C2560_07 VECTRON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Vectron International · www.vectron.com v.2007-03-21 · page 1 of 4 Vectron International Headquarters

267 Lowell Road

Hudson, New Hampshire 03051 +1-888-328-7661 tel +1-888-329-8328 fax Vectron International LLC.

100 Watts Street

Mount Holly Springs, PA 17065 USA +1-717-486-3411 tel +1-717-486-5920 fax Vectron international GmbH & Co. KG Landstrasse D-74924 Neckarbischofsheim Germany +49-07268-801-0 tel +49-07268-801-281 fax Vectron Asia Pacific Sales Office Unit 3119 31st Floor, Jin Mao Tower,

88 Century Boulevard, Shanghai,

P.R. China 200120 +86 21 28909740 tel. +86 21 28909240 fax Typical Applications Features SONET/SDH Stratum 3 Compliant Synthesizers Tight Stability Optimized for Semtech SONET / SDH Synchronization Sets Low Aging Previous Vectron Model Numbers MC1200; TC-210 Frequency Range 10 MHz – 200 MHz Frequency stabilities 1 [ Stratum 3 TCXO] Parameter Min Typ Max. Units Operating temp range Ordering Code vs. operating temperature range -0.8 +0.8 ppm -40 … +85°C F807 (Referenced to +25°C) -0.28 +0.28 ppm -30 … +85°C G287 -0.28 +0.28 ppm -20 … +70°C D287 -0.28 +0.28 ppm 0 … +50°C B287 Parameter Min Typ Max. Units Condition Initial tolerance (w/ fixed frequency) vs. supply voltage change vs. load change vs aging /15 Years overall tolerance - 1.5 - 0.1 - 0.1 - 2.5 -4.6 +1.5 +0.1 +0.1 +2.5 -4.6 ppm ppm ppm ppm ppm at time of shipment, No EFC V S ± 5% Load ± 10% *Stratum 3 per GR-1244-CORE: <±4.6 ppm for all causes and 15 years aging, Holdover: <±0.37 ppm over 24 hours (Codes: D287 & B287) Supply voltage (Vs) Parameter Min Typ Max. Units Condition Ordering Code Supply voltage [Standard] 3.135 3.3 3.465 VDC SV033 Supply voltage [Option] 4.75 5 5.25 VDC SV050 Current consumption 15 mA mA steady state @ +25°C & 3.3VDC steady state @ +25°C & 5.0VDC RF output Parameter Min Typ Max. Units Condition Ordering Code Signal [Standard] HCMOS RFH Load 13.5 15 16.5 pF Rise and Fall time 5 ns 10% - 90% Duty cycle 40 50 % @ (Voh-Vol)/2 Signal [Standard] sinewave RFS Load 50 Ohm Output power 0 3 6 dBm Harmonics -30 dBc Sub harmonics -30 dBc If applicable Frequency Tuning (EFC) Parameter Min Typ Max. Units Condition Ordering Code Tuning Range Fixed (No EFC) 0 Tuning Range ± 8.0 ±12.0 ± 20.0 ppm Standard Version 1 Linearity 20 % Tuning Slope Positive 0.3 1.65 3.0 VDC with Vs=3.3VDC Control Voltage Range (nominal Freq. control input impedance 10 kΩ

Vectron International · www.vectron.com v.2007-03-21 · page 2 of 4 Vectron International Headquarters Hudson, New Hampshire 03051 +1-888-328-7661 tel +1-888-329-8328 fax Vectron International LLC. Mount Holly Springs, PA 17065 USA +1-717-486-3411 tel +1-717-486-5920 fax Vectron international GmbH & Co. KG Landstrasse D-74924 Neckarbischofsheim Germany +49-07268-801-0 tel +49-07268-801-281 fax Vectron Asia Pacific Sales Office Unit 3119 31st Floor, Jin Mao Tower, P.R. China 200120 +86 21 28909740 tel. +86 21 28909240 fax Additional parameters Parameter Min Typ Max. Units Condition Phase Noise 3 -115 dBc/Hz 100 Hz Stratum 3 TCXO @ -130 dBc/Hz 1 kHz 12.8 MHz -140 dBc/Hz 10 kHz Allan Variance 1x 10 -9 Tau= 1 sec Weight 9 g Processing & Packing Handling & processing note Enclosures Type A Package Codes: Code Height “H” Pin Length “L” A1 6.8 NA Dimensions: inches Pin Connections

