BAT62... Silicon Schottky Diode
- Low barrier diode for detectors up to GHz frequencies BAT62 BAT62-09SBAT62-02L BAT62-02W BAT62-03W BAT62-08SBAT62-07W BAT62-07L4 /G31 /G44 /G32 /G32 /G33 /G34 /G44 /G31 /G31 /G44 /G31 /G32 /G33 /G34 /G35 /G36 /G44 /G32 /G31 /G44 /G31 /G32 /G33 /G34 /G35 /G36 /G44 /G32 /G44 /G33 /G31 /G32 /G31 /G44 /G32 /G32 /G33 /G34 /G44 /G31 ESD: Electrostatic discharge sensitive device, observe handling precaution! Type Package Configuration LS(nH) Marking BAT62 BAT62-02L* BAT62-02W BAT62-03W BAT62-07L4 BAT62-07W BAT62-08S BAT62-09S* SOT143 TSLP-2-1 SCD80 SOD323 TSLP-4-4 SOT343 SOT363 SOT363 anti-parallel pair single, leadless single single parallel pair, leadless parallel pair parallel triple parallel pair, high isolation 0.4 0.6 1.8 0.4 1.8 1.6 1.6 62s L L 62s 62s 69s *Preliminary Data
BAT62... Maximum Ratings at TA = 25°C, unless otherwise specified Parameter Symbol Value Unit Diode reverse voltage VR 40 V Forward current IF 20 mA Total power dissipation BAT62, T S ≤ 85 °C BAT62-02L, -07L4, -03W, TS ≤ 108 °C BAT62-02W, TS ≤ 109 °C BAT62-07W, TS ≤ 103 °C BAT62-08S, -09S, TS ≤ 105 °C Ptot 100 100 100 100 100 mW Junction temperature Tj 150 °C Storage temperature Tstg -55 ... 150 Thermal Resistance Parameter Symbol Value Unit Junction - soldering point1) BAT62 BAT62-02L, -07L4, -03W BAT62-02W BAT62-07W BAT62-08S BAT62-09S RthJS ≤ 650 ≤ 420 ≤ 410 ≤ 470 ≤ 450 ≤ tbd K/W Electrical Characteristics at TA = 25°C, unless otherwise specified Parameter Symbol Values Unit min. typ. max. DC Characteristics Reverse current VR = 40 V IR - - 10 µA Forward voltage IF = 2 mA VF - 0.58 1 V Forward voltage matching2) IF = 2 mA ∆ VF - - 20 mV 1For calculation of RthJA please refer to Application Note Thermal Resistance 2∆VF is the difference between lowest and highest VF in a multiple diode component.
BAT62... Electrical Characteristics at TA = 25°C, unless otherwise specified Parameter Symbol Values Unit min. typ. max. AC Characteristics Diode capacitance V R = 0 V, f = 1 MHz CT - 0.35 0.6 pF Differential resistance VR = 0 V, f = 10 kHz R0 - 225 - kΩ
BAT62... Diode capacitance CT = ƒ (VR) f = 1MHz 00.0 EHD07062BAT 62 C VR T 10 20 30 V 40 0.2 0.4 0.6 0.8 pF 1.0 Reverse current IR = ƒ(VR) TA = Parameter 0 5 10 15 20 25 30 V 40 VR -1 10 0 10 1 10 2 10 3 10 uA IR 25°C 85°C 125°C Forward current IF = ƒ (VF) TA = Parameter VF 1 10 2 10 3 10 4 10 uA IF 25°C 85°C 125°C -40°C Forward current IF = ƒ (TS) BAT62 0 15 30 45 60 75 90 105 120 °C 150 TS mA IF
BAT62... Forward current IF = ƒ (TS) BAT62-02L, -07L4 0 15 30 45 60 75 90 105 120 °C 150 TS mA IF Forward current IF = ƒ (TS) BAT62-02W 0 15 30 45 60 75 90 105 120 °C 150 TS mA IF Forward current IF = ƒ (TS) BAT62-03W 0 15 30 45 60 75 90 105 120 °C 150 TS mA IF Forward current IF = ƒ (TS) BAT62-07W 0 15 30 45 60 75 90 105 120 °C 150 TS mA IF
BAT62... Forward current IF = ƒ (TS) BAT62-08S 0 15 30 45 60 75 90 105 120 °C 150 TS mA IF Permissible Puls Load RthJS = ƒ (tp) BAT62 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 1 10 2 10 3 10 K/WRthJS D=0.5 0.2 0.1 0.05 0.02 0.01 0.005 Permissible Pulse Load IFmax/ IFDC = ƒ (tp) BAT62 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 0 10 1 10 IFmax/IFDC D=0 0.005 0.01 0.02 0.05 0.1 0.2 0.5
BAT62... Permissible Puls Load RthJS = ƒ (tp) BAT62-02L, -07L4 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 1 10 2 10 3 10 K/WRthJS 0.5 0.2 0.1 0.05 0.02 0.01 0.005 D = 0 Permissible Pulse Load IFmax/ IFDC = ƒ (tp) BAT62-02L, -07L4 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 0 10 1 10 IFmax/IFDC D = 0 0.005 0.01 0.02 0.05 0.1 0.2 0.5 Permissible Pulse Load IFmax/ IFDC = ƒ (tp) BAT62-02W 10 -7 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 0 10 1 10 IFmax/IFDC D = 0 0.005 0.01 0.02 0.05 0.1 0.2 0.5 Permissible Puls Load RthJS = ƒ (tp) BAT62-02W 10 -7 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 1 10 2 10 3 10 K/WRthJS 0.5 0.2 0.1 0.05 0.02 0.01 0.005 D = 0
BAT62... Permissible Puls Load RthJS = ƒ (tp) BAT62-03W 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 1 10 2 10 3 10 K/WRthJS D=0.5 0.2 0.1 0.05 0.02 0.01 0.005 Permissible Pulse Load IFmax/ IFDC = ƒ (tp) BAT62-03W 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 0 10 1 10 IFmax/IFDC D=0 0.005 0.01 0.02 0.05 0.1 0.2 0.5 Permissible Puls Load RthJS = ƒ (tp) BAT62-07W 10 -7 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 1 10 2 10 3 10 K/WRthJS 0.5 0.2 0.1 0.05 0.02 0.01 0.005 D = 0 Permissible Pulse Load IFmax/ IFDC = ƒ (tp) BAT62-07W 10 -7 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 0 10 1 10 IFmax/IFDC D = 0 0.005 0.01 0.02 0.05 0.1 0.2 0.5
BAT62... Permissible Puls Load RthJS = ƒ (tp) BAT62-08S 10 -7 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 1 10 2 10 3 10 K/WRthJS 0.5 0.2 0.1 0.05 0.02 0.01 0.005 D = 0 Permissible Pulse Load IFmax/ IFDC = ƒ (tp) BAT62-08S 10 -7 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 0 10 1 10 IFmax/IFDC D = 0 0.005 0.01 0.02 0.05 0.1 0.2 0.5 Rectifier voltage Vout = ƒ (Vin) f = 900MHz RL = Parameter in kΩ 10 0 10 1 10 2 10 3 10 4 mV VI -3 10 -2 10 -1 10 0 10 1 10 2 10 3 10 4 10 mV VO 1000 500 200 100 Testcircuit D.U.T R IN R LC L 1nF50Ω V I V 0