 - 75 1,453 10 15.0 4.00 0.00 90 18 2,200 5,000 Pin Function Pin Function 1+ V IN 5 +Sense 2- V IN 6+ V OUT
3 On/Off 7 -V OUT
Notes: 1. For 3.3 VDC output models, the maximum load regulation is ±0.8%. 2. When measuring output ripple, it is recommended that external 1.0 µF & 10 µF capacitors be placed in parallel from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. 3. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. 4. If the on/off pin is left open, the unit operates. If grounded, the unit will shut off. 5. Sense pins should be connected to the output load or to the corresponding output pin. 6. No load operation will not damage these units, but they may not meet all spec’s. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Mechanical Dimensions www.micropowerdirect.com MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com A simple external circuit may be used to adjust the converter output. To adjust the output DOWN, connect a 5%, 3W resistor between the plus output pin and the Vout trim pin. To adjust the output UP , connect a 5%, 3W resistor between the minus output pin and the Vout trim pin. For UP/Down trimming capability, con- nect a 10 kW potentiometer between the plus and minus outputs with the wiper arm connected to the Vout trim pin. The range for the external trim is about ±10%. External Trim For heatsink option, add suffi x “H” to model number (i.e. C6003RU-H) Derating Curve (15 VDC Models)