ø8·10·12·16 AP Series Miniature Pilot Lights AC Adapter/DC-DC Converter (Option) Unit AC Adapter DC-DC Converter Applicable Unit AP6M and AP2M (6V rating only) Rated Voltage 100/110V AC, 200/220V AC 50/60 Hz 110V DC Voltage Range 100/110V AC±10% 200/220V AC±10% 90 to 140V Power Consumption 1.6 VA maximum 1W maximum Insulation Voltage 250V AC 140V DC Insulation Resistance Between live and dead parts:
100 MΩ minimum (500V DC megger)
Between live and dead parts: 2000V, 1 minute Between I/O terminals: 2000V AC/, 1 minute Between I/O terminals: 1500V AC, 1 minute Terminal Style M3 screw Weight (approx.) 38g 20g Flasher Unit (Option) Applicable Unit AP6M (12V and 24V DC rating only) Rated Voltage 12/24V DC compatible Voltage Range 12/24V DC±10% Flashing Period Adjustable between approximately 30 to 600 cycles per minute (period 0.1 to 2 sec) Current Draw 4 mA (OFF) to 6 mA (ON) Terminal Style M3 screw Weight (approx.) 13.5g Super Bright LEDs with built-in current-limiting resistor
- Space saving miniature style.
- Illumination colors: amber, blue, green, pure white, red, and yellow (blue and pure white available for AP8M and AP1M only)
- Marking is available on flat lens units. (except AP8M series)
- See website for details on approvals and standards. Pilot Light Input Type Full voltage Model AP2M / AP6M AP8M / AP1M Rated Voltage 6V AC/DC 12V AC/DC 24V AC/DC 5V DC 12V AC/DC 24V AC/DC Voltage Range 6V AC/DC±5% 12V AC/DC±10% 24V AC/DC±10% 5V DC±5% 12V AC/DC±10% 24V AC/DC±10% Rated Current 5mA 4mA Illumination Color Code A (amber), G (green), PW (pure white), R (red), Y (yellow) A (amber), G (green), PW (pure white), R (red), S (blue), Y (yellow) Operating Temperature –20 to +55°C (no freezing) Storage Temperature –30 to +55°C (no freezing) Operating Humidity 45 to 85% RH (no condensation) Insulation Resistance Between live and dead parts: 100 MΩ minimum (500V DC megger) Dielectric Strength Between live and dead parts: 1000V, 1 minute Solder Terminal Soldering 350°C maximum (3 sec) Applicable Wire ø1.0 or 0.75 mm2 maximum (20 to 16 AWG) Degree of Protection AP6M, AP2M, AP1M: IP65 AP8M: IP40 (according to IEC 60529) AP2M AC adapter unit AP6M AC adapter unit Flasher unit ∗) AP8M and AP1M only (∗) (∗)
ø16 AP Series Miniature Pilot Lights Shape Operating Voltage Part No. Ordering No. Package Quantity Lens Color Code Dome 6V DC AP6M266➁ AP6M266➁ 1 Specify a lens color code in place of ➁ in the Part No. A: amber G: green PW: pure white R: red Y: yellow AP6M266➁PN10 10 12V DC AP6M211➁ AP6M211➁ 1 AP6M211➁PN10 10 24V DC AP6M222➁ AP6M222➁ 1 AP6M222➁PN10 10 Flat (marking) 6V DC AP6M166➁ AP6M166➁ 1 AP6M166➁PN10 10 12V DC AP6M111➁ AP6M111➁ 1 AP6M111➁PN10 10 24V DC AP6M122➁ AP6M122➁ 1 AP6M122➁PN10 10
- Degree of protection: IP65 (IEC 60529)
