Signal conditioned pressure transducers 1/6February 2009 / 530 www.sensortechnics.com
FEATURES
- Absolute, gage or differential pressure
- Precision ASIC conditioning
- Temperature compensated GENERAL DESCRIPTION The amplified ASDX offers a high level (4.0 V span) output on a very cost- effective basis. This family is fully calibrated and temperature compensated using an on-board ASIC. These sensors are intended for use with non-corrosive, non-ionic working fluids such as air and dry gases. Devices are available to measure absolute, differential, and gage pressures from 1 to 100 psi. The absolute devices have an internal vacuum reference and an output voltage proportional to absolute pressure. Differential devices allow application of pressure to either side of the sensing diaphragm and can be used for gage or differential measurements. All ASDX devices are accurate to within ±2.0 %FSS. The devices are characterized for operation from a single 5 V supply. The sensor is designed and manufactured according to standards laid down in ISO 9001.
APPLICATIONS
- Medical instrumentation
- Barometry
- HVAC controls
- Pneumatic controls ELECTRICAL CONNECTION Note: Capacitor 220 nF required between +Vs and GND and 15 nF between Vout and GND. It is important to place the capacitors as close to the pins as possible! Pins 4, 5, 6, 7 and 8 are internal device connections and should not be connected for any reason! ASDX 15 nF 220 nF 5 6 7 8 4 +Vs Vout GND3 N/C N/C
Signal conditioned pressure transducers 2/6February 2009 / 530 www.sensortechnics.com PRESSURE RANGES SPECIFICATIONS (VS = 5.0 VDC , TA = 25°C) rebmuntraPe gnarerusserPe russerptsruB 1 ).pyt(ytivitisneS R42A510XDSA5 1ot0 )a(isp )a(isp 762.0 isp/V R42A030XDSA0 3ot00 63 31.0 R42A001XDSA0 01ot00 510 40.0 R44D/R42G100XDSA1 ot0 )d,g(isp )d,g(isp 00.4 R44D/R42G500XDSA5 ot00 20 8.0 R44D/R42G510XDSA5 1ot00 37 62.0 R44D/R42G030XDSA0 3ot00 63 31.0 R44D/R42G001XDSA0 01ot00 510 40.0 D44D100XDSA1 ±ot05 0 0.2 D44D500XDSA5 ±ot00 20 4.0 D44D510XDSA5 1±ot00 33 31.0 D44D030XDSA0 3±ot00 67 60.0 D44D001XDSA0 01±ot00 510 20.0 PRESSURE SENSOR CHARACTERISTICS Maximum ratings Supply voltage VS 4.75 V to 5.25 VDC max. 6.50 VDC Output current Sink 2 mA Source 2 mA Lead temperature (2 - 4 sec.) 250 °C Environmental specifications Temperature ranges Compensated 0 to +85 °C Operating -20 to +105 °C Storage -40 to +125 °C Vibration: 10 g at 20 - 2000 Hz Shock: 100 g for 11 ms Caution! The sensor is not reverse polarity protected. Incorrect applications of excitation voltage or ground to the wrong pin can cause electrical failure. Application of supply voltage above the maximum can cause electrical failure.
