Made to Measure. Good Will Instrument Co., Ltd.

FEATURES

  • Wide Output Voltage/Frequency Variable Range * True RMS Meter Voltage/Frequency Memory Saves/Recalls 4 Sets of * Stable and Low-Distortion Output Waveforms * Software Calibration to Ensure Accuracy * Panel-Lock Function to Prevent Operation Error * Over Current Protection and Over Temperature Protection * Frequency, Volt, Amp, Watt and Power Factor Display TYPE OUTPUT CAPACITY 300 VA OUTPUT VOLTAGE 0.0~300.0 VAC, 0.1V step (110,220V selectable) OUTPUT MAX. CURRENT FREQUENCY 45.0~500.0Hz (50Hz, 60Hz selectable) WAVEFORM Sine wave, 0 ~ 150V the above 22V 0.5% THD (resistance load) 0 ~ 300V the above 44V 0.5% THD (resistance load) LINE VOLTAGE REGULATION <0.1% LOAD REGULATION 0.5% + 0.1V SAVE/RECALL 4 settings, Save/Recall operated by hand PROTECTION Short-circuit protection, panel- lock, over temperature protection, current overflow MEASUREMENT Range 0.0~999.9Hz 0.0~380.0V 0.000~2.000A 1.80~35.00A 0.0~360.0W 320.0~3500.0W 0~150V 0~300V Frequency Counter RMS Volt-Meter RMS Amp-Meter Wattage Meter 500 VA 1k VA

1.3 Arms

2.1 Arms

4.2 Arms

2.6 Arms

8.4 Arms

0.1Hz 0.1V 1.0mA 0.01A 0.1W 1.0W 0.1Hz (1% of rdg + 1digit) (1% of rdg + 5digits) (1% of rdg + 20digits) (1.5% of rdg + 5digits) (1.5% of rdg + 1digit) APS-9301 APS-9501 APS-9102 POWER SOURCE OPERATION TEMPERATURE/HUMIDITY ACCESSORIES : DIMENSION 430(W) x 137(H) x 500(D)mm WEIGHT Approx. 20kg 430(W)x225(H)x500(D)mm Approx. 25kg Approx. 35kg AC 115V/230V 15%, 47~63Hz, single phase ~+40 ; <80% (non-condensing) User manual x 1 , Power cord x 1 APS-9102 1000VA A.C. Power Supply APS-9501 500VA A.C. Power Supply APS-9301 300VA A.C. Power Supply A.C. POWER SOURCE SPECIFICATIONS APS-9102 APS-9501 Rear Panel The APS-Series are dual output, 300 to 1000VA linear AC power supplies. To protect the APS-Series and loads from unexpected conditions, over current, over temperature and short-circuit protection are standard. High accuracy and low distortion are maintained at true RMS and < 0.5% THD, respectively. The key lock feature prevents tampering and the three separate LED displays simultaneously show frequency, voltage and current to enable easy operation. Configuration is simplified with the store/recall functions for output settings. Software calibration reduces maintenance overhead. The APS-Series are suitable for medium-sized laboratories and production test applications requiring high accuracy and security.

ORDERING INFORMATION