PXP - Series Simply Reliable PPX-1005 10V 50W PPX-2002 20V 40W PPX-2005 20V 100W PPX-3601 36V 36W PPX-3603 36V 108W PPX-10H01 100V 100W Ext I/O

APPLICATIONS

FEATURES

The PPX-Series programmable high-precision DC power supplies include six models; PPX- 1005(10V/5A/50W), PPX-2002(20V/2A/40W), PPX-2005(20V/5A/100W) ), PPX- 3601(36V/1A/36W), PPX-3603(36V/3A/108W), and PPX-10H01(100V/1A/100W). This series has the output low noise (0.35mVrms) and fast transient response characteristics (<50µs) of conventional linear power supplies. It also provides constant voltage and constant current priority output modes, and the series can also set the voltage and current rising/falling slew rates separately, and the delay time for the output to be turned on and off. The PPX-Series has four current levels and two voltage levels to provide users with high-precision measurements, and via the Data Logger function, the measurement records can be stored in the USB for long-term measurement and recording of IoT devices, portable devices, wearable devices, and sensor components. In order to extend the use time of portable devices and wearable devices, manufacturers are not only committed to improving the operating efficiency of the circuit, but also reducing standby power consumption as much as possible. In order to satisfy users’ low-power measurement applications, GW Instek has launched the PPX-Series with current measurement resolutions (0.1µA, 1µA, 10µA, 0.1mA) and voltage measurement resolutions (0.1mV, 1mV) to provide power for portable devices and wearable devices. When the device enters the sleep mode or the standby mode, the PPX-Series can still measure the subtle current changes of the DUT. The PPX eries provides the Test Sequence function, which allows users to arbitrarily define-S output waveforms. The voltage rising or falling time and the voltage maintenance time of each step can be set. For the operation, users can directly edit parameters on the front panel of the PPX -Series, or the CSV file can be edited via computer and imported into the PPX-Series, and the PPX -Series can be remotely edited. In addition, the OCP Delay function of the PPX-Series allows users to flexibly adjust the time to enable the over-current protection according to the characteristics of the DUT to protect the DUT and at the same time to test the current change of the DUT within a certain period of time. Other than voltage, current, and power measurement, the PPX-Series also supports temperature measurement. While collocating with a K Type Thermocouple, the temperature range can be measured from -200°C ~ +1372°C. Supported standard communication interfaces include USB, LAN, RS-232, RS-485 and optional GPIB interface. Model Output Voltage Output Current Output Power * CV, CC Priority Start Function * Four Levels of Current Measurement Resolution (min. 0.1µA)/Two Levels of Voltage MReasurement esolution (min. 0.1mV) * Power Output ON/OFF Delay Function * Adjustable Voltage and Current Slew Rate * Bleeder Circuit Control * Delayed Over-current Protection(OCP Delay) * Sequential Power Output Function * Remote Sensing Function * Data Logger * 10 Sets of Memory Function * Over Voltage Protection, Under Voltage Limit, Over Current Protection, Over Temperature Protection, AC Alarm Function * Supports K Type Thermocouple Temperature Measurement * Interfaces: USB, LAN, RS-232, RS-485, Analog Control; Opt: GPIB * Size: 3U High, in Line with 1/4 Rack Rear Panel Front Panel PROGRAMMABLE HIGH-PRECISION DC POWER SUPPLY

CD (User Manual), Power Cord, Test Lead(GTL-104A for PPX-1005/PPX-2005/PPX- 3603, 1m, 10A)(GTL-105A for PPX-2002/PPX-3601, 1m, 3A)(GTL-204A for PPX- 1005/PPX-2005/PPX-3603<European Type Jack Terminal>, 1m, 10A)(GTL-203A for PPX-2002/PPX-3601/PPX-10H01<European Type Jack Terminal>, 1m, 3A) (GTL-201A, Ground lead for European Type Jack Terminal) PPX-SeriesD1DH PPX-1005(10V/5A/50W) PPX-2002(20V/2A/40W) PPX-2005(20V/5A/100W) PPX-3601(36V/1A/36W) PPX-3603(36V/3A/108W) PPX-10H01(100V/1A/100W) PPX-G Specifications subject to change without notice. *1. Time for output voltage to recover within ±(0.1% + 10mV) of its rated output for a load change from 50% to 100% of its rated output current *2. Measurement frequency bandwidth is 5 Hz to 1 MHz *3. Measurement frequency bandwidth is 10 Hz to 20 MHz ACCESSORIES OPTIONAL ACCESSORIES

