BFE-SX-U1 ETA-USA | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.e ta-usa.com Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com BFE-SX-U1 SERIES General Description “BF”-Series AC/DC Switching power supplies are board type power supplies matched with new designs, which is in accordance with harmonic current regulation, of ultra-small sizes, high efficiency and low cost. By adopting the synchronization regular method (output less than 6 V) for the first time for this class of devices, BF-Series is 40mm smaller in depth compared with equivalent products by other makers. At the same time low cost is realized to meet market needs. Application Features Industrial Input 1. Board Type 2. Ultra Small size 3. Universal input(AC 85V to 264V) 4. Harmonic current complies to IEC61000-3-2 5. Power factor BFE: 0.98/0.93 (AC 100/230V) 6. High efficiency 7. Low Cost 8. EMI: complies to FCC class B, or EN55022 class B, or VCCI class B 9. Safety: UL 60950, C-UL, EN 60950-1 Options Input Voltage: Input Voltage Range: Input Current: Frequency: Input Frequency Range: Phase: Inrush Current: *1 Leakage Current: AC100-240V AC85-264V 2.0-0.9 A 50/60Hz 47-63Hz Single 18A(typ.) at AC100V 41A(typ.) at AC230V 1mA(maximum)at 25 (rated input/output and rated input frequency) N/A Output Models Characteristic Unit BFE3.3SX BFE05SX BFE06SX BFE09SX BFE12SX BFE15SX BFE24SX BFE36SX BFE48SX Output Voltage Vdc 3.3 5 6 9 12 15 24 36 48 Output Current A 30 30 25 17 13 10.5 6.7 4.5 3.4 Voltage Adjust Range V ±10% of Rated Output Voltage Ripple&Noise(max)*2 mVpp 120/160 150 at 0 to 40°C /180 at -10 to 0°C Rise up time mS 500mS(maximum) at 25°C and rated input/output Hold up time mS 20mS(minimum) at 25°C and rated input/output Regulation a. Line Regulation mV 9.9 15 18 27 36 45 72 108 144 b. Load Regulation *3 mV 40 40 50 40 40 40 100 150 150 c. Temperature Coefficient *4 °C 0.03 %/°C d. Drift(maximum) *5 mV 13.2 20 24 36 48 60 96 144 192 e. Dynamic Load Regulation (typ.) *6 f. Recovery Time *6 mS 5 mS(typ.) Efficiency % 76/79 80/82 80/83 82/85 83/86 83/86 84/87 85/88 85/88 Power Factor 0.97/0.92 0.98(typical) at AC100V/0.92(typical) at AC230V AACC//DDCC SSWWIITTCCHHIINNGG PPOOWWEERR SSUUPPPPLLYY AACC IINNPPUUTT 8855~~226644 SSIINNGGLLEE CCHHAANNNNEELL OOUUTTPPUUTT
115500 WWAATTTTSS
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.e ta-usa.com Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com Conditions: *1 cold start *2 measured by a bayonet probe at the end of a pair of 5cm long wires terminated with a 100uF electrolytic capacitor and 0.1uF film capacitor in parallel at a 0 to 100MHz bandwidth *3 when output current changed from 0mA to rated output current *4 at -10 to +40°C *5 for 7hour period after 1hour warm-up at 25°C and rated input/output *6 when output current changed from 25% to 75% of rated output current rapidly at rated input Environmental Specification Operating Temperature -10 to +50 °C Operating Humidity less than 85%/RH(non-condensing) Storage Temperature -20 to +85 °C Storage Humidity less than 85%/RH(non-condensing) Withstanding Voltage Primary-Secondary AC3,000V for 1minute Primary-Frame Ground AC2,500V for 1minute Secondary-Frame Ground AC500V for 1minute Isolation Resistance Primary-Secondary-Frame Ground 50M Ω(minimum) by DC500V insulation tester Vibration 5-10Hz:10mm double amplitude,10-55Hz:19.6m/s2,20minutes' period for 60minutes each along X,Y,Z axes(non- operating) Shock 294m/s2 Cooling Convection Environmental Agencies Line Conducted Noise Built to meet FCC Part15-B Class B Built to meet VCCI Class B Built to meet CISPR Class B Built to meet EN55022 Class B Line Harmonic Distortion Built to meet IEC61000-3-2 Safety UL: UL60950-1 2 nd edition, IEC61000-3-2 C-UL: CSA60950 VDE EN60950-1 2006, IEC950, MTBF [H] 347000 377000 398000 Switching Frequency[kHz] 100(typ.) Function/Protection Over current Protection Current Limiting with automatic recovery Over voltage Protection output shutdown(to reset,leave 1minute after shut-off) Remote Sense not available Remote On/Off not available Power Fail Detection not available Series Operation available Parallel Operation not available Mechanical Dimension [mm] 75W × 180L × 38H Weight g 420g
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.e ta-usa.com Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com DDIIMMEENNSSIIOONN DDIIAAGGRRAAMM ((mmmm)) BBLLOOCCKK DDIIAAGGRRAAMM
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.e ta-usa.com Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com DERATING CURVE EFFICIENCY CURVE OCP CURVE