- The LED cannot be replaced. Dimensions GasketDome Flat ø15.6 ø18 5.5 21.5 29.5 Panel Thickness 0.8 to 6 1.5 Width 2.8, Thickness 0.4 Hole 2-ø1.2 2.2 ø15.6 ø18 5.5 13.5 9.5 M3 ScrewAC Adapter, DC-DC Converter, or Flasher Unit X1X2 58.7 18 1.3 Positive Terminal Negative Terminal Terminal Cover: AP-VL3 TOP Terminal Arrangement (Bottom View) Marking Plate Panel Cut-out / Mounting Hole Layout ø12.96 Terminal cover is not supplied. When using terminal covers, order AP-VL3 terminal covers. Engraving depth: 0.5 mm maximum Marking plate material: White acrylic All dimensions in mm. Note: (18) is the minimum mounting hole layout without AC adapter or flasher unit. With AC Adapter, DC-DC Converter, Flasher Unit ø16.2 +0.2 (18) +0.20 ø16.2 AC Adapter, DC-DC Converter, Flasher Unit Unit Operating Voltage Part No. Applicable Pilot Light Package Quantity AC Adapter 100/110V AC AP6-016D AP6M266➁ (dome: 6V DC) AP6M166➁ (flat: 6V DC) 200/220V AC AP6-026D DC-DC Converter 110V DC (90 to 140V DC) AP6-016DD Flasher Unit 12/24V DC UZ6-F10 AP6M211➁ (dome: 12V DC) AP6M222➁ (dome: 24V DC) AP6M111➁ (flat: 12V DC) AP6M122➁ (flat: 24V DC) Positive Terminal Negative Terminal + – AP6M Series (ø16)
ø12 AP Series Miniature Pilot Lights AC Adapter, DC-DC Converter Unit Operating Voltage Part No. Applicable Pilot Light Package Quantity AC Adapter 100/110V AC AP2-016D AP6M266➁ (dome: 6V DC) AP6M166➁ (flat: 6V DC) 1200/220V AC AP2-026D DC-DC Converter 110V DC (90 to 140V DC) AP2-016DD Dimensions 1.52.2 ø12 ø14 5.5 21.5 29.5 ø12 ø14 5.5 11.5 9.5 Panel Thickness 0.8 to 6 Gasket Dome Flat Width 2.8×0.4t X1X2 58.7 Terminal Cover: AP-VL3
1.3 Negative Terminal
AC Adapter/DC-DC Converter Terminal cover is not supplied. When using terminal covers, order AP-VL3 terminal covers. With AC Adapter or DC-DC Converter Panel Cut-out / Mounting Hole LayoutTerminal Arrangement (Bottom View) Marking Plate 5.5 5.5 ø9.4 Positive Terminal Negative Terminal + – All dimensions in mm. Engraving depth: 0.5 mm maximum Marking plate material: White acrylic ø12.2 +0.2 (15) (15) +0.2 ø12.2 Note: (15) is the minimum mounting hole layout without AC adapter or flasher unit. Shape Operating Voltage Part No. Ordering No. Package Quantity Lens Color Code Dome 6V DC ±5% AP2M266➁ AP2M266➁ 1 Specify a lens color code in place of ➁ in the Part No. A: amber G: green PW: pure white R: red Y: yellow AP2M266➁PN10 10 12V DC ±10% AP2M211➁ AP2M211➁ 1 AP2M211➁PN10 10 24V DC ±10% AP2M222➁ AP2M222➁ 1 AP2M222➁PN10 10 Flat (marking) 6V DC ±5% AP2M166➁ AP2M166➁ 1 AP2M166➁PN10 10 12V DC ±10% AP2M111➁ AP2M111➁ 1 AP2M111➁PN10 10 24V DC ±10% AP2M122➁ AP2M122➁ 1 AP2M122➁PN10 10
- Degree of protection: IP65 (IEC 60529)
- The LED cannot be replaced. AP2M Series (ø12)
ø10 AP Series Miniature Pilot Lights Dimensions 1.52.2 5.5 21.5 8 29.5 ø10 ø12 ø12 ø10 5.5 9.5 2.8 Panel Thickness 0.8 to 6 Dome Gasket Flat Marking Plate ø7.7 6.1 6.1 ø7.7 Terminal Arrangement (Bottom View) Projection Positive Terminal Negative Terminal Shape Operating Voltage Part No. Ordering No. Package Quantity Lens Color Code Dome 5V DC ±5% AP1M255➁ AP1M255➁ 1 Specify a lens color code in place of ➁ in the Part No. A: amber G: green PW: pure white R: red S: blue Y: yellow AP1M255➁PN10 10 12V AC/DC ±10% AP1M211➁ AP1M211➁ 1 AP1M211➁PN10 10 24V AC/DC ±10% AP1M222➁ AP1M222➁ 1 AP1M222➁PN10 10 Flat (marking) 5V DC ±5% AP1M155➁ AP1M155➁ 1 AP1M155➁PN10 10 12V AC/DC ±10% AP1M111➁ AP1M111➁ 1 AP1M111➁PN10 10 24V AC/DC ±10% AP1M122➁ AP1M122➁ 1 AP1M122➁PN10 10
- Degree of protection: IP65 (IEC 60529)
- The LED cannot be replaced.
