ORDERING INFORMATION
- Standard type High capacity SSR up to 40A with wide variation AQ-N RELAYS Type Load current Load voltage Part No. Zero-cross type 10A 75 to 250V AC AQN111 15A AQN211 20A AQN311 25A AQN411 40A AQN611 Random type 10A 75 to 250V AC AQN121 15A AQN221 20A AQN321 25A AQN421 40A AQN621
FEATURES
- Five types available from 10A to 40A 2. Built-in varistor 3. Includes operation LED (red) 4. Dielectric voltage of 4,000V 5. 4 to 32V DC input voltage 6. Both zero-cross and random types available TYPICAL APPLICATIONS 1. Molding machine (heater control) 2. Temperature controlled bath (heater control) 3. Printing machines (heater control) 4. Wrapping and packing machine (heater control) 5. Machine tools (Motor control) Compliance with RoHS Directive AQ-N Solid State Relays Load current 1: 10 A 2: 15 A 3: 20 A 4: 25 A 6: 40 A AQN Load voltage 1: 75 to 250 V AC, Zero-cross 2: 75 to 250 V AC, Random Function Nil: VL: None Built-in varistor With LED indication Built-in varistor and with LED indication Input voltage 1: 4 to 32 V DC All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
- With LED indication type 3. With varistor type 4. With varistor and LED indication type Standard packing; carton: 2 pcs., case: 100 pcs. 5. Accessories RATINGS 1. Ratings (Measurement condition: at 20°C 68°F, Input ripple: 1% or less) 1) Zero-cross type Notes: *1. Please refer to REFERENCE DATA, “3. Input current vs. input voltage”. *2. Please refer to REFERENCE DATA, “1. Load current vs. ambient temperature”. *3. Please refer to REFERENCE DATA, “2. Non-repetitive surge current vs. carrying time”. *4. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”. Type Load current Load voltage Part No. Zero-cross type 10A 75 to 250V AC AQN111L 15A AQN211L 20A AQN311L 25A AQN411L 40A AQN611L Random type 10A 75 to 250V AC AQN121L 15A AQN221L 20A AQN321L 25A AQN421L 40A AQN621L Type Load current Load voltage Part No. Zero-cross type 10A 75 to 250V AC AQN111V 15A AQN211V 20A AQN311V 25A AQN411V 40A AQN611V Random type 10A 75 to 250V AC AQN121V 15A AQN221V 20A AQN321V 25A AQN421V 40A AQN621V Type Load current Load voltage Part No. Zero-cross type 10A 75 to 250V AC AQN111VL 15A AQN211VL 20A AQN311VL 25A AQN411VL 40A AQN611VL Random type 10A 75 to 250V AC AQN121VL 15A AQN221VL 20A AQN321VL 25A AQN421VL 40A AQN621VL Type Part No. Packaged quantity Standard heat sink (10A, 15A and 20A) AQP-HS-J10A 5 in a carton, 20 in a case Standard heat sink (25A) AQP-HS-30/40A 5 in a carton, 20 in a case Standard heat sink (40A) AQP-HS-J25A No carton, 5 in a case Slim heat sink (45mm wide) (Mountable on a DIN rail) AQP-HS-SJ20A No carton, 8 in a case DIN rail mounting plate AQP-DP 10 in a carton, 100 in a case Terminal cover AQP-NPC 2 in a carton, 100 in a case Item Type 10A 15A 20A 25A 40A Remarks Part No. AQN111 AQN111L AQN111V AQN111VL AQN211 AQN211L AQN211V AQN211VL AQN311 AQN311L AQN311V AQN311VL AQN411 AQN411L AQN411V AQN411VL AQN611 AQN611L AQN611V AQN611VL Input side Input voltage 4 to 32V *1 Input current Max. 20mA *1 Drop-out voltage Min. 1V Output side Max. load current 10A 15A 20A 25A 40A *2 Load voltage 75V to 250V Frequency 45Hz to 65Hz Non-repetitive surge current 100A 150A 200A 250A 400A In one cycle at 60Hz *3 Max. “OFF-state” leakage current Max. 10mA at 60Hz Max. “ON-state” voltage drop 1.6V at Max. carrying current Min. load current 100mA *4 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
