BSB12SA ETA-USA | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Features
- Cost effective 2. High efficiency 3. Small size 4. Input: 85-132VAC 5. Mountable, 5 ways mounting Options Cover Wire harness 60 & 80 WATT AC-DC
ETA-USA Tel: 408-778-2793 Fax: 408-779-2753 e-mail: sales@eta-usa.com Specifications<AC/DC> BSB**SA-HAS 60/80WATTS/SINGLE Output Voltage [V] 12 24 Output Current [A] 5.0 3.3 Voltage Adjust Range Ripple an d Noise [mVp-p](max imum ) *3 170 300 Regulation a.Statistic Line Regulation mV 96 192 b.Statistic Load Regulation [mV](max imum ) 108 216 c.Tempera ture Coeffi cient *4 d.DriftmV *5 75 135 e.Dynamic Load Regulation mV *6 360 720 f.Recovery Time *6 40mS 40mS Rise up time Hold up time 5.5 3.5 14 28 Remo te Sense Remote On/Off Operating Temperature Operating Humidity Storage Temperature Storage Humidity Isolation Resistance VibrationShock Cooling Leakage Curren t Line Conducted Noise W eight (typical) MTBF [H] Switching FrequencykHz *7 90 100 *7 variable on input voltage and load conditions capacitor and 0.1uF film capacitor in parallel at a 0 to 100MHz bandwidth *4 at -10 to +50 ℃ *5 for 7hour period after 1hour warm-up at 25 ℃ and rated input/output *6 when output current changed from 25% of rated output current to 75% rapidly at AC100V input Conditions: *1at cold start *2 at DC130V input/rated output *3 measured by a bayonet probe at the end of a pair of 15cm long wires terminated with a 100uF electrolytic 600,000 Safet y Convection 0.5m A(max imum ) at 25C,rate d input /output an d rate d input frequency Built to meet V CCI Class B open board type: 180g Primar y-Secondar y-Frame Ground 50MOhm (minimum ) by DC500V insulation tester 5-10Hz:10mm double amplitude,10-55Hz:19.6m/s 2,20minutes' period for 60minutes each along X,Y,Z axes(non-operating) 294 m/s2 20 to 90%RH(non-condensing) Withstanding Voltage Primary-Secondary AC1 ,500V for 1minute Primary-Frame Ground AC1,500V for 1minute Secondary-Frame Ground AC500V for 1minute Environmen tal -10 to +50C 20 to 90%RH(non-condensing) -20 to +85C Overvoltage Protection [V] Output shutdown (to rese t,leave 30secon ds after s hut-off) not available not available 20mS(minimum ) at 25C and rate d input /output Func tions Overcurrent Protection [ A] Curren t Limiting w ith automa tic recovery +/- 10% of Rated Output Voltage(at no load within the input range) 0.03 %/C 200m S(maximum ) at 25 C and rated input /output Model BSB12SA BSB24HSA Output Characteristic