ORDERING INFORMATION

GTL-258 GPIB Cable, 2000mm GTL-259 RS-232 Cable with DB9 connector to RJ45 GTL-260 RS-485 Cable with DB9 connector to RJ45 GTL-262 RS-485 Slave cable GTL-246 USB Cable(USB 2.0 Type A-Type B Cable,4P) GTL-205A Temperature probe Adapter(thermal coupling, K-Type), about 1000mm GRA-441-J Rack for PPX Series(JIS) GRA-441-E Rack for PPX Series(EIA) Programmable High-precision DC Power Supply Programmable High-precision DC Power Supply Programmable High-precision DC Power Supply Programmable High-precision DC Power Supply Programmable High-precision DC Power Supply Programmable High-precision DC Power Supply GPIB Interface(factory installed) Nominal nput VoltageI Model Input Frequency Range Output Voltage Output Current Output Power Voltage Range Current Range Measurement Resolution Measurement Accuracy Temperature (K-Type Thermocouple) Over Voltage Protection(OVP) Over Current Protection(OCP) Over Temperature Protection(OTP) LAN USB RS-232/RS-485 Operaing Temperature Storage Temperature Operating Humidity Storage Humidity Dimensions & Weight H L H M L LL Voltage(H) Voltage(L) Current(H) Current(M) Current(L) Current(LL) Voltage(H/L) Temperature Coefficient (TYP.) Current(H/M) Current(L/LL) Temperature Coefficient (TYP.) Range Resolution Accuracy Operation Setting Range Setting Accuracy Operation Setting Range Setting Accuracy Operation Line Regulation Load Regulation Ripple Noise(Arms ) Setting Range (105%) Setting Resolution ℃℃Setting Accuracy (23 ±5 ) Temperature Coefficient (TYP.) DC Output Mode CONSTANT VOLTAGE OPERATION CONSTANT CURRENT OPERATION MEASUREMENT AND DISPLAY TEMPERATURE MEASURED PROTECTION Interface Capabilities OTHER Line Regulation Load Regulation Transient Response Ripple Noise(Vrms /Vpp ) *2 *3 Rise Time Rated load No load Fall Time Rated load No load Setting Range (105%) Setting Resolution Setting Accuracy (23 ±5 )℃℃ Temperature Coefficient (TYP.) Max. Inrush Current Max. Power Consumption *7. Before connecting the power plug to an AC line outlet, make sure the voltage selector switches of the bottom panel in the correct position.It might be damaged the instrument by connecting to the wrong AC line voltage *4. From 10%~90% of rated output voltage, with rated resistive load *5. From 90%~10% of rated output voltage, with rated resistive load *6. Temperature coefficient: after a 30 minute warm-up PPX-3601 PPX-3603 PPX-10H01PPX-1005 PPX-2002 PPX-2005 Turns the output off, displays OVP and lights ALARM (5% to 110% of the rated output voltage) ±(1% of rating) Turns the output off, displays OCP and lights ALARM (5% to 110% of the rated output current) ±(1% of rating) Turns the output off, displays OTP and lights ALARM MAC Address, DNS IP Address, User Password, Gateway IP Address, Instrument IP Address, Subnet Mask Type A: Host, Type B: Slave, Speed: 1.1/2.0, USB-CDC Complies with the EIA-RS-232/RS-485 specifications (excluding the connector) °°0 C ~ 40 C °°-20 C ~ 70 C 20% ~ 80% RH; No condensation 20% ~ 85% RH; No condensation 107(W) × 124(H) × 313(D) mm (not including protrusions); Approx. 