Signal conditioned pressure transducers 3/6February 2009 / 530 www.sensortechnics.com PERFORMANCE CHARACTERISTICS 0.5 to 4.5 V ratiometric output (VS = 5.0 VDC , TA = 25°C) scitsiretcarahC. niM. pyT. xaMs tinU tesffoerusserporeZ2 4.20 5.28 5.2 V )SSF(napselacslluF 2 00.4 tuptuOe russerpdeificeps.xamta2 4.40 5.48 5.4 erusserpdeificeps.nimta2 4.00 5.08 5.0 )C°58ot0(ycaruccalatoT 3 0.2±S SF% etarelpmaS0 01z H yaledesnopseR 4 37.21 1.41s m petsnoitazitnauQ 5 3V m noitpmusnoctnerruC 6A m scitsiretcarahC. niM. pyT. xaMs tinU tesffoerusserporeZ2 4.00 5.08 5.0 V)SSF(napselacslluF 2 00.4 tuptuoelacslluF2 4.40 5.48 5.4 )C°58ot0(ycaruccalatoT 3 0.2±S SF% etarelpmaS0 01z H yaledesnopseR 4 37.21 1.41s m petsnoitazitnauQ 5 3V m noitpmusnoctnerruC 6A m All ASDX...D44D
Signal conditioned pressure transducers 4/6February 2009 / 530 www.sensortechnics.com TOTAL ACCURACY (-20 to +105°C) Specification notes: 1. If maximum burst pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may fracture. 2. Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure. Span is ratiometric to the supply voltage. 3. Total accuracy is the combined error from offset and span calibration, linearity, pressure hysteresis, and temperature effects. Linearity is the measured deviation based on a straight line. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Calibration errors include the deviation of offset and full scale from nominal values. 4. Delay time between sampling and signal change at the output. 5. The smallest change in the output voltage, given any change in pressure. -20 0 20 40 60 85 105 Temperature (°C) Total accuracy (%FSS) -1.0 -2.0 -3.0 3.0 2.0 1.0
Signal conditioned pressure transducers 5/6February 2009 / 530 www.sensortechnics.com PHYSICAL DIMENSIONS D4 package G2 package A2 package third angle projection dimensions in mm (inches) 16.89 (0.665) 1.27 typ (0.050 typ) 13.97 (0.550) 16.64 ±0.64 (0.655 ±0.025) 8.89 (0.350) 7.87 typ (0.310 typ) 4.5 (0.177) 2.54 typ (0.100 typ) 8.26 typ (.325 typ) 1.78 (0.070) 3.63 (0.143) 3.38 (0.133) 8.13 (0.320) 0.51 typ (0.02 typ) Low pressure port High pressure port 2.29 (0.090) 4.5 (0.177) 16.64 ±0.64 (0.655 ±0.025) 16.89 (0.665)1.27 typ (0.050 typ) 13.97 (0.550) 8.89 (0.350) 8.0 typ (0.315 typ) 2.29 typ (0.090 typ) 8.46 (0.333) 2.54 typ (0.100 typ) 0.51 typ (0.02 typ) 2 ° typ 16.89 (0.665) 1.27 typ (0.050 typ) 13.97 (0.550) 3.15 (0.124) 4.9 (0.193) 16.64 ±0.64 (0.655 ± 0.025) 8.89 (0.350)5.08 (0.200) 2.29 typ (0.090 typ) 4.5 (0.177) 2.54 typ (0.100 typ) 0.51 typ (0.02 typ) 6.99 (0.275) 1.19 typ (0.047 typ) 2.79 typ (0.11 typ)
Signal conditioned pressure transducers 6/6February 2009 / 530 www.sensortechnics.com SenSym and Sensortechnics reserve the right to make changes to any products herein. SenSym and Sensortechnics do not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
ORDERING INFORMATION
egnarerusserPe tulosbAe gaGe gaG/laitnereffiD isp1ot0R 42G100XDSAR 44D100XDSA isp5ot0R 42G500XDSAR 44D500XDSA isp51ot0R 42A510XDSAR 42G510XDSAR 44D510XDSA isp03ot0R 42A030XDSAR 42G030XDSAR 44D030XDSA isp001ot0R 42A001XDSAR 42G001XDSAR 44D001XDSA isp1±ot0 D44D100XDSA isp5±ot0 D44D500XDSA isp51±ot0 D44D510XDSA isp03±ot0 D44D030XDSA isp001±ot0 D44D001XDSA ELECTRICAL CONNECTIONS ASDX...A24R Other pressure ranges or calibrations are available on request Note: Pins 4, 5, 6, 7 and 8 are internal device connections and should not be connected for any reason! Vs (pin 1) identifier Vs (pin 1) identifier N/C N/C N/C N/C N/C N/C N/C N/C +Vs Vout GND N/C +Vs Vout GND N/C Vs (pin 1) identifier N/C N/C N/C N/C +Vs Vout GND N/C