Features
- PERFORMS FUNCTIONS COMMON TO MIL-STD-1553
- ENCODE
- DECODE
- ADDRESS RECOGNITION
- THREE STATE PARALLEL I/O
- SELF TEST CAPABILITY
- MIL-PRF-38534 COMPLIANT CIRCUITS AVAILABLE
- SMALL SIZE – REPLACEMENT FOR DDC8937 MODEL NUMBER
- 5V DC OPERATION
- FULL MILITARY (-55°C TO +125°C) TEMPERATURE RANGE General Description The Aeroflex Circuit Technology Model ARX2412 Manchester Converter is a self contained, 48pin, triple-in-line hybrid package designed to perform: encode, decode, logic and control functions in a MIL-STD-1553, A and B multiplex data system. It Provides the necessary interface between transceivers and a three state parallel 16 bit bus of the protocol logic section of a subsystem remote terminal or controller. Figure 1 – FUNCTIONAL BLOCK DIAGRAM Data Terminal Manchester Converter ARX2412 for MIL-STD-1553 BITS 5-15 BITS 0-4 BITS 0-4 CLK
3 STATE ENABLE
3 STATE LATCHES
3 STATE OUT
3 STATE IN
(ADDRESS REGISTER CLEAR) VU INT (VALID ADDRESS) SACK (SYSTEM ACKNOMLEDGE) TO / FROM 16 BIT PARALLEL BUS BITS DB0 - DB15 OSEL (OUTPUT SELECT) TRANSMITTER BUSY SYNC SELECT ENCODER ENABLE VALID WORD FI EI DC E R T A E ROFL E X L A BS IN C .ISO9001 TRANSMITTER SECTION TX DATA TX DATA DATA
5 BITS
B0-B4, MSB-LSB SERIAL VALID REGISTER WORD
Aeroflex Circuit Technology SCD2412 REV C 10/19/98 Plainview NY (516) 694-67002 Theory of Operation This section provides a detailed functional description of the MIL-STD-1553A/B Command/Response Manchester II converter (hereinafter referred to as Converter) and is intended for use with the timing diagrams shown in Figures 2 and 3. GENERAL POWER ON CLEAR (POC): A logic "0" input applied at turn-on initializes all of the internal logic. This signal clears the encoder/decoder internal counters and initializes the encoder and decoder functions. This can also be used to abort a transmission. DECODER OPERATION An seen in Figure 1, Functional Block Diagram, the converter interfaces directly with the MIL-STD-1553 transceiver by mans of four lines, namely Tx DATA, Tx DATA , Rx DATA, and Rx DATA . In the decode mode of operation, the converter normally needs logic lows (OFF Mode) on Rx DATA and Rx DATA . Whenever the MIL-STD-1553 data bus is active, the MIL-STD-1553 transceiver will output signals that are similar to those illustrated in Figure 2 (Rx DATA and Rx DATA ) to the converter. Approximately 5µsec after the converter has detected the first transition change in, the Rx DATA input line, the Received Busy output line will activate from a low to high state and remain high for 16µsec. During this period, the internal Encoder/Decoder is shifting serial data out and the information is being clocked into an internal 16 bit serial to parallel shift register. The Receiver Busy line will go low after 16µsec, and will remain low for 4µsec if another 20 bit word immediately follows the first word. The second word will cause Receiver Busy to go high for another 16µsec time interval, This sequence continues until no additional information is to be processed. At approximately the same time as the first Receiver Busy low to high transition, the Receiver Sync Type line will go high if a command or status sync field is detected by the internal decoder. It too will remain high for 16µsec. If a data sync field is detected by the decoder, the Receiver Sync Type line will remain in the low state. During the receiver busy time the decoder shifts serial data out to the serial to parallel shift register, regardless of whether the data is valid or not. However, the stored data is not shifted into the 3-state output buffer unless a Valid Word indication occurs. This signal is designated Valid Word. Valid Word performs three functions within the converter: strobes the 16 bit parallel word into the 3-state output buffer, strobes the address recognition function and indicates to the subsystem user that a valid 16 bit word is now ready to be processed. A high to low transition on the Valid Word line will indicate the receipt of a Valid Word. The first five bits of a 16 bit command word represent the terminal address. The bits are decoded, shifted through the serial to parallel shift register and compared to the five lines in the address recognition register (own address, B0 (MSB) thru B4). If a command word is received, and the own address lines and decoder remote terminal address bits correspond, and Valid Word occurs, then a Valid Address Signal (VU INT ) will Specifications Parameter Units Value External Clock Oscillator Type (12MHz) TTL As per MIL-STD-1553 A/B long and short term Power Supply Characteristics Voltage Input Current Vdc mA +5.0 ±5% 200 max Thermal Characteristics Operating Current Storage Current -55 to +125 (Case Temperature) -55 to +150 Physical Characteristics Weight Size oz in. 0.7 (20g) approx. 1.7 x 1.1 x 0.2 (43 x 28 x 5.1 mm)