5.5kg 100Vac / 120Vac / 220Vac / 240Vac(±10%), 50Hz / 60Hz, single phase 47Hz ~ 63Hz 10.000V 5.0000A 50W 20.000V 2.0000A 40W 20.000V 5.0000A 100W 36.000V 1.0000A 36W 36.000V 3.0000A 108W 100.00V 1.0000A 100W 2mA 1mA 2mA 400 A /c109 1mA 1mA ±(0.05% of setting+1.0mA) 200 ppm/℃ 200 ppm/℃ 200 ppm/℃ 200 ppm/℃ 200 ppm/℃ 200 ppm/℃ 10.000V 1.0000V 5.0000A 500.00mA 50.000mA 5.0000mA 1mV 0.1mV 0.1mA 0.01mA 0.001mA 0.0001mA ±(0.03% of rdg + 2mV) 100 ppm/℃ ±(0.05% of rdg + 2.5mA) ±(0.1% of rdg + 40 A)/c109 200 ppm/℃ 20.000V 2.0000V 2.0000A 200.00mA 20.000mA 2.0000mA 1mV 0.1mV 0.1mA 0.01mA 0.001mA 0.0001mA ±(0.03% of rdg + 4mV) 100 ppm/℃ ±(0.05% of rdg + 1.0mA) ±(0.1% of rdg + 24 A)/c109 200 ppm/℃ 20.000V 2.0000V 5.0000A 500.00mA 50.000mA 5.0000mA 1mV 0.1mV 0.1mA 0.01mA 0.001mA 0.0001mA ±(0.03% of rdg + 5mV) 100 ppm/℃ ±(0.05% of rdg + 2.5mA) ±(0.1% of rdg + 40 A)/c109 200 ppm/℃ 36.000V 3.6000V 1.0000A 100.00mA 10.000mA 1.0000mA 1mV 0.1mV 0.1mA 0.01mA 0.001mA 0.0001mA ±(0.03% of rdg + 6mV) 100 ppm/℃ ±(0.05% of rdg + 0.4mA) ±(0.1% of rdg + 16 A)/c109 200 ppm/℃ 36.000V 3.6000V 3.0000A 300.00mA 30.000mA 3.0000mA 1mV 0.1mV 0.1mA 0.01mA 0.001mA 0.0001mA ±(0.03% of rdg + 8mV) 100 ppm/℃ ±(0.05% of rdg + 1.2mA) ±(0.1% of rdg + 28 A)/c109 200 ppm/℃ 100.00V 10.000V 1.0000A 100.00mA 10.000mA 1.0000mA 10mV 1mV 0.1mA 0.01mA 0.001mA 0.0001mA ±(0.03% of rdg + 15mV) 100 ppm/℃ ±(0.05% of rdg + 1.0mA) ±(0.1% of rdg + 24 A)/c109 200 ppm/℃ ±(0.01% of setting+7mV) ±(0.01% of setting+7mV) <100 s/c109 1.2mVrms/<15mVpp 100ms 100ms 50ms 250ms 0V ~ 105.0V 2mV ±(0.03% of setting+20mV) 100 ppm/℃ ±(0.01% of setting+3mV) ±(0.01% of setting+4mV) <50 s/c109 0.8mVrms/<10mVpp 50ms 50ms 20ms 150ms 0V ~ 37.8V 1mV ±(0.03% of setting+8mV) 100 ppm/℃ ±(0.01% of setting+3mV) ±(0.01% of setting+3mV) <50 s/c109 0.8mVrms/<10mVpp 50ms 50ms 20ms 150ms 0V ~ 37.8V 1mV ±(0.03% of setting+8mV) 100 ppm/℃ ±(0.01% of setting+1mV) ±(0.01% of setting+3mV) <50 s/c109 0.5mVrms/<8mVpp 50ms 50ms 20ms 150ms 0V ~ 21.0V 0.5mV ±(0.03% of setting+5mV) 100 ppm/℃ ±(0.01% of setting+1mV) ±(0.01% of setting+2mV) <50 s/c109 0.5mVrms/<8mVpp 50ms 50ms 20ms 150ms 0V ~ 21.0V 0.5mV ±(0.03% of setting+5mV) 100 ppm/℃ ±(0.01% of setting+1mV) ±(0.01% of setting+2mV) <50 s/c109 0.35mVrms/<6mVpp 20ms 20ms 10ms 100ms 0V ~ 10.5V 0.2mV ±(0.03% of setting+3mV) 100 ppm/℃ -200 ~+1372℃℃ 0.25℃ ±(0.5% + 2 )℃ Remote Sensing Compensation Voltage(single line) NOTE: SPECIFICATIONS