C1300_09 VECTRON | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Vectron International · www.vectron.com v.2009-09-15-05 · page 1 of 4 SEM Vectron International Headquarters
267 Lowell Road
Hudson, New Hampshire 03051 +1-888-328-7661 tel +1-888-329-8328 fax Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065 USA +1-717-486-3411 tel +1-717-486-5920 fax Vectron international GmbH & Co. KG Landstrasse D-74924 Neckarbischofsheim Germany +49-07268-801-0 tel +49-07268-801-281 fax Vectron Asia Pacific Sales Office Unit 3119 31st Floor, Jin Mao Tower, 88 Century Boulevard, Shanghai, P.R. China 200120 +86 21 28909740 tel. +86 21 28909240 fax Frequency Range 1 to 800 MHz (ACMOS and TTL outputs available up to 125 MHz. LVPECL and LVDS output frequencies above 220 MHz are achieved through the use of a PLL multiplier.) Frequency Stabilities 1 Parameter Min Typ Max Units Condition Ordering Code 5 Operating temperature range -100 +100 ppm 0 … +70° C C104 (referenced to +25° C) -50 +50 ppm 0 … +70° C C505 -25 +25 ppm 0 … +70° C C255 -15 +15 ppm 0 … +70° C C155 -100 +100 ppm -40 … +85° C F104 -50 +50 ppm -40 … +85° C F505 -25 +25 ppm -40 … +85° C F255 -100 +100 ppm -55 … +125° C M104 -50 +50 ppm -55 … +125° C M505 Initial accuracy (do not use with -15 +15 ppm @ 2 5° C T155 overall tolerance code below) -25 +25 ppm @ 25° C T255 -50 +50 ppm @ 25° C T505 -100 +100 ppm @ 25° C T104 Parameter Min Typ Max Units Condition Ordering Code 5 Overall tolerance (includes operating -100 +100 ppm 0 … +70° C TC104 temperature and initial accuracy) 7 -50 +50 ppm 0 … +70° C TC505 -25 +25 ppm 0 … +70° C TC255 -20 +20 ppm 0 … +70° C TC205 -100 +100 ppm -40 … +85° C TF104 -50 +50 ppm -40 … +85° C TF505 -25 +25 ppm -40 … +85° C TF255 -100 +100 ppm -55 … +125° C TM104 -65 +65 ppm -55 … +125° C TM605 Additional stability parameters: vs. Supply voltage change vs. Load change vs. Aging / 1st year vs. Aging / year (following years) ppm ppm ppm ppm V S ± 5% Load ± 5% Supply Voltage (Vs) Parameter Min Typ Max Units Condition Ordering Code 5 Supply voltage 4.75 5.0 5.25 VDC SV050 Current consumption 15 mA ACMOS or TTL 1.0 to 2 3.9 MHZ (+5 VDC) 20 mA ACMOS or TTL 24 to 49.9 MHz 40 mA ACMOS or TTL 50 to 125.00 MHz Supply voltage 3.135 3.3 3.465 VDC SV033 Supply voltage 2.375 2.5 2.625 VDC SV025 Current consumption 6 mA ACMOS 1.0 to 14.90 MHZ (+3.3 VDC or +2.5 VDC) 8 mA ACMOS 15.0 to 39.9 M Hz 12 mA ACMOS 40.0 to 59.9 MHz 16 mA ACMOS 60.0 to 84.9 MHz 40 mA ACMOS 85.0 to 125.0 MHz 75 mA LVPECL or LVDS No load <200 MHz Typical Applications Features Military Systems 9X14 J Leaded Surface Mount Package Avionics and Instrumentation Reflow Process Compati ble Test Equipment ACMOS, TTL, LVPECL and LVDS Medical Equipment MIL-PRF-55310 Class B Screening (optional) Military Operating Temperature Range (optional)
