BSD-SA-U ETA-USA | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com
100 WATT
Specifications<AC/DC> BSD**SA-U 100WATTS/SINGLE Input Voltage Input Current Input Range Input Frequency Input Frequency Range Phase Inrush Current *1 Efficiency [%] (typical) *2 73 76 78 82 82 84 87 87 88 50/60Hz 47-440Hz Single 17A(maximum) at AC115V Input Characteristic AC115V 2.2A AC85-132V Model BSD3.3SA-U BSD05SA-U BSD06SA-U BSD09SA-U BSD12SA-U BSD15SA-U BSD24SA-U BSD36SA-U BSD48SA-U
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Specifications<AC/DC> BSD**SA-U 100WATTS/SINGLE Output Voltage [V] 3.3 5 6 9 12 15 24 36 48 Output Current [A] 20 20 17 11 9 7 5 3.3 2.5 Voltage Adjust Range 2.7-3.63 Ripple and Noise mVp-p *3 150 150 160 190 220 250 340 460 580 Regulation a.Statistic Line Regulation mV 40 40 48 72 96 120 192 288 384 b.Statistic Load Regulation mV 45 45 54 81 108 135 216 324 432 c.Temperature Coefficient *4 0.025%/C d.DriftmV *5 40 40 45 60 75 90 135 195 255 e.Dynamic Load Regulation mV *6 150 150 180 270 360 450 720 1080 1440 f.Recovery Time *6 Rise up time Hold up time Remote Sense Remote On/Off Operating Temperature Operating Humidity Storage Temperature Storage Humidity Vibration Shock Cooling Leakage Current Weight (typical) MTBF [H] Switching FrequencykHz 130 130 130 130 130 130 130 130 140 open board type:330g 580,000 Safety UL: UL1950 CUL:CSA C22.2 No.950 294m/s Convection 0.3mA(typical) at 25C,rated input/output and rated input frequency Line Conducted Noise Built to meet FCC Part15-B Class B Built to meet VCCI Class B Isolation Resistance Primary-Secondary-Frame Ground 50MOhm(minimum) by DC500V insulation tester 5-10Hz:10mm double amplitude,10-55Hz:19.6m/s2,20minutes' period for 60minutes each along X,Y,Z axes(non-operating) 20 to 85%RH(non-condensing) Withstanding Voltage Primary-Secondary AC1500V for 1minute Primary-Frame Ground AC1500V for 1minute Secondary-Frame Ground AC500V for 1minute Environmental Convection:-10 to +50C/Forced air:-10 to +60C 20 to 85%RH(non-condensing) -20 to +85C Overvoltage Protection = or >114% of Rated Output Voltage[V] Output shutdown(to reset,leave 1minute after shut-off) not available not available 500mS(typical) at 25C and rated input/output 15mS (minimum) at 25C and rated input/output Functions Overcurrent Protection = or >103% of Rated Output Current[A] Current Limiting with automatic recovery +/-10% of Rated Output Voltage(at no load within the input range) 0.03%/C 0.5mS(typical) Model BSD3.3SA-U BSD05SA-U BSD06SA-U BSD09SA-U BSD12SA-U BSD15SA-U BSD24SA-U BSD36SA-U BSD48SA-U Conditions: *1at cold start *2 at DC130V input/rated output *3 measured by a bayonet probe at the end of a pair of 5cm long wires terminated with a 100uF electrolytic capacitor and 0.1uF film capacitor in parallel at a 0 to 100MHz bandwidth *4 convection at -10 to +50℃/forced air at-10 to +60℃ *5 for 7hour period after 1hour warm-up at 25℃ and rated input/output *6 when output current changed from 25% of rated output current to 75% rapidly at AC100V input