< For mounting cylindrical sensors with metal thread < Secure mounting of the sensor via a snap lock < Installation position defined by fixed stop < Adjustable via slot mounting Plastic mounting adapter, 8 mm Dimensions Dead stop 5.5 13.5 3.9 10.1 4.2 Technical Data General specifications Inside diameter 8 mm Ambient conditions Mechanical specifications Material black polycarbonate (PC) Construction type For sensors with 45° chamfer Release date: 2020-03--

23 Date of

Release date: 2020-03-23 Date of issue: 2020-06-29 Filename: 187004_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

Release date: 2020-03-23 Date of issue: 2020-06-29 Filename: 187004_eng.pdf BF 8-F Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Mounting flange Installation Position the mounting bracket on the desired place Mark the position of drilling holes in the mid section of the oblong holes Drill the mounting holes through the surface Screw on the mounting bracket slightly via the lateral oblong holes by using suitable M4 screws Stick the sensor through the mounting bracket and fix the sensor by the lid on the upper part of the bracket Adjust the bracket and make the final positioning Fix the mounting bracket finally with the screws Mounting