Features

Surface Mount Package Optional Test Equipment Reflow Process Compatible Optional Synthesizers AT-Cut and SC-Cut Crystal Options Digital Switching Low Profile Compact Package Previous Vectron Model Numbers OCO50, OCO1000, MC4004X4 Frequency range

6 MHz – 60 MHz

Frequency stabilities1 [AT Cut Crystal – Standard] Parameter Min Typ Max. Units Operating temp range Ordering Code vs. operating temperature range -50 +50 ppb -20 … +70°C D508 (Referenced to +25°C) -100 +100 ppb -20 … +70°C D107 -100 +100 ppb -40 … +85°C F107 Parameter Min Typ Max. Units Condition Initial tolerance vs. supply voltage change vs. load change vs. aging / day vs. aging / year -500 -10 -10 -5.0 -250 +500 +10 +10 +5.0 +250 ppb ppb ppb ppb ppb at time of shipment, nominal EFC VS ± 5% Load ± 5% after 30 days of operation after 30 days of operation Warm-up Time minutes to ± 100ppb of final frequency (1 hour reading) @ +25°C Frequency stabilities1 [SC Cut Crystal – Option] Parameter Min Typ Max. Units Operating temp range Ordering Code vs. operating temperature range -10 +10 ppb -20 … +70°C D108 (Referenced to +25°C) -20 +20 ppb -20 … +70°C D208 -20 +20 ppb -40 … +85°C F258 Parameter Min Typ Max. Units Condition Initial tolerance vs. supply voltage change vs. load change vs. aging / day vs aging / year -200 -2.0 -5.0 -1.0 -75 +200 +2.0 +5.0 +1.0 +75 ppb ppb ppb ppb ppb at time of shipment, nominal EFC VS ± 5% Load ± 5% after 30 days of operation after 30 days of operation Warm-up Time minutes to ± 10ppb of final frequency (1 hour reading) @ +25°C Supply voltage (Vs) Parameter Min Typ Max. Units Condition Ordering Code Supply voltage [Standard] 4.75 5.25 VDC SV050 Supply voltage [Option] 11.4 12.0 12.6 VDC SV120 Supply voltage [Option] 3.135 3.3 3.465 VDC SV033 Power consumption 3.0 Watts during warm-up 1.0 Watts steady state @ +25°C

Vectron International · www.vectron.com v.2005-11-21 · page 2 of 5 Vectron International Headquarters

267 Lowell Road

Hudson, New Hampshire 03051 +1-888-328-7661 tel +1-888-329-8328 fax Vectron International LLC.

100 Watts Street

Mount Holly Springs, PA 17065 USA +1-717-486-3411 tel +1-717-486-5920 fax Vectron international GmbH & Co. KG Landstrasse D-74924 Neckarbischofsheim Germany +49-07268-801-0 tel +49-07268-801-281 fax Vectron Asia Pacific Sales Office 1F-2F, No 8 Workshop, No 308 Fenju Road, WaiGaoQiao Free Trade Zone, Pudong, Shanghai, P.R. China 200131 +86 21 5048 0777 tel. +86 21 5048 1881 fax RF output Parameter Min Typ Max. Units Condition Ordering Code Signal [Standard] HCMOS RFH Load pF Signal Level (Vol) 0.5 VDC with Vs=12.0V or 5.0V and 15pF load 0.3 VDC with Vs=3.3V and 15pF load Signal Level (Voh) 4.5 VDC with Vs=12.0V or 5.0V and 15pF load 3.0 VDC with Vs=3.3V and 15pF load Duty cycle @ (Voh-Vol)/2 Frequency Tuning (EFC) Parameter Min Typ Max. Units Condition Tuning Range ±1.0 ±1.75 ±2.5 ppm with SC Cut Crystal ±3.0 ±5.0 ppm with AT Cut Crystal Linearity Tuning Slope Positive Control Voltage Range 0.0 2.0 4.0 VDC with Vs=5.0VDC 0.0 2.0 4.0 VDC with Vs=12VDC 0.0 1.4 2.8 VDC with Vs=3.3VDC Reference Voltage Output (Vref) Parameter Min Typ Max. Units Condition Reference Voltage 3.92 4.0 4.08 VDC with Vs=5.0VDC 4.9 5.0 5.1 VDC with Vs=12VDC 2.75 2.8 2.85 VDC with Vs=3.3VDC Additional parameters Parameter Min Typ Max. Units Condition Phase Noise -90 dBc/Hz 1 Hz with 10 MHz SC Cut -120 dBc/Hz 10 Hz -140 dBc/Hz 100 Hz -145 dBc/Hz 1 kHz -150 dBc/Hz 10 kHz Phase Noise -75 dBc/Hz 1 Hz with 10 MHz AT Cut -105 dBc/Hz 10 Hz -130 dBc/Hz 100 Hz -140 dBc/Hz 1 kHz -150 dBc/Hz 10 kHz Weight g Processing & Packing Handling & processing note Absolute Maximum Ratings Parameter Min Typ Max. Units Condition Supply voltage (Vs) 7.0 V with Vs=5.0VDC 15.0 V with Vs=12VDC 7.0 V with Vs=3.3VDC Output Load pF Operable temperature range -55 +85 Storage temperature range -55 +125