2) Random type Notes: *1. Please refer to REFERENCE DATA, “3. Input current vs. input voltage”. *2. Please refer to REFERENCE DATA, “1. Load current vs. ambient temperature”. *3. Please refer to REFERENCE DATA, “2. Non-repetitive surge current vs. carrying time”. *4. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”. 2. Characteristics (Measurement condition: at 20°C 68°F, Input ripple: 1% or less) 1) Zero-cross type 2) Random type Item Type 10A 15A 20A 25A 40A Remarks Part No. AQN121 AQN121L AQN121V AQN121VL AQN221 AQN221L AQN221V AQN221VL AQN321 AQN321L AQN321V AQN321VL AQN421 AQN421L AQN421V AQN421VL AQN621 AQN621L AQN621V AQN621VL Input side Input voltage 4 to 32V *1 Input current Max. 20mA *1 Drop-out voltage Min. 1V Output side Max. load current 10A 15A 20A 25A 40A *2 Load voltage 75V to 250V Frequency 45Hz to 65Hz Non-repetitive surge current 100A 150A 200A 250A 400A In one cycle at 60Hz *3 Max. “OFF-state” leakage current Max. 10mA at 60Hz Max. “ON-state” voltage drop 1.6V at Max. carrying current Min. load current 100mA *4 Type 10A 15A 20A 25A 40A Remarks Part No. AQN111 AQN111L AQN111V AQN111VL AQN211 AQN211L AQN211V AQN211VL AQN311 AQN311L AQN311V AQN311VL AQN411 AQN411L AQN411V AQN411VL AQN611 AQN611L AQN611V AQN611VL Operate time, max. 1/2 cycle of voltage sine wave + 1ms Release time, max. 1/2 cycle of voltage sine wave + 1ms Insulation resistance, min. 100M Ω between input and output at 500 V DC Breakdown voltage 4,000 Vrms between input and output; 2,500 Vrms between input, output and case for 1min. Vibration resistance (Functional) 10 to 55Hz double amplitude of 1.5mm X, Y , Z axes Shock resistance (Functional) Min. 980 m/s
2 X, Y , Z axes
Ambient temperature –20 °C to +80°C –4°F to +176°F*2 Non-condensing at low temperaturesStorage temperature –25 °C to +85°C –13°F to +185°F Operational method Zero-cross (Turn-ON and Turn-OFF) Type 10A 15A 20A 25A 40A Remarks Part No. AQN121 AQN121L AQN121V AQN121VL AQN221 AQN221L AQN221V AQN221VL AQN321 AQN321L AQN321V AQN321VL AQN421 AQN421L AQN421V AQN421VL AQN621 AQN621L AQN621V AQN621VL Operate time, max. 1ms Release time, max. 1/2 cycle of voltage sine wave + 1ms Insulation resistance, min. 100M Ω between input and output at 500 V DC Breakdown voltage 4,000 Vrms between input and output; 2,500 Vrms between input, output and case for 1min. Vibration resistance (Functional) 10 to 55Hz double amplitude of 1.5mm X, Y , Z axes Shock resistance (Functional) Min. 980 m/s Ambient temperature –20 °C to +80°C –4°F to +176°F Non-condensing at low temperaturesStorage temperature –25 °C to +85°C –13°F to +185°F Operational method Random Turn-ON, Zero-cross Turn-OFF All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
- Load current vs. ambient temperature Use load current within range specified in the figure below. Tested condition With external heat sink 1) (1) 10A, 15A, 20A type Shown with standard heat sink (AQP801) (2) Shown with 25A type standard heat sink (AQP804) (3) Shown with 40A type standard heat sink (AQP806) (4) In the case of the AQP812 slim heat-sink types, characteristics data are available for each type. Please refer to (6). 2) If attached to a heat sink, use a heat conductive compound (Ex. Toshiba silicone YG6111 or TSK5303) of similar coating to improve cooling. Without external heat sink If the mounting surface is not metallic and a heat sink is not used, expose the bottom surface and plate surface to improve heat dissipation. (1) 10A type 0 0 -20 20 40 60 80 100 Ambient temperature, °C Load current, A When using AQP-HS-J10A or a steel plate of 100×100×t0.8 (mm) or greater When using as stand-alone (2) 15A type (3) 20A type (4) 25A type 100 80 60 40 20 -20 0 Ambient temperature, °C Load current, A When using a steel plate of 100×100×t1.6 (mm) or greater When using as stand-alone When using AQP-HS-J10A or a steel plate of 150×150×t1.6 (mm) or greater Ambient temperature, °C Load current, A 100 80 60 40 20 -20 0 When using as stand-alone When using a steel plate of 75×75×t1.6 (mm) or greater When using AQP-HS-J10A When using a steel plate of 100×100×t1.6 (mm) or greater When using a steel plate of 150×150×t1.6 (mm) or greater 100 80 60 40 20 -20 0 When using a steel plate of 150×150×t1.6 (mm) or greater When using a steel plate of 100×100×t1.6 (mm) or greater When using as stand-alone When using AQP-HS-30/40A When using AQP-HS-J10A Ambient temperature, °C Load current, A (5) 40A type (6) Data when mounted on an AQP-HS-SJ20A slim heat sink 2. Non-repetitive surge current vs. carrying time 100 80 60 40 20 -20 0