- Separate transformer (TWR512, TWR522, TWR542) can be used for 24V AC/DC pilot lights. Engraving depth: 0.5 mm maximum Marking plate material: White acrylic All dimensions in mm. Panel Cut-out / Mounting Hole Layout ø10.1 +0.2 +0.2 ø10.1 AP1M Series (ø10)
ø8 AP Series Miniature Pilot Lights Dimensions Panel Cut-out / Mounting Hole Layout Terminal Arrangement (Bottom View) Positive Terminal Negative Terminal Projection All dimensions in mm. 1.52.2 5.5 21.58 29.5 5.5 9.5 ø9.8 8.5 ø9.8 3 2.8 Panel Thickness 0.8 to 6 Gasket Dome Flat Width 2.8, Thickness 0.4 Hole 2-ø1.2 Shape Operating Voltage Part No. Ordering No. Package Quantity Lens Color Code Dome 5V DC ±5% AP8M255➁ AP8M255➁ 1 Specify a lens color code in place of ➁ in the Part No. A: amber G: green PW: pure white R: red S: blue Y: yellow AP8M255➁PN10 10 12V AC/DC ±10% AP8M211➁ AP8M211➁ 1 AP8M211➁PN10 10 24V AC/DC ±10% AP8M222➁ AP8M222➁ 1 AP8M222➁PN10 10 Flat 5V DC ±5% AP8M155➁ AP8M155➁ 1 AP8M155➁PN10 10 12V AC/DC ±10% AP8M111➁ AP8M111➁ 1 AP8M111➁PN10 10 24V AC/DC ±10% AP8M122➁ AP8M122➁ 1 AP8M122➁PN10 10
- The lens or LED cannot be removed or replaced.
- Degree of protection: IP40 (IEC 60529)
- Separate transformer (TWR512, TWR522, TWR542) can be used for 24V AC/DC pilot lights. ø8.1 +0.2 +0.20 ø8.1 AP8M Series (ø8)
AP Series Miniature Pilot Lights Shape For Material Part No. Ordering No. Package Quantity Remarks Locking Ring Wrench ø16 Metal (nickel-plated brass) MT-001 MT-001 1 • Used to tighten the locking ring when installing an AP unit onto an panel.
- Tighten the locking ring using a recom- mended tightening torque.ø12 MT-002 MT-002 1 ø10 MT-003 MT-003 1 ø8 MT-004 MT-004 1 Stainless steel MT-100 MT-100 1
- Used to remove the AC adapter, DC-DC converter, or flasher unit. Mounting Hole Plug ø16 Metal (diecast) Locking ring (polyacetal) AL-BM6 AL-BM6 1
- Degree of protection: IP65 Nitryl rubber (black) AL-B6 AL-B6PN05 5
- Degree of protection: IP65 ø12 Nitryl rubber (black) AL-B2 AL-B2PN05 5
- Degree of protection: IP65 ø10 Nitryl rubber (black) AL-B1 AL-B1PN05 5
- Degree of protection: IP65 ø8 Nitryl rubber (black) AL-B8 AL-B8PN05 5
- Degree of protection: IP65 Replacement Parts for AP6M/AP2M/AP1M Shape For Part No. Ordering No. Package Quantity Lens Color Code Lens AP6M Dome lens AP6M-L2➁ AP6M-L2➁PN05 5 A (amber), G (green), R (red), W (white), Y (yellow) (Note 1) Flat lens AP6M-L1➁ AP6M-L1➁PN05 5 A (amber), C (clear), G (green), R (red), Y (yellow) (Note 2) AP2M Dome lens AP2M-L2➁ AP2M-L2➁PN05 5 A (amber), G (green), R (red), W (white), Y (yellow) (Note 1) Flat lens AP2M-L1➁ AP2M-L1➁PN05 5 A (amber), C (clear), G (green), R (red), Y (yellow) (Note 2) AP1M Dome lens AP1M-L2➁ AP1M-L2➁PN05 5 A (amber), G (green), R (red), S (blue), W (white), Y (yellow) (Note 1) Flat lens AP1M-L1➁ AP1M-L1➁PN05 5 A (amber), C (clear), G (green), R (red), S (blue), Y (yellow) (Note 2) Marking Plate AP6M Flat lens AP6M-P1W AP6M-P1WPN05 5 WhiteAP2M AP2M-P1W AP2M-P1WPN05 5 AP1M AP1M-PN1W AP1M-PN1WPN05 5 Diffusion Plate AP1M Dome lens AP1M-PN2W AP1M-PN2WPN05 5 White Terminal Cover AP6M AP2M AC adapter DC-DC converter Flasher unit AP-VL3 AP-VL3 1 Specify a lens color code in place of ➁ in the Ordering No. Note 1: On the dome lens, use a white (W) lens for pure white P(W) illumination. Note 2: On the flat lens, use a clear (C) lens for pure white (PW) illumination. Part No. Size MT-001 MT-002 MT-003 MT-004 ø18 ø14 ø12 ø9.5 Removal Tool 2 6 ø16.5 ø18 ø17.8 2.5 12.0 1.8 4.2 ø9 4.8 ø14 4.4 2 ø12 317.2 20.2 ø5.5 11.3 4 to 5 Accessories
