B1000RW MPD | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Key Features:

  • 10W Output Power
  • UL Approved (File E245422)
  • 2:1 Input Voltage Range
  • 1,500 VDC Isolation
  • Meets EN55022 Class “A”
  • Compact 1 x 2 Inch Case
  • Single & Dual Outputs
  • Industry Standard Pin-Out MicroPower Direct

232 Tosca Drive

Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com B1 000RW Compact 1 x 2 Inch 10WCompact 1 x 2 Inch 10W Wide Input RangeWide Input Range DC/DC Con vert ersDC/DC Con vert ers Series Input Parameter Conditions Min. Typ. Max. Units Input Start Voltage 12 VDC Input 8.0 8.5 9.0 VDC24 VDC Input 15.0 17.0 18.0 48 VDC Input 30.0 33.0 36.0 Input Filter π (Pi) Filter (Complies with EN55022 Class “A”) Reverse Polarity Input Current 2.0 A Short Circuit Input Power 3,500 4,500 mW Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±0.5 ±1.0 % Output Voltage Balance Dual Output , Balanced Loads ±0.5 ±1.0 % Line Regulation Vin = Min to Max ±0.1 ±0.3 % Load Regulation Iout = 10% to 100% ±0.1 ±0.5 % Ripple & Noise (20 MHz) (Note 1) 50 75 mV P - P Ripple & Noise (20 MHz) Over Line, Load & Temp. 100 mV P - P Ripple & Noise (20 MHz) 15 mV rms Output Power Protection 120 % Transient Recovery Time (Note 2) 25% Load Step Change 150 300 μSec Transient Response Deviation ±2.0 ±4.0 % Temperature Coeffi cient ±0.01 ±0.02 %/°C Output Short Circuit Continuous General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 1,500 VDC Isolation Test Voltage Flash Tested For 1 Sec 1,650 VDC Isolation Resistance 500 VDC 1,000 M Ω Isolation Capacitance 100 kHz, 1V 120 160 pF Switching Frequency 260 300 340 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +25 +71 °C Operating Temperature Range Case -40 +90 °C Storage Temperature Range -50 +125 °C Cooling Free Air Convection Humidity RH, Non-condensing 95 % RFI Six-Side Shielded Metal Case Conducted EMI EN55022 Class “A” Physical Case Material Metal with Non-Conductive Base (UL94-V0) Weight 1.06 Oz (30g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F, 25°C, Gnd Benign 700 kHours Safety Standards UL 1950, EN 60950, IEC 60950 Safety Approvals UL, cUL; File No. E245422 Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 12 VDC Input -0.7 25.0 VDC24 VDC Input -0.7 50.0 48 VDC Input -0.7 100.0 Lead Temperature 1.5 mm From Case For 10 Sec 260.0 °C Internal Power Dissipation All Models 5,000 mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.

Effi ciency (%, Typ) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Re fl ected Ripple Current (mA, Typ) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full- Load No- Load Model Selection Guide Mechanical Dimensions MicroPower Direct www.micropowerdirect.com 232 Tosca Drive Stoughton, MA 02072 ■ TEL: (781) 344-8226 ■ FAX: (781) 344-8481 ■ E-Mail: sales@micropowerdirect.com Mechanical Notes:

  • All dimensions are typical in inch es (mm)
  • Tolerance x.xx = ±0.01 (±0.25)
  • Leads are gold plated for improved solderability. Pin Single Dual 1 +Vin +Vin 2 -Vin -Vin 3 +Vout +Vout

4 No Pin Common

Notes: 1. When measuring output ripple, it is recommended that an external 0.47 μF ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Operation at no-load will not damage these units. However, they may not meet all speci- fi cations. 4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and fl oat the output common. 5. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR <1.0 Ω at 100 kHz) capacitor be mounted close to the converter. For 12V input units, a 15 μF is recommended; for 24V & 48V units a 4.7 μF. 6. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Single Output (μF Max) 470 Dual Output (μF Max) ±2,200 Capacitive Load Derating Curve