Vectron International · www.vectron.com v.2009-09-15-05 · page 2 of 4 SEM Vectron International Headquarters Hudson, New Hampshire 03051 +1-888-328-7661 tel +1-888-329-8328 fax Vectron International LLC. Mount Holly Springs, PA 17065 USA +1-717-486-3411 tel +1-717-486-5920 fax Vectron international GmbH & Co. KG Landstrasse D-74924 Neckarbischofsheim Germany +49-07268-801-0 tel +49-07268-801-281 fax Vectron Asia Pacific Sales Office Unit 3119 31st Floor, Jin Mao Tower, 88 Century Boulevard, Shanghai, P.R. China 200120 +86 21 28909740 tel. +86 21 28909240 fax 100 mA LVPECL or LVDS No load >200 MHz RF Output Parameter Min Typ Max Units Condition Ordering Code 5 Signal ACMOS RFA Load 15 50 pF Signal Level (Vol) 0.5 VDC Vs= 5.0V and 15pF loa d 0.3 VDC Vs=3.3V and 15pF load 0.25 VDC Vs=2.5V and 15pF load Signal Level (Voh) 4.5 VDC Vs= 5.0V and 15pF loa d 3.0 VDC Vs=3.3V and 15pF load 2.25 VDC Vs=2.5V and 15pF load Rise and fall times for ACMOS (measured 10% to 90%) ns ns ns 1.0 to 23.9 MHz 24.0 to 79.9 MHz 80.0 to 125.0MHz Duty cycle 45 @ 50% Vs< 15 MHz @ 50% Vs >
15 MHz
Signal Level (Vol) 0.5 VDC Vs= 5.0V and 15pF load Signal Level (Voh) 4.5 VDC Vs= 5.0V and 15pF loa d Rise and fall times for TTL (measured 0.8V to 2.0V) ns ns 1.0 to 23.9 MHz 24 to 125 MHz Duty Cycle 45 @ 1.4V < 15 MHz @ 1.4V > Load 50 Ω Into Vcc-2V or Thevenin Equivalent Signal Level (Vol) Vs -1.62 VDC -40 … +85° C operating temp Signal Level (Voh) Vs- 1.025 VDC -40 … +85° C oper ating temp Rise and fall times (measured @ 20% to 80%) 1000 600 ps ps <100 MHz
100 MHz
Duty cycle LVPECL 45 55 % @ 50% Vdd Jitter (rms) 10 0.5 ps ps BW = 10Hz to 20 MHz BW = 12 kHz to 20 MHz Period Jitter (pk-pk) 40 ps 10,000 Samples - Risi ng edge Signal LVDS RFL Load 60 100 140 Ω Between outputs Signal Level (Vol)
1.2 VDC
Signal Level (Voh) 1.4 VDC Differential Voltage (Vod) 240 330 460 mVpeak Common Mode (Offset) Voltage (Vos) 1.125 1.2 1.375 V Start-up Time 10 mS Rise and fall times 600 1000 ps m easured @ 20% to 80% of Vod Duty cycle 45 55 % @ 50% of Vod Jitter (rms) 5 ps ps BW = 10Hz to 20 MHz BW = 12 kHz to 20 MHz Period Jitter (pk-pk) 40 ps 10,000 Samples - Risi ng edge Additional Parameters Screening Vectron Verification 9 V Screening Class B, MIL-PRF-55310, Rev.D B Output Enable 6 Logic "0" input = Outputs disabled (Tri-state) Logic "1" or floating input = Outputs enabled ) Standard for ACMOS, TTL and LVDS outputs Logic "0" or floating input = Outputs enabled Logic "1" input = Outputs disabled (Tri-state ) Standard for LVPECL output Weight < 2 grams Processing & Packing Handling & processing note
Vectron International · www.vectron.com v.2009-09-15-05 · page 3 of 4 SEM Vectron International Headquarters Hudson, New Hampshire 03051 +1-888-328-7661 tel +1-888-329-8328 fax Vectron International LLC. Mount Holly Springs, PA 17065 USA +1-717-486-3411 tel +1-717-486-5920 fax Vectron international GmbH & Co. KG Landstrasse D-74924 Neckarbischofsheim Germany +49-07268-801-0 tel +49-07268-801-281 fax Vectron Asia Pacific Sales Office Unit 3119 31st Floor, Jin Mao Tower, 88 Century Boulevard, Shanghai, P.R. China 200120 +86 21 28909740 tel. +86 21 28909240 fax Standard Environmentals Parameter Test Condition Vibration MIL-STD-202, Method 