Aeroflex Circuit Technology SCD2412 REV C 10/19/98 Plainview NY (516) 694-67003 occur going from a logic "1" to logic "0". This signal transitions at the same time as Valid Word. Upon detecting a Valid Word output, the user subsystem must respond with a signal called System Acknowledge (SACK). A high to low input to the converter will set both Valid Word and VU INT (if occurred) to their original high states. These two outputs are then ready to analyze the next received 20 bit word. At the same time, SACK will enable the output 3-state buffer for data readout on the 16 parallel data lines. The user subsystem has up to 20µsec to process the data before the next 20 bit word is ready to be latched in the output buffer. A return to the high state on SACK will cause the 3-state output buffer to return to the high impedance state, completing the conversion of one 20 bit word. The command sync clear input signal is required to initialize the converter internal logic, set by detection of command or status sync. It also resets Valid Word logic. This input signal must be applied each time a receiver sync type transitions, low to high, occurs but must not occur until the Valid Word transitions high to low. Under certain circumstances, valid address transition may not occur after a valid sync field is recognized. ENCODER OPERATION In the encode mode of operation (Figure 3), the converter normally provides logic highs (off mode) on Tx DATA and Tx DATA . These two signal lines provide output data in complementary serial phase modulated format to the MIL-STD-1553 transceiver during a transmission. To effect a transmission from the converter, the sequence of events is to first load 16 bit parallel data into the 3-state input buffer. This is achieved by the presentation of an input pulse of logic zero on the Output Select (OSEL) line. Data to the converter must be stable when the OSEL occurs. When the XMTR busy signal goes from low to high, the OSEL may be activated to load the next 16 bit word in preparation for transmission. Next, the user subsystem must bring the Encoder Enable line high to initiate a transmission. Encoder Enable can be conveniently triggered from the leading or trailing edge of OSEL but must remain high for 1.0µsec after the trailing edge of OSEL. If the Encoder Enable line is allowed to remain high, successive transmissions will result. The transmitter busy line will go high for 16µsec every time a 20 bit word is processed through the internal Encoder. Transmitter Busy indicates to the user subsystem that control logic is shifting data from the parallel to serial data buffer to the bi-phase encoder during a transmit cycle. To terminate a transmission, the Encoder Enable line must be brought low on or before the high to low transition of the current transmitter busy signal. The remaining signal that is required to make the converter encoder operate properly is the Sync Select input signal. Sync Select is an input from the user subsystem for the purpose of setting the appropriate sync field polarity to correspond with the word to be transmitted. A high on this line will create a command or status sync field, and a low will result in a data sync field. Initially it should be set to a Logic "1" before the encoder enable line is set high, and remain high no later than the high to low transition of the transmitter busy signal. Appplication and Operation Information General LOGIC COMPATIBILITY Direct logic compatibility exists with transceiver types which have logical low receiver outputs at times when the bus is not active, such as Models ARX3402/4402 and ARX3411/4411. Use with logical high receiver output devices, such as Aeroflex Models ARX3231/3232 or ARX3404/4404 will necessitate utilization of inverters between transceiver RX outputs and Model ARX2412 RX inputs. POWER ON CLEAR (POC ) A low on this input line resets all internal registers and initializes the Manchester Converter for transmission of complete messages. DATA I/O (DB0-DB15) The 16 bits of input and output are three state lines. Impedance of the receiver section latches is high during transmit cycle. Latched data can be retained for up to 20µsec. during input of next data word. TERMINAL ADDRESS LINES (B0-B4) Addressing the 5 bit address lines is done by hard wiring. Internal pull up resistors allow logic "1" lines to be open circuited. Logic "0" lines must be tied to ground. When a valid command word incorporating the proper address is received at the input it will cause VU INT to go low.