AP Series Miniature Pilot Lights
- Turn off power to the AP series pilot lights before installation, re- moval, wiring, maintenance, and inspection. Failure to turn power off may cause electrical shocks or fire hazard.
- For wiring, use wires of proper size to meet the voltage and cur- rent requirements. Improper wiring may cause overheating and create a fire hazard. Tighten the M3 terminal screws to a torque of 0.6 to 1.0 N·m. Failure to tighten terminal screws may cause overheating and fire. Panel Mounting When mounting the AP series pilot lights on a panel, use the optional locking ring wrench. Do not use pliers. Excessive tightening will damage the locking ring. Unit Tightening Torque AP6M 0.88 N·m AP2M 0.78 N·m AP1M 0.29 N·m AP8M 0.29 N·m Installing the AC Adapter, DC-DC Converter, and Flasher Unit 1. Make sure that the voltage rating and terminal style of the AP series pilot lights are applicable to the AC adapter, DC-DC Converter, and flasher units. 2. Install the pilot light into a panel cut-out before mounting an AC adapter, DC-DC Converter, or flasher unit. Note that the pilot light cannot be installed in a panel cut-out with an AC adapter, DC-DC Converter, or flasher unit mounted. 3. When installing an AC adapter, DC-DC Converter, or flasher unit, make sure that the TOP marking is on the same side as the TOP making of the pilot light. AC adapter, DC-DC Convert- er, and flasher unit are snapped on to the back of the pilot light. 4. To remove the AC adapter, DC-DC Converter, or flasher unit, insert the tip of the removal tool into the joint hook and pull towards you as shown in the photo below. 5. When using an AC adapter, DC-DC Converter, or flasher unit where the units are subjected to noise, connect a noise su- pressor across terminals X1 and X2 as shown in the diagram below. Wiring 1. Note the positive and negative polarities when wiring DC types. 2. All DC type AP series pilot lights contain a current limiting resistor, eliminating the need for external resistors. 3. Solder the terminal at 350°C within 3 seconds using a 60W soldering iron. SnAgCu type lead-free solder is recommended. When soldering, do not touch the pilot light housing with the soldering iron. Also ensure that no tensile force is applied to the terminal. Do not bend the terminal or apply excessive force to the terminal. Use a non-corrosive rosin flux. DC-DC Converter DC-DC converters employ an electronic oscillating circuit. Oscillating sounds may be heard depending on operating conditions, but will not affect performance characteristics. Marking AP6M, AP2M, and AP1M round flat lenses contain a white marking plate inside the lens. (AP8M lens cannot be removed.