Key Features:  30W Output Power  Compact 1 x 2 Inch Case  2:1 Input Voltage Range  1,500 VDC Isolation  Optional Remote ON/OFF  Overvoltage Protection  Industry Standard Pin-Out www.micropowerdirect.com MicroPower Direct

292 Page Street

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Input Parameter Conditions Min. Typ. Max. Units Input Filter /H9266 (Pi) Filter (Complies with EN55022 Class “A”) Reverse Polarity Input Current 2.0 A Short Circuit Input Power 4,500 mW Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±0.5 ±1.0 % Line Regulation Vin = Min to Max ±0.1 ±0.3 % Load Regulation, 2.5, 3.3, 5 Vout Iout = 0% to 100% ±0.5 ±1.0 % Load Regulation, 12, 15 Vout Iout = 10% to 100% ±0.5 ±1.0 % Ripple & Noise (20 MHz) (Note 1) 75 100 mV P - P Ripple & Noise (20 MHz) Over Line, Load & Temp. 120 mV P - P Ripple & Noise (20 MHz) 10 mV rms Output Power Protection 110 160 % Transient Recovery Time (Note 2) 25% Load Step Change 200 500 µSec Transient Response Deviation ±2.0 ±5.0 % Temperature Coeffi cient ±0.01 ±0.02 %/°C Output Short Circuit Continuous General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 1,500 VDC Isolation Test Voltage Flash Tested For 1 Sec 1,650 VDC Isolation Resistance 500 VDC 1,000 M/H9024 Isolation Capacitance 100 kHz, 1V 1,200 1,500 pF Switching Frequency 280 350 400 kHz Remote On/Off (Note 3) Parameter Conditions Min. Typ. Max. Units Supply On 2.5 100.0 VDC Supply Off -1.0 1.0 VDC Standby Input Current 5m A Control Common Referenced to Negative Input (pin 2) Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +25 +50 °C Operating Temperature Range Case +105 °C Storage Temperature Range -50 +125 °C Cooling Free Air Convection Humidity RH, Non-condensing 95 % RFI Six-Side Shielded Metal Case Physical Case Material Metal with Non-Conductive Base (Anodized Black Aluminum) Weight 1.13 Oz (32g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F , 25°C, Gnd Benign 600 kHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 24 VDC Input -0.7 50.0 VDC48 VDC Input -0.7 100.0 Lead Temperature 1.5 mm From Case For 10 Sec 260.0 °C Internal Power Dissipation All Models 5,500 mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.

Input Refl ected Ripple Current (mA, Typ) Output Over Voltage Protection (VDC) Effi ciency (%, Typ) Capacitive Load (µF Max) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load Model Selection Guide Notes: 1. When measuring output ripple, it is recommended that an external 1.0 µF ceramic capacitor be placed from the +Vout pin to the -Vout pin. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. The maximum control current at the on/off pin (pin 3) during a logic high is 5 µA. The maximum control current to the on/off pin at logic low is -100 µA. If the on/off pin is left open, the unit operates. If it is grounded, the unit will shut off. 4. Operation at no-load will not damage these units. However, they may not meet all specifi ca- tions. 5. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor (such as a low ESR 10.0 µF) on the input to insure start-up. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. For continuous UP/Down trimming capability, connect a 10 kW poten- tiometer between the plus and minus outputs with the wiper arm con- nected to the V OUT trim pin. The trim pin may be left fl oating if it is not used. An external resistor may also be used to adjust the converter output. To adjust the output UP , connect a 5%, 3W resistor between the minus output pin and the Vout trim pin. The output voltage is increased per the equation: RUP = (33 x VOUT) - (30 x VADJ) VADJ - VOUT To adjust the output DOWN, connect a 5%, 3W resistor between the plus output pin and the V OUT trim pin. The output voltage is decreased per the equation: RDwn = (36.667 x VADJ) - (33 x VOUT) VOUT - VADJ External Trim Where: VOUT = Nominal Output Voltage VADJ = Adjusted Output Volatage Units = VDC / k Mechanical Dimensions Heatsink Notes:

  • Use of the heatsink will extend the units operating temperature range by approximately 10°C.
  • The heatsink is black anodized aluminum. MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072  TEL: (781) 344-8226  FAX: (781) 344-8481  E-Mail: sales@micropowerdirect.com Pin Function 1+ V i n 2- V i n

3 ON/OFF

6 Trim

Heatsink Dimensions (Optional) For heatsink option, add suffi x “H” to model number (i.e. B3003RU-H) www.micropowerdirect.com For Remote Control option, add suffi x “R” to model number (i.e. B3003RU-R) Mechanical Notes:

  • All dimensions are typical in inch es (mm)
  • Tolerance x.xx = ±0.01 (±0.25) Derating Curve