RX-P (ARXP1)

ORDERING INFORMATION

Standard packing: 50 pcs. in an inner package; 500 pcs. in an outer package

3 GHz

RX-P RELAYS (ARXP) Nominal coil voltage Part No. Single side stable type 1 coil latching type 2 coil latching type

3 V DC ARXP1003 ARXP1103 ARXP1203

4.5 V DC ARXP104H ARXP114H ARXP124H

6 V DC ARXP1006 ARXP1106 ARXP1206

9 V DC ARXP1009 ARXP1109 ARXP1209

12 V DC ARXP1012 ARXP1112 ARXP1212

24 V DC ARXP1024 ARXP1124 ARXP1224

Compliance with RoHS Directive

FEATURES

  1. 60 W contact carrying power realized
  • Three times the contact carrying power achieved compared to previous 20 W RX relay.
  • Nominal switching capacity (when switching) also improved to 40W. 2. Excellent high frequency characteristics
  • High frequency characteristics (to 2.5GHz, Impedance: 50Ω, Initial) 3. Small size 4. High sensitivity Nominal operating power: 200mW (Single side stable type and 1 coil latching type) TYPICAL APPLICATIONS 1. Base stations (mobile phones, terrestrial digital, etc.) Used for redundant circuit construction in transmitter section. 2. Other applications High-frequency amp switching in wireless devices, etc. If you wish to use in applications with low level loads or with high frequency switching, please consult us. Insertion loss (Max.) 0.2dB Isolation (Min.) 60dB (Return loss) (Min.) 1.2 or less (20.8dB) Contact carrying power Max. 60W (at 20°C 68°F, New RX-P relays Contact arrangement 1: 1 Form C Coil voltage, DC 03: 3 V 4H: 4.5 V 06: 6 V 09: 9 V 12: 12 V 24: 24 V (H=0.5) ARXP 1 Operating function 0: Single side stable type 1: 1 coil latching type 2: 2 coil latching type /a4dE?H/a6fM=LA,ALE?AI/a2e>/a6f/a6f/a6b 2=CA"& 9A@/a6eAI@=O/a2c /a4e/a6fLA/a6d>AH $/a2c & %/a3a# 2/a4d All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.

RX-P (ARXP1) RATING 1. Coil data 1) Single side stable type 2) 1 coil latching type 3) 2 coil latching type Nominal coil voltage Pick-up voltage (at 20 C 68 Drop-out voltage (at 20 C 68 Nominal operating current 10%] (at 20 C 68 Coil resistance 10%] (at 20 C 68 Nominal operating power Max. applied voltage (at 60 C 140

3 V DC

75%V or less of nominal voltage (Initial) 10%V or more of nominal voltage (Initial) 66.7 mA 45 Ω 200 mW 110%V or less of nominal voltage 4.5 V DC 44.4 mA 101 Ω 6 V DC 33.3 mA 180 Ω 9 V DC 22.2 mA 405 Ω 12 V DC 16.7 mA 720 Ω 24 V DC 8.3 mA 2,880 Ω Nominal coil voltage Set voltage (at 20 C 68 Reset voltage (at 20 C 68 Nominal operating current 10%] (at 20 C 68 Coil resistance 10%] (at 20 C 68 Nominal operating power Max. applied voltage (at 60 C 140 75%V or less of nominal voltage (Initial) 75%V or less of nominal voltage (Initial) 66.7 mA 45 Ω 200 mW 110%V or less of nominal voltage 4.5 V DC 44.4 mA 101 Ω 6 V DC 33.3 mA 180 Ω 9 V DC 22.2 mA 405 Ω 12 V DC 16.7 mA 720 Ω 24 V DC 8.3 mA 2,880 Ω Nominal coil voltage Set voltage (at 20 C 68 Reset voltage (at 20 C 68 Nominal operating current 10%] (at 20 C 68 Coil resistance 10%] (at 20 C 68 Nominal operating power Max. applied voltage (at 60 C 140 75%V or less of nominal voltage (Initial) 75%V or less of nominal voltage (Initial) 133.3 mA 22.5 Ω 400 mW 110%V or less of nominal voltage 4.5 V DC 88.9 mA 50.6 Ω 6 V DC 66.7 mA 90 Ω 9 V DC 44.4 mA 202.5 Ω 12 V DC 33.3 mA 360 Ω 24 V DC 16.7 mA 1,440 Ω /a4dE?H/a6fM=LA,ALE?AI/a2e>/a6f/a6f/a6b 2=CA"' 9A@/a6eAI@=O/a2c /a4e/a6fLA/a6d>AH $/a2c & %/a3a# 2/a4d All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.