Vectron International · www.vectron.com v.2005-11-21 · page 3 of 5 Vectron International Headquarters Hudson, New Hampshire 03051 +1-888-328-7661 tel +1-888-329-8328 fax Vectron International LLC. Mount Holly Springs, PA 17065 USA +1-717-486-3411 tel +1-717-486-5920 fax Vectron international GmbH & Co. KG Landstrasse D-74924 Neckarbischofsheim Germany +49-07268-801-0 tel +49-07268-801-281 fax Vectron Asia Pacific Sales Office 1F-2F, No 8 Workshop, No 308 Fenju Road, WaiGaoQiao Free Trade Zone, Pudong, Shanghai, P.R. China 200131 +86 21 5048 0777 tel. +86 21 5048 1881 fax Enclosures Type A Type B Type C Package Codes: Code Height “H” Pin Length “L” Code Height “H” Pin Length “L” Code Height “H” Pin Length “L” 10.5 4.5 min. 12.7 NA 11.3 NA 15.0 NA Dimensions: mm Dimensions: Imm Dimensions: mm 5-pin version available, without Pin 5 & 6 Pin Connections Pin Connections Pin Connections

1 Supply Voltage Input (Vs)

Electronic Frequency Control Input (EFC)

2 RF Output

3 Ground (Case)

Supply Voltage Input (Vs)

4 Electronic Frequency Control Input (EFC)

5 N.C. or Reference Voltage Output

5 N/C*

N/C*

6 RF Output Enable (Option)

N.C. or RF Output Enable (Option) Version with 7 pins available see Type B

7 Reference Voltage Output

Ground (Case) * Pin 5 must be remain unconnected. *Pin 5 must be remain unconnected. *Pin 5 must be remain unconnected. Standard Shipping Method *bei W ≤ 24 mm nur untere Lochreihe ∗by W ≤ 24 mm only lower hole line Gurtoberseite Tape upper side Gurtunterseite Tape buttom side Abwickelrichtung Unwinding direction Lage im Gurt Position in tape Pin 1 A X P B K Production tolerance complying DIN IEC 286-3 Enclosure Type Tape width W [mm] Quantity per meter Quantity per reel Dimension P Type B and C 37.5 280

Vectron International · www.vectron.com v.2005-11-21 · page 4 of 5 Vectron International Headquarters Hudson, New Hampshire 03051 +1-888-328-7661 tel +1-888-329-8328 fax Vectron International LLC. Mount Holly Springs, PA 17065 USA +1-717-486-3411 tel +1-717-486-5920 fax Vectron international GmbH & Co. KG Landstrasse D-74924 Neckarbischofsheim Germany +49-07268-801-0 tel +49-07268-801-281 fax Vectron Asia Pacific Sales Office 1F-2F, No 8 Workshop, No 308 Fenju Road, WaiGaoQiao Free Trade Zone, Pudong, Shanghai, P.R. China 200131 +86 21 5048 0777 tel. +86 21 5048 1881 fax Recommended Reflow Profile Profile Feature Pb-Free Assembly/Sn-Pb Assembly Average ramp-up rate (TL to Tp) 3°C/second max. Preheat -Temperature Min Tsmin) -Temperature Min Tsmax) -Time (min to max) (ts) 150°c 200°c 60-180 seconds Tsmax to TL - Ramp-up Rate 3°C/second max. Time maintainted above - Temperature (TL) - Time (tL) 217°C 60-150 seconds Peak Temperature (Tp) max 260°C Time within 5°C of actual Peak Temperature (tp) 20-40 seconds Ramp-down Rate 6°C/second max. Time 25°C to Peak Temperature 8 minutes max. Note: All temperatures refer to topside of the package, measured on the package body surface. Critical Zone TL to Tp Ramp up Ramp dow n t 25°C to peak Tp Temperature TL Time Ts Ts ts preheat tp tL

Vectron International · www.vectron.com v.2005-11-21 · page 5 of 5 Vectron International Headquarters Hudson, New Hampshire 03051 +1-888-328-7661 tel +1-888-329-8328 fax Vectron International LLC. Mount Holly Springs, PA 17065 USA +1-717-486-3411 tel +1-717-486-5920 fax Vectron international GmbH & Co. KG Landstrasse D-74924 Neckarbischofsheim Germany +49-07268-801-0 tel +49-07268-801-281 fax Vectron Asia Pacific Sales Office 1F-2F, No 8 Workshop, No 308 Fenju Road, WaiGaoQiao Free Trade Zone, Pudong, Shanghai, P.R. China 200131 +86 21 5048 0777 tel. +86 21 5048 1881 fax How to Order this Product: Step 1 Use this worksheet to forward the following information to your factory representative: Model Stability Code Supply Voltage Code RF Output Code Package Code Frequency C4500 Example: C4500 D107 SV050 RFH 20MHz Step 2 The factory representative will then respond with a Corning Model Number in the following Configuration: Model Package Code Dash Dash Number C4500 [Customer Specified Package Code] [Factory Generated 4 digit number] Typical P/N = C4500A1-0001 Notes: 1 Contact factory for improved stabilities or additional product options. Not all options and codes are available at all frequencies. 2 Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control voltage, load, temperature (25°C) 3 Phase noise degrades with increasing output frequency. 4 Subject to technical modification. 5 Contact factory for availability.