Aeroflex Circuit Technology SCD2412 REV C 10/19/98 Plainview NY (516) 694-67004 SELF TEST COMPATABILITY Self test may be accomplished using a wraparound mode. This is done by switching TX DATA and TX DATA through external multiplexers into RX DATA and RX DATA . During this operation the transceiver must be inhibited to avoid extraneous transmission on the bus. Decoder Operation RECEIVER DATA (RX DATA) and (RX DATA ) Inputs from a compatible transceiver in complementary serial biphase form. RECEIVER BUSY (RCVR BUSY) Outputs status of received information when data is being transferred into the receiver data buffer registers after a valid sync has been received. The line will go high when busy and remain so until the completion of the receive cycle. RECEIVER SYNC TYPE Outputs the sync field polarity of each input word and is valid when (RCVR BUSY) signal is high. A high indicates command or status sync; a low indicates data sync. VALID WORD Transitions from high to low after receipt of a valid sync, 16 data bits and an odd parity bit. Transition back to high indicates that data is now available in the three state output register. SYSTEM ACKNOWLEDGE (SACK ) An input transistion from high to low enables readout transfer from output registers onto the parallel data output lines. Duration should be approximately 2µsec. The leading edge transition resets VALID WORD and VU INT to high, permitting a new receive cycle. VALID ADDRESS (VU INT) Output goes low only upon validation of input word and recognition of its internal terminal address. COMMAND SYNC CLEAR: This input low must be provided 2µsec after each RECEIVER SYNC TYPE low to high transition, and must be no wider than 1µsec. Encoder Operation OUTPUT SELECT (OSEL ) Logic low transfers input data into internal buffer registers for processing. SYNC SELECT Prior to initiation of a transmission this line should be set high. Retention of high establishes a command or status sync and a low will produce a data sync. The line should be brought low prior to the high to low transition of the TRANSMITTER BUSY line. For successive transmissions refer to the Transmitter Section Timing Diagram. ENCODER ENABLE A logic high starts an encoder cycle. Retention of high permits successive transmissions, which can be avoided by transitioning, to low at least lµsec before XMTR BUSY transition. TRANSMITTER BUSY (XMTR BUSY) High is busy indicating that data is being shifted from the input data buffer to the encoder. TRANSMIT DATA (TX DATA) and (TX DATA) Output from the encoder in complementary serial form. Positive and negative excursions represent digital "1"s and "0"s.
Aeroflex Circuit Technology SCD2412 REV C 10/19/98 Plainview NY (516) 694-67005 1MHZ CLOCK POWER ON CLEAR POC (INPUT) RX DATA (INPUT) RX DATA (INPUT) RECEIVER SYNC TYPE RECEIVER BUSY VALID WORD VU INT (OUTPUT) VALID ADDRESS SACK (INPUT) SYSTEM ACKNOWLEDGE COMMAND SYNC CLEAR (INPUT) 1MHZ CLOCK BIT TIMES POWER ON CLEAR POC (INPUT) OUTPUT SELECT (INPUT) SYNC SELECT (INPUT) ENCODER ENABLE (INPUT) XMTR BUSY (OUTPUT) TX DATA (OUTPUT) TX DATA (OUTPUT) (OUTPUT) (OUTPUT) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 Figure 3 – TRANSMITTER SECTION TIMING FOR ENCODE OPERATION Figure 2 – RECEIVER SECTION TIMING FOR DECODE OPERATION 500ns NOM 500ns NOM 50ns MIN to 20µs MAX 100ns MIN 4µs NOM
5 BIT
5µs NOM DATA SYNC COMMAND SYNC BIT TIMES (OUTPUT) 25ns MIN to 1µs MAX2 µS DO NOT CUE FROM VALID WORD Note: A Command Sync Clear must be provided for every Receiver Sync Type low to high transition. 100 ns MIN 1µs NOM 100ns MIN (OR DELAY) 1.0 µs MIN BRING LOW NO LATER THAN XMTR BUSY HIGH TO LOW Drop Enable 1µs MIN Before XMTR Busy To Stop Next Word 16µs NOM DATA SYNC COMMAND SYNC 1µs NOM 000000000000000000 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 0 0 0 0 0 0 0 0 0 0 0 0 0 111 2 3 41 5 - - - - 4µs NOM 16µs NOM 16µs NOM 16µs NOM 16µs NOM5µs NOM 2µs NOM 2µs NOM COMMAND SYNC DATA SYNC DON’T CARE 0.5 µs MAX SEND DATA SEND DATA 1.0 µs MIN 3.5µs NOM TAKE DATA TAKE DATA 16µs NOM
Aeroflex Circuit Technology SCD2412 REV C 10/19/98 Plainview NY (516) 694-67006 Pin # Function Input / Output 1 - 16 Parallel Data (DB0 - DB15) Both
17 No Connection
19 GND
20 DSC Out Output
21 Power On Clear (POC ) Input
22 Transmitter Busy (XMTR BUSY) Output
23 Receiver Busy (RCVR BUSY) Output
24 Sync Select Input
25 Encoder Enable Input
26 System Acknowledge (SACK ) Input
28 Output Select (OSEL ) Input
29 No Connection
30 Transmitter Data (TX DATA) Output
31 Transmitter Data (TX DATA) Output
32 Receiver Data (RX DATA) Input
33 Receiver Data (RX DATA ) Input
34 Valid Word Output
35 Clock 2 Input (12 MHz) Input
36 Clock 1 Output (12 MHz) Output
37 Clock 1 Input (12 MHz) Input
38 Clock Select (CK SEL)
Logic "1" = Clock 1 Select Logic "0" = Clock 2 Select Input
39 Valid Address (VU INT) Output
40 No Connection
41 Command Sync Clear Input
42 Receive Sync Type Output
43 Case GND
44 - 48 Own Address (B0 = MSB to B4) Input
Aeroflex Circuit Technology SCD2412 REV C 10/19/98 Plainview NY (516) 694-67007