RX-P (ARXP1) 2. Specifications Notes: *1 Release time will lengthen if a diode, etc., is connected in parallel to the coil. Be sure to verify operation under actual conditions. *2 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to [6] AMBIENT ENVIRONMENT in GENERAL APPLICATION GUIDELINES. REFERENCE DATA Item Specifications Contact Arrangement 1 Form C Contact material Fixed: Au plating Movable: Au clad Contact resistance (Initial) Max. 100 m Ω (By voltage drop 10 V AC 10mA) Rating Nominal switching capacity 40W (at 2.5GHz, Impedance: 50 Ω Contact carrying power Max. 60W (at 2.5GHz, Impedance: 50 Ω Max. switching voltage 30 V DC Max. switching current 0.5 A DC Nominal operating power Single side stable type 200mW 1 coil latching type 200mW 2 coil latching type 400mW High frequency characteristics, Impedance: 50 Ω (to 2.5GHz) (Initial) Insertion loss Max. 0.2dB Isolation Min. 60dB Contact carrying power Max. 60W (at 20 C 68 Electrical characteristics Insulation resistance (Initial) Min. 100M Ω (at 500V DC, Measurement at same location as “Breakdown voltage” section.) Breakdown voltage (Initial) Between open contacts 500 Vrms for 1min. (Detection current: 10mA) Between contact and coil 1,000 Vrms for 1min. (Detection current: 10mA) Between contact and earth terminal 500 Vrms for 1min. (Detection current: 10mA) Temperature rise (at 20 C 68 F) Max. 60 C 140 F (By resistive method, nominal voltage applied to the coil, contact carrying power: 20W at 2.5GHz, 50 Ω Operate time [Set time] (at 20 C 68 Single side stable type Max. 10 ms (Approx. 6 ms) (Nominal voltage applied to the coil, excluding contact bounce time) 1 coil latching type Max. 10 ms (Approx. 5 ms) (Nominal voltage applied to the coil, excluding contact bounce time)2 coil latching type Release time [Reset time] (at 20 C 68 Single side stable type* Max. 6 ms (Approx. 3 ms) (Nominal voltage applied to the coil, excluding contact bounce time) (without diode) 1 coil latching type Max. 10 ms (Approx. 5 ms) (Nominal voltage applied to the coil, excluding contact bounce time)2 coil latching type Mechanical characteristics Shock resistance Functional Min. 200 m/s (Half-wave pulse of sine wave: 11 ms, detection time: 10 µ Destructive Min. 1,000 m/s (Half-wave pulse of sine wave: 6 ms) Vibration resistance Functional 10 to 55 Hz at double amplitude of 3 mm (Detection time: 10 µ Destructive 10 to 55 Hz at double amplitude of 5 mm Expected life Mechanical life Min. 10 (at 180 cpm) Electrical life Min. 10 (40W, at 2.5GHz, Impedance: 50 Ω Conditions Conditions for operation, transport and storage* Ambient temperature: –40 to 70 C –40 F to 158 F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Unit weight Approx. 5 g .18 oz 1. High frequency characteristics Sample: ARXP1012; Measuring method: Measured with Agilent Technologies network analyzer (E8363B). *For details see No. 8 under “NOTES”.

