Features

  • Medical safety approvals
  • Home healthcare approval
  • Energy efficiency level VI & EU CoC tier 2 compliant
  • 4th edition medical EMC
  • IP22 environmental rating
  • Class I and class II versions
  • <0.15W standby power
  • 0°C to 60°C operation
  • Low earth leakage current
  • 3 year warranty AC-DC POWER SUPPLIES Healthcare Medical Diagnostics Home Healthcare CONVECTION COOLED250W

Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 12 48 VDC See Models and Ratings table Initial Set Accuracy ±2 % 50% load Minimum Load No minimum load required Start Up Delay 1 1.5 s Start Up Rise Time 30 35 ms 115VAC Hold Up Time 10 ms Full load and 115/230VAC Line Regulation ±0.5 % 90-264 VAC Total Regulation See Model and Ratings table, includes inisital set accuracy, line and load regulation Transient Response 4 % Recovery within 1% in less than 500µs for a 50-75% and 75-50% load step Ripple and Noise 1.0 % pk-pk 20MHz bandwidth and 10µF electrolytic capacitator in parallel with 0.1µF ceramic capacitator Overshoot 5 10 % At turn on/turn off Overload Protection 130 170 % Overvoltage Protection 110 180 % Recycle mains to reset Short Circuit Protection T rip and restart (hiccup), auto resetting Temperature Coefficient 0.2 %/°C Patient Leakage Current 50 100 µA 264VAC, 60Hz Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 85 264 VAC Derate linearly from 100% load at 90VAC to 85% load at 85VAC Input Frequency 47 63 Hz Power Factor >0.9 EN61000-3-2 class A Input Current 2.9/1.3 A 115/230VAC Inrush Current 150 A 230VAC cold start, 25°C Earth Leakage Current 300 500 µA 264VAC, 60Hz, class I versions only No load Input Power 0.15 W Input Protection T5A/250V Internal fuse fitted in line and neutral.

Characteristic Minimum Typical Maximum Units Notes & Conditions Efficiency 91 92 % See Models and Ratings table Isolation: Input to Output Input to Ground Output to Ground

4000 VAC 2 x MOPP

1800 VAC 1 x MOPP (Class I versions only)

500 VAC Class I versions only

Mean Time Between Failure >300 khrs TELCORDIA SR-322 @ 25°C Weight 1.9 (860) lb(g) Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature 0 +60 °C Derate linearly from 100% load at 40°C to 50% load at 60°C, safety approved to 40°C Cooling Natural convection Operating Humidity 95 %RH Non-condensing Storage Temperature 80 °C Operating Altitude 5000 m Shock IEC68-2-27 , 30 g, 11 ms half sine, 3 times in each of 6 axes Vibration IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep, 60 mins for each of 3 axes Derating Curve 100 80 9085 264 Input Voltage (VAC) Output Power (%) 60% 20% 40% 80% Ambient Temperature (ºC) Output Power (%) 100% 40 6020

AC-DC POWER SUPPLIESAQM250 Series EMC: Emissions Phenomenon Standard T est Level Notes & Conditions Conducted EN55011 Level B Radiated Harmonic Currents EN61000-3-2 Class A Voltage Flicker EN61000-3-3 Safety Approvals Safety Agency Standard Notes & Conditions UL ANSI/AAMI ES 60601-1 CSA CSA C22.2 No. 60601-1 TUV EN60601-1 / EN60601-1-11 60601-1-11 is only for Class II versions CB IEC60601-1 / IEC60601-1-11 CE Meets all applicable directives UKCA Meets all applicable legislation EMC: Immunity Phenomenon Standard T est Level Criteria Notes & Conditions ESD Immunity EN61000-4-2 4 A ±8kV contact / ±15kV air discharge Radiated Immunity EN61000-4-3 10V/m A EFT/Burst EN61000-4-4 2 A Surge EN61000-4-5 Installation class 3 A Conducted EN61000-4-6 6V A Magnetic Field EN61000-4-8 4 A Dips and Interruptions EN60601-1-2 Dip: 30% 25 AC Cycles A/B 115VAC and above/100VAC Int: 100% 0.5 AC Cycles A Int: 100% 1.0 AC Cycles B Int: 100% 250 AC Cycles B

Notes:

526 Oct 2022

3.35 (85.0) Side View Top View 7.2 (183±1) 39.3 (1000.0) 1.38 (35.0) 1.9 (50.0±5) P1 (RTN) P2 (RTN) P3 (RTN) P4 (+Vout) P5 (+Vout) P6 (+Vout) Output cable plug pin assignment IEC320-C14 IEC320-C18 op/g2462onal class II input 2. Weight: 1.9lbs (860g) approx. 3. Output connector: 6 pin Molex Mini-Fit series with 39-01-2060 housing and 39-00-0077 terminals. Mates with Molex series 5566 headers or equivalent. AC-DC POWER SUPPLIES