292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com RoHS Compliant Key Features: 10W Output Power 2:1 Input Voltage Range 1,500 VDC Isolation Effi ciency to 86% Compact 1 x 2 Inch Case Single & Dual Outputs Industry Standard Pin-Out Lowest Cost!! B1000ERW Low Cost 1 x 2 Inch 10W Wide Input Range DC/DC Con vert ers Series Input Parameter Conditions Min. Typ. Max. Units Input Voltage Range 12 VDC Input 9.0 12.0 18.0 VDC24 VDC Input 18.0 24.0 36.0 48 VDC Input 36.0 48.0 72.0 Input Filter π (Pi) Filter Short Circuit Input Power 1,500 mW Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±3.0 % Output Voltage Balance Dual Output , Balanced Loads ±5.0 % Line Regulation Vin = Min to Max ±0.1 ±0.2 % Positive Load Regulation Iout = 25% to 100% 0.2 0.5 % Negative Load Regulation Iout = 25% to 100% 3.0 5.0 % Ripple Bandwidth = 20 Hz to 300 kHz 30 50 mV P - P Noise Bandwidth = DC to 20 MHz 100 mV P - P Output Power Protection 110 % Transient Recovery Time (Note 1) 25% Load Step Change 200 µSec Transient Response Deviation ±2.0 % Temperature Coeffi cient ±0.01 ±0.02 %/°C Output Short Circuit Continuous General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 1,500 VDC Isolation Resistance 500 VDC 1,000 MΩ Isolation Capacitance 100 kHz, 1V 130 pF Switching Frequency 300 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +25 +71 °C Operating Temperature Range Case -40 +25 +90 °C Storage Temperature Range -40 +125 °C Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Material Non-Conductive Black Plastic (UL94-V0) Weight 1.06 Oz (30g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F, 25°C, Gnd Benign 1.0 MHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 12 VDC Input -0.7 25.0 VDC24 VDC Input -0.7 45.0 48 VDC Input -0.7 100.0 Lead Temperature 1.5 mm From Case for 10 Sec 300 °C Internal Power Dissipation All Models 5,000 mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. A BudgetBudget Saver!! Saver!!Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com Model Selection Guide Mechanical Dimensions Mechanical Notes: All dimensions are typical in inch es (mm) Tolerance x.xx = ±0.01 (±0.25) Pin Single Dual 1 +Vin +Vin 2 -Vin -Vin 3 +Vout +Vout
4 No Pin Common
(µF Max) 400 Dual Output (µF Max) ±200 Capacitive Load Derating CurveNotes: 1. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 2. Output load regulation is specifi ed for a load change of 25% to 100%. 3. When measuring output ripple, it is recommended that an external ceramic capacitor (approx approx 1 µF to 10 µF) be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. 4. These units should not be operated with a load under 10% of full load. Operation at no-load may cause damage to the unit. 5. These converters are specifi ed for operation without external com- ponents. However, in some applications the addition of input/ouput capacitors will enhance stability and reduce output ripple. Recom- mended capacitor values are: Vin Input Capacitor Output Capacitor
12 VDC 100 µF 100 µF per 1A of Iout
24 VDC 100 µF 100 µF per 1A of Iout
48 VDC 100 µF 100 µF per 1A of Iout
For applications requiring very low output noise levels, a simple LC fi lter should be effective. 6. Dual output units may be connected to provide a 10V, 24V or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and fl oat the output common. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Model Number Input Output Effi ciency (%, Typ) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load B1001ERW 12 9.0 - 18.0 1,111 25 5 2,000 200 75 3,000 B1002ERW 12 9.0 - 18.0 1,068 25 12 832 83 78 3,000 B1003ERW 12 9.0 - 18.0 1,041 25 15 660 66 80 3,000 B1004ERW 12 9.0 - 18.0 1,157 25 ±5 ±1,000 ±100 72 3,000 B1005ERW 12 9.0 - 18.0 1,082 25 ±12 ±416 ±41 77 3,000 B1006ERW 12 9.0 - 18.0 1,041 25 ±15 ±333 ±33 80 3,000 B1011ERW 24 18.0 - 36.0 555 8 5 2,000 200 75 1,500 B1012ERW 24 18.0 - 36.0 534 8 12 832 83 78 1,500 B1013ERW 24 18.0 - 36.0 520 8 15 660 66 80 1,500 B1014ERW 24 18.0 - 36.0 563 8 ±5 ±1,000 ±100 74 1,500 B1015ERW 24 18.0 - 36.0 508 8 ±12 ±416 ±41 82 1,500 B1016ERW 24 18.0 - 36.0 496 8 ±15 ±333 ±33 84 1,500 B1021ERW 48 36.0 - 75.0 257 5 5 2,000 200 81 750 B1022ERW 48 36.0 - 75.0 242 5 12 830 83 86 750 B1023ERW 48 36.0 - 75.0 242 5 15 670 66 86 750 B1024ERW 48 36.0 - 75.0 264 5 ±5 ±1,000 ±100 79 750 B1025ERW 48 36.0 - 75.0 245 5 ±12 ±416 ±41 85 750 B1026ERW 48 36.0 - 75.0 245 5 ±15 ±333 ±33 85 750