  • V.S.W.R. characteristics • Insertion loss characteristics (without D.U.T. board’s loss)
  • Isolation characteristics 40MHz 3GHz1.5GHz 2.5GHz 1.5 2.0 1.0 1.1 1.2 1.3 1.4 1.6 1.7 1.8 1.9 COM-NC COM-NO V.S.W.R Frequency 0.5 0.4 0.3 0.2 0.1 40MHz 3GHz 1.5GHz 2.5GHz COM-NC COM-NO Frequency Insertion loss, dB 100 40MHz 3GHz 1.5GHz 2.5GHz COM-NC COM-NO Frequency Isolation, dB /a4dE?H/a6fM=LA,ALE?AI/a2e>/a6f/a6f/a6b 2=CA# 9A@/a6eAI@=O/a2c /a4e/a6fLA/a6d>AH $/a2c & %/a3a# 2/a4d All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.

RX-P (ARXP1) DIMENSIONS (mm inch) NOTES 2.54 .100 .035 dia. hole 0.9 dia. hole 2 coil latching only 0.90 .035 2.54 .100 7.62 .300 R 0.45 .018(2.74) (.108) (2.04) (.080) 7.62 .3002.63 .104 20.5 .807 2.54 .100 7-.016 to .018 dia. 7-0.40 to 0.45 dia. 2-.024×.012 2-0.6×0.3 Part No. Lot No. Solder to the PC board earth. 12.4 .488 9.2 .362 3.0 .1180.2 .008 External dimensions Tolerance: ±0.3 ±.012 PC board pattern (Bottom view) Tolerance: ±0.1 ±.004 Schematic (Bottom view) (Reset condition) (Reset condition) (Deenergized condition) 2 coil latching 1 coil latching Single side stable RESET SETCOM 6 1 8 9 10 11 12 13 14 RESET SETCOM -+ 7 1 8 9 10 11 12 13 14 NC COM NO 7 1 8 9 10 11 12 13 14 1. Coil operating power Pure DC current should be applied to the coil. The wave form should be rectangular. If it includes ripple, the ripple factor should be less than 5%. However, check it with the actual circuit since the characteristics may be slightly different. 2. Coil connection When connecting coils, refer to the wiring diagram to prevent mis-operation or malfunction. To ensure accurate operation, the voltage on both sides of the coil should be ±5% (at 20°C 68°F) of the nominal coil voltage. Also, please note that the pick-up and drop-out voltages (set and reset voltages) will change depending on operation temperature and conditions of use. Keep the coil allowable voltage ripple ratio to no more than 5%. 3. External magnetic field Since RX-P relays are highly sensitive polarized relays, their characteristics will be affected by a strong external magnetic field. Avoid using the relay under that condition. 4. Cleaning For automatic cleaning, the boiling method is recommended. Avoid ultrasonic cleaning which subjects the relays to high frequency vibrations, which may cause the contacts to stick. It is recommended that alcoholic solvents be used. 5. Soldering 1) Please meet the following conditions if this relay is to be automatically soldered. (1) Preheating: Max. 120°C 248°F (terminal solder surface) for max. 120 seconds (2) Soldering: Max. 260±5°C 500±41°F for max. 6 seconds 2) Please meet the following conditions if this relay is to be soldered by hand. (1) 260°C 500°F for max. 10 seconds (2) 350°C 662°F for max. 3 seconds *In addition, when soldering the case to the PC board, the plating may swell depending on the soldering conditions. 6. Conditions for operation, transport and storage conditions 1) Ambient temperature, humidity, and atmospheric pressure during usage, transport, and storage of the relay: (1) Temperature: –40 to +70°C –40 to +158°F (However, when 60 to 70°C 140 to 158°F, the pulse time is 1 second maximum and ON time is 10% maximum.) (2) Humidity: 5 to 85% RH (Avoid freezing and condensation.) The humidity range varies with the temperature. Use within the range indicated in the graph below. (3) Atmospheric pressure: 86 to 106 kPa Temperature and humidity range for usage, transport, and storage: 2) Condensation Condensation forms when there is a sudden change in temperature under high temperature and high humidity conditions. Condensation will cause deterioration of the relay insulation. 3) Freezing Condensation or other moisture may freeze on the relay when the temperature is lower than 0°C 32°F. This causes problems such as sticking of movable parts or operational time lags. 4) Low temperature, low humidity environments The plastic becomes brittle if the relay is exposed to a low temperature, low humidity environment for long periods of time. Humidity, %R.H. Temperature, °C °F Tolerance range 07 0-40 32 158 -40 (Avoid condensation when used at temperatures higher than 0°C 32°F) (Avoid freezing when used at temperatures lower than 0°C 32°F) /a4dE?H/a6fM=LA,ALE?AI/a2e>/a6f/a6f/a6b 2=CA# 9A@/a6eAI@=O/a2c /a4e/a6fLA/a6d>AH $/a2c & %/a3a# 2/a4d All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.