204, Condition G (30 G, 10Hz-2000Hz) Shock MIL-STD-202, Method 213, Condition I (100 G, 6ms, Sawtooth) Acceleration MIL-STD-883, Method 2001, Condition A (5000 G, Y1 Plane) Temperature Cycling MIL-STD-883, Method 1010, Condition B Thermal Shock MIL-STD-883, Method 107, Condition B Solderability MIL-STD-202, Method 208 Leak Test (Fine and Gross) MIL-STD-883, Method 1014, Condition A1 and C1 Absolute Maximum Ratings Parameter Min Typ Max Units Condition Supply voltage (Vs) 7.0 V Vs=5.0VDC 7.0 V Vs=3.3VDC Operable temperature range -55 +125 ° C Storage temperature range -62 +125 ° C Enclosures Type A – ACMOS or TTL Type B – LVPECL or LVDS Package Codes: Codes Height Stand-off Codes Height Stand-off A1 = 4 leads 0.188 max 0.043 max B1 = 6 leads 0.188 max 0.043 max E1 = Enable/Disable pin 1 (4.77) (1.09) E1 = Enable/Disable pin 1 (4.77) (1.09) X = N/C pin 1 E2 = Enable/Disable pin 2 X = N/C pin 1 and pin 2 T= Tinned J leads 8 T= Tinned J leads 8 X= No Tinning X = No Tinning Pin Connections Pin Connections 1 – Enable/Disable or N/C 3 – RF Output 1 – Enable/Disable or N/C 4 – RF Output 2 – Ground (case) 4 – Supply Voltage 2 – N/C 5 – Co mplementary Output 3 – Ground (Case) 6 – Supply Voltage
Vectron International · www.vectron.com v.2009-09-15-05 · page 4 of 4 SEM Vectron International Headquarters Hudson, New Hampshire 03051 +1-888-328-7661 tel +1-888-329-8328 fax Vectron International LLC. Mount Holly Springs, PA 17065 USA +1-717-486-3411 tel +1-717-486-5920 fax Vectron international GmbH & Co. KG Landstrasse D-74924 Neckarbischofsheim Germany +49-07268-801-0 tel +49-07268-801-281 fax Vectron Asia Pacific Sales Office Unit 3119 31st Floor, Jin Mao Tower, 88 Century Boulevard, Shanghai, P.R. China 200120 +86 21 28909740 tel. +86 21 28909240 fax How to Order this Product: 10 Step 1 Use this worksheet to forward the following information to your factory representative (example follows): Model Stability Code Initial Accuracy Code (if required) Supply Voltage Code RF Output Code Screening Code Package Code Enable/Disable Code Tinning Code C1300 C505 T505 SV033 RFA V A1 E1 T Step 2 The factory representative will then respond with a Vectron Part Number in the following configuration: Model Package Code Dash Dash Number C1300 [Customer Specified Package Code] - [Factory Generated 4 digit number] Typical P/N C1300A1-0001 Notes: 1 Contact factory for improved stabilities or additional product options. Not all options and codes are available at all RF outputs and frequencies. 2 Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control voltage, load, temperature (25° C). 3 Phase noise degrades with increasing output frequency. 4 Subject to technical modification. 5 Contact factory for availability. 6 Contact factory for other options. 7 Overall stabilities do not require an initial accuracy code. 8 Leads tinned IAW Vectron International standard procedure (GR-37409). 9 Vectron Verification IAW Vectron International standard process (HK-69314). 10 Please be sure to specify nominal frequency.