BSE-SA ETA-USA | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com BSE-SA Series DIMENSION DIAGRAM
150 WATT
Specifications<AC BSE**SA-U 150WATTS/ SINGLE Input Voltage Input Current Input Range Input Frequency Input Frequency Range Phase Inrush Current *1 Efficiency [%] (typical) *2 77 82 83 85 85 87 88 88 88 89 Model BSE3.3SA-U BSE05SA-U BSE06SA-U BSE09SA-U BSE12SA-U BSE15SA-U BSE24SA-U BSE30SA-U BSE36SA-U BSE48SA-U Input Characteristic AC115V 17A(maximum) at AC115V AC85-132V 50/60Hz 47-440Hz Single
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Specifications<AC/DC> BSE**SA-U 150WATTS/SINGLE Input Voltage Input Current Input Range Input Frequency Input Frequency Range Phase Inrush Current *1 Efficiency [%] (typical) *2 77 82 83 85 85 87 88 88 88 89 Output Characteristic Output Voltage [V] 3.3 5 6 9 12 15 24 30 36 48 Output Current [A] 30 30 25 17 14 11 7 5.5 4.6 3.5 Voltage Adjust Range 2.7-3.63 Ripple and Noise [mVp-p](maxim um ) *3 150 150 160 190 220 250 340 400 460 580 Regulation a.Statistic Line Regulation [m V](maximum ) 26.4 40 48 72 96 120 192 240 288 384 b.Statistic Load Regulation mV 29.7 45 54 81 108 135 216 270 324 432 c.Temperature Coefficient *4 0.025%/ ℃ d.DriftmV *5 31.5 40 45 60 75 90 135 165 195 255 e.Dynamic Load Regulation mV *6 99 150 180 270 360 450 720 900 1080 1440 f.Recovery Time *6 Rise up time H old up t ime Functions Remote Sense Remote On/Off Operating Temperature Operating Humidity Storage Temperature Storage Humidity Isolation Resistance Vibration Shock Cooling ? Leakage Current ? W eight (typical) ? MTBF [H] ? Switching FrequencykHz Model BSE3.3SA-U BSE05SA-U BSE06SA-U BSE09SA-U BSE12SA-U BSE15SA-U BSE24SA-U BSE30SA-U BSE36SA-U BSE48SA-U Input Characteristic AC115V AC85-132V 50/60Hz 47-440Hz Single 17A(maximum) at AC115V +/-10% of Rated Output Voltage(at no load within the input range) 0.03%/ ℃ 0.5mS(typical) 500mS(maximum) at 25 ℃ and rated input/output 15mS (minimum) at 25 ℃ and rated input/output Overcurrent Protection ≧103% of Rated Output Current[A] Current Limiting with automatic recovery Overvoltage Protection ≧114% of Rated Output Voltage[V] Output shutdown(to reset,leave 1minute after shut-off) not available not available Environmental Convection:-10 to +40 ℃/Forced air:-10 to +60 ℃ 30 to 85%RH(non-condensing) -20 to +85 ℃ 10 to 85%RH(non-condensing) W ithstanding Voltage Primary-Secondary AC1500V for 1minute Primary-Frame Ground AC1500V for 1minute Secondary-Frame Ground AC500V for 1minute Primary-Secondary-Frame Ground 50M Ω(minimum) by DC500V insulation tester 5-10Hz:10mm double amplitude,10-55Hz:19.6m/s 2,20minutes' period for 60minutes each along X,Y,Z axes(non-operating) 294m/s 2 Convection 1mA(maximum) at 25 ℃,rated input/output and rated input frequency ? Line Conducted Noise Built to meet FCC Part15-B Class B Built to meet VCCI Class B ? Safety UL: UL1950 C-UL: CSA C22.2 No.950 open board type:450g 550,000 130 Conditions: *1at cold start *5 for 7hour period after 1hour warm-up at 25 ℃ and rated input/output *6 when output current changed from 25% of rated output current to 75% rapidly at AC100V input *2 at DC130V input/rated output *3 measured by a bayonet probe at the end of a pair of 5cm long wires terminated with a 100uF electrolytic capacitor and 0.1uF film capacitor in parallel at a 0 to 100MHz bandwidth *4 Convection:at -10 to +40 ℃/Forced air:at -10 to +60 ℃