1 RF-Output

2 Vs (supply voltage)

3 GND

4 N.C./EFC

5 GND

Outline Drawing: Marking C2560Ax-xxxx Frequency * C AYYWW Absolute Maximum Ratings Parameter Min Typ Max. Units Condition Supply voltage (Vs) 6.0 V Control Voltage 0 6.0 V Maximum output load @ CMOS 40 pF Operable temperature range -40 +85 °C Storage temperature range -55 +125 °C 1.150 1.00 (.39 MAX) .268 .797 .400 .400 1.000 .250 2 3 A .079 .098 R.024 DETAIL A SCALE 4 : 1

Vectron International · www.vectron.com v.2007-03-21 · page 3 of 4 Vectron International Headquarters Hudson, New Hampshire 03051 +1-888-328-7661 tel +1-888-329-8328 fax Vectron International LLC. Mount Holly Springs, PA 17065 USA +1-717-486-3411 tel +1-717-486-5920 fax Vectron international GmbH & Co. KG Landstrasse D-74924 Neckarbischofsheim Germany +49-07268-801-0 tel +49-07268-801-281 fax Vectron Asia Pacific Sales Office Unit 3119 31st Floor, Jin Mao Tower, P.R. China 200120 +86 21 28909740 tel. +86 21 28909240 fax Standard Shipping Method *bei W ≤ 24 mm nur untere Lochreihe ∗by W≤ 24 mm only lower hole line Gurtoberseite Tape upper side Gurtunterseite Tape buttom side Abwickelrichtung Unwinding direction Lage im Gurt Position in tape Pin 1A X P B K Production tolerance complying DIN IEC 286-3 Enclosure Type Tape width W [mm] Quantity per meter Quantity per reel Dimension P Recommended Reflow Profile 25º C 40 - 90 SEC WARM-UP 90 - 120 SEC DWELL 110º C 130º C 183º C 225 - 240º C 55 - 110 SEC RAMP 110 - 215 SEC COOL-DOWN 30 - 60 SEC REFLOW SMD oscillators must be on the top side of the PCB during the reflow process.

Vectron International · www.vectron.com v.2007-03-21 · page 4 of 4 Vectron International Headquarters Hudson, New Hampshire 03051 +1-888-328-7661 tel +1-888-329-8328 fax Vectron International LLC. Mount Holly Springs, PA 17065 USA +1-717-486-3411 tel +1-717-486-5920 fax Vectron international GmbH & Co. KG Landstrasse D-74924 Neckarbischofsheim Germany +49-07268-801-0 tel +49-07268-801-281 fax Vectron Asia Pacific Sales Office Unit 3119 31st Floor, Jin Mao Tower, P.R. China 200120 +86 21 28909740 tel. +86 21 28909240 fax How to Order this Product: Step 1 Use this worksheet to forward the following information to your factory representative: Model Stability Code Supply Voltage Code RF Output Code EFC Code Package Code Frequency C2560 Example: C2560 D206 SV033 RFH 1 A1 12.800 MHz Step 2 The factory representative will then respond with a Vectron Model Number in the following Configuration: Model Package Code Dash Dash Number C2560 [Customer Specified Package Code] - [Factory Generated 4 digit number] Typical P/N = C2560A1-0001 Notes: 1 Contact factory for improved stabilities or additional product options. Not all options and codes are available at all frequencies. 2 Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control voltage, load, temperature (25°C) 3 Phase noise degrades with increasing output frequency. 4 Subject to technical modification. 5 Contact factory for availability.