0 When using a steel plate
of 150×150×t1.6 (mm) or greater When using a steel plate of 100×100×t1.6 (mm) or greater When using a steel plate of 75×75×t1.6 (mm) or greater When using as stand-alone When using AQP-HS-J25A When using AQP-HS-30/40A Ambient temperature, °C Load current, A 02 0 4 0 100 80 60
40 A type
25 A type
20 A type
15 A type
10 A type
Ambient temperature, °C Load current, A 100 500 400 300 200 11 0 100 No. of cycles at 60 Hz Non-repetitive surge current, A
- Input current vs. input voltage 10A, 15A, 20A, 25A, 40A common 10 15 502 0 2 5 3 5 30 Input voltage, V Input current, mA Without LED With LED All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
DIMENSIONS (mm inch) ACCESSORIES The CAD data of the products with a CAD Data mark can be downloaded from: http://panasonic-electric-works.net/ac * The right figure is the LED indication type. The standard type has the same dimensions. External dimensions 58.0 4.5 dia. .177 dia. 47.5 43.2 22.020.0 27.0 max. 2.283 1.870 1.701 2-M3 2-M4 .866.787 1.063 max. Schematic Mounting dimensions Load power source1 Input power source _ Load 1.870 +.008 −.004 47.5 +0.2 −0.1 2-.069 dia. or M4 2-4.3 dia. or M4 CAD Data AQP-HS-SJ20A Slim Heat Sink AQP812 4.6×5.6 elliptical hole .181×.220.181 dia. 4.6 dia. 5-M4 (Effective screw depth: 6mm .236inch) 47.6 1.874 100 1.772 1.575 3.937 3.543 3.071 1.181 1.181 70707 “A” part .063 1.6 .236 3.071 3.268 Mounting dimensions 2-.181 dia. or M4 2-4.6 dia. or M4 90±0.2 3.543±.008 .236 General tolerance: ±1.0 ±.039 Note: When using on a DIN rail, please install so that the “A” part is on top. CAD Data AQP-HS-J10A Standard Heat Sink 1.5 11.1 1.5 4.4 .173 .059 .079 .079 .437 .059 3-M4 R2.2 .087 4.4 .173 3.543 100 3.937 47.6 1.874 1.181 1.969 33.3 1.311 2.126 3.150 100+0.5−1.5 +.020−.0593.937 1.772 28.5 1.122 24.5 .965 .354 Mounting dimensions 4-M4 or 4.4 dia. 50±0.2 90±0.1 4-M4 or .173 dia. 1.969±.008 3.543±.004 CAD Data AQP-HS-30/40A Standard Heat Sink 4.4 4.4 54 100+0.5 −1.5 3.937+.020 −.059 33.3 47.6 150 24.5 1.5 11.1 1.5 28.5 R 2.2 .0873-M4 3.543 .173 .173 1.969 2.126 3.150 1.311 1.874 2.205 5.906 .965 .059 .079 .079 .437 .059 1.122 1.772 .354 General tolerance: ±0.5 ±.020 Mounting dimensions 4-M4 or 4.4 dia. 50±0.2 90±0.1 4-M4 or .173 dia. 1.969±.008 3.543±.004 CAD Data All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQP-HS-J25A Standard Heat Sink 120 .079 100 .276 3-M4 132 5.197 142 4.724 3.937 3.228 2.520 1.811 5.591 .512 .197 1.181 2.047 .118 150 5.906 119 4.685 47.5 1.870 4-R2.5 4-R.098 Mounting dimensions 4-M4.5 or .197 dia. 4-M4.5 or 5 dia. 132±0.1 5.197±.004 119±0.1 4.685±.004 CAD Data AQP-DP DIN Rail Mounting Plate General tolerance: ±0.5 ±.020 18.1 47.6 13.6 3.386 1.732 .713 2.765 2.205 1.874 .535 AT8-DLA1 Mounting Rail 15 5 510 1,000 5.5 1.5 2415 40-5.5×15 slot 15 10 15 7.5 2.75R .591.197 .394 39.37 .217 1.378 .059 1.063 40-.217×.591 slot .197 .295 CAD Data CAD Data ATA4806 Fastening Plate 10ATA4806 UP .472 1.969 .394 .394 AQP-NPC Terminal Cover 4-7 dia. 44.6 27.9 43.2 25.4 2 57.5 1.54-.276 dia. 1.756 .394 1.098 1.701 1.000 .079 2.264 .945 .059 CAD Data CAD Data All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Recommended Temperature Controllers For Cautions for Use 48mm 56mm 1.890inch 2.205inch 48mm 1.890inch <KT4H Temperature Controller> Our temperature controller is recommended for use with our Solid State Relays.
- Data can be collected using the RS485 communications interface via a PLC.
- Improved visibility using a negative type LCD and backlight.
- Depth-wise length (chassis dimension) is 56 mm 2.205 inch. Substitute part numbers *For detailed product information about temperature controllers, please refer to our website: http://panasonic-denko.co.jp/ac/e/fasys/component/temperature_controller/ Power supply Control output Part No. 100 to 240 V AC Relay contact AKT4H111100 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.