RX-P (ARXP1) 7. Latching relay 1) To ensure accurate operation of the latching type amidst surrounding temperature changes and other factors that might affect the set and reset pulse times, we recommend a coil impress set and reset pulse width of at least 30 ms at the rated operation voltage. 2) The latching type relay is shipped in the reset position. But jolts during transport or impacts during installation can change the reset position. It is, therefore, advisable to build a circuit in which the relay can be initialized (set and reset) just after turning on the power. 8. Measuring method 50Ω type Connect connectors 1 and 2 respectively to PORT 1 and PORT 2. Perform calibration using the 3.5 mm calibration kit (HP85052B). After calibration, connect the D.U.T. board and measure. However, connectors other than those for measurement should be connected with a 50Ω termination resistor. PC board Dimensions (mm inch) PC board for correction Dimensions (mm inch) Material: Glass PTFE double-sided through hole PC board R-4737 (Panasonic Electric Works) Board thickness: t = 0.8 mm .031 inch Copper plating: 18 µm Connector (SMA type receptacle) Product name: 01K1808-00 (Waka Manufacturing Co., Ltd.) Value has compensation PC board subtracted only for insertion loss. (Eliminate loss of connector and PC board.) 9. Others 1) The switching lifetime is defined under the standard test condition specified in the JIS C 5442 standard (temperature 15 to 35°C 59 to 95°F, humidity 25 to 85%R.H.). Check this with the real device as it is affected by coil driving circuit, load type, activation frequency, activation phase, ambient conditions and other factors. Also, be especially careful of loads such as those listed below.

  • When used for AC load-operating and the operating phase is synchronous, rocking and fusing can easily occur due to contact shifting.
  • When high-frequency opening and closing of the relay is performed with a load that causes arcs at the contacts, nitrogen and oxygen in the air is fused by the arc energy and HNO 3 is formed. This can corrode metal materials. Three countermeasures for these are listed here. (1) Incorporate an arc-extinguishing circuit. (2) Lower the operating frequency (3) Lower the ambient humidity 2) Use the relay within specifications such as coil rating, contact rating and on/ off service life. If used beyond limits, the relay may overheat, generate smoke or catch fire. 3) Be careful not to drop the relay. If accidentally dropped, carefully check its appearance and characteristics before use. 4) Be careful to wire the relay correctly. Otherwise, malfunction, overheat, fire or other trouble may occur. 5) If a relay stays on in a circuit for many months or years at a time without being activated, circuit design should be reviewed so that the relay can remain non-excited. A coil that receives current all the time heats, which degrades insulation earlier than expected. A latching type relay is recommended for such circuits. 6) If silicone materials (e.g., silicone rubbers, silicone oils, silicone coating agents, silicone sealers) are used in the vicinity of the relay, the gas emitted from the silicone may adhere to the contacts of the relay during opening and closing and lead to improper contact. If this is the case, use a material other than silicone. No. Product name Contents

1 Agilent

2.4mm-3.5mm female .095inch-.138inch female

2 SUHNER

3.5mm-3.5mm male .138inch-.138inch male PORT2 PORT1 Network analyzer Agilent Technologies E8363B 1 2 1 2 Solder surface-mount (SMA) type connectors. a .945 .630 b 6.0 .236 2.0 .079 .337 (a+b) .337 (a+b) 8.57 (a+b) 8.57 (a+b) Solder surface-mount (SMA) type connectors. .630 6.0 .236 2.0 .079 For general cautions for use, please refer to the “General Application Guidelines”. /a4dE?H/a6fM=LA,ALE?AI/a2e>/a6f/a6f/a6b 2=CA# 9A@/a6eAI@=O/a2c /a4e/a6fLA/a6d>AH $/a2c & %/a3a# 2/a4d All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.