BAT60B INFINEON | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
BAT60B... Silicon Schottky Diode
- High current rectifier Schottky diode with very low VF drop (typ. 0.24 V at IF = 10mA)
- For power supply applications
- For clamping and protection in low voltage applications
- For detection and step-up-conversion BAT60B /G31 /G32 ESD: Electrostatic discharge sensitive device, observe handling precaution! Type Package Configuration Marking BAT60B SOD323 single white/5 Maximum Ratings at TA = 25°C, unless otherwise specified Parameter Symbol Value Unit Diode reverse voltage1) VR 10 V Forward current IF 3 A Non-repetitive peak surge forward current (t ≤ 10ms) IFSM 5 Total power dissipation TS ≤ 28°C Ptot 1350 mW Junction temperature Tj 150 °C Operating temperature range Top -55 ... 125 Storage temperature Tstg -55 ... 150 Thermal Resistance Parameter Symbol Value Unit Junction - soldering point2) RthJS ≤ 90 K/W 1For TA > 25 °C the derating of VR has to be considered. Please refer to curve Permissible reverse voltage. 2For calculation of RthJA please refer to Application Note Thermal Resistance
BAT60B... Electrical Characteristics at TA = 25°C, unless otherwise specified Parameter Symbol Values Unit min. typ. max. DC Characteristics Reverse current1) VR = 5 V VR = 8 V VR = 5 V, TA = 80 °C VR = 8 V, TA = 80 °C IR 100 410 800 1500 µA Forward voltage1) IF = 10 mA IF = 100 mA IF = 500 mA IF = 1000 mA VF 0.2 0.26 0.32 0.36 0.24 0.32 0.4 0.48 0.3 0.38 0.5 0.6 V AC Characteristics Diode capacitance VR = 5 V, f = 1 MHz CT 12 25 30 pF 1Pulsed test: tp = 300 µs; D = 0.01
BAT60B... Reverse current IR = ƒ(VR) TA = Parameter 0 2 4 6 8 V 12 VR -10 10 -9 10 -8 10 -7 10 -6 10 -5 10 -4 10 -3 10 -2 10 A IR 25°C -40°C 85°C 125°C Forward current IF = ƒ (VF) TA = Parameter VF -5 10 -4 10 -3 10 -2 10 -1 10 0 10 A IF -40°C 25°C 85°C 125°CPermissible Reverse voltage VR = ƒ (TA) tp = Parameter; duty cycle < 0.01 Device mounted on PCB with Rth = 160 K/W 0 20 40 60 80 100 120 °C 150 TA V VR 300µs 100ms DC Forward current IF = ƒ (TS) 0 15 30 45 60 75 90 105 120 °C 150 TS 500 1000 1500 2000 2500 mA 3500 IF
BAT60B... Permissible Puls Load RthJS = ƒ (tp) 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp -1 10 0 10 1 10 2 10 K/WRthJS 0.5 0.2 0.1 0.05 0.02 0.01 0.005 D = 0 Permissible Pulse Load IFmax/ IFDC = ƒ (tp) 10 -6 10 -5 10 -4 10 -3 10 -2 10 0 s tp 0 10 1 10 2 10 IFmax/IFDC D = 0 0.005 0.01 0.02 0.05 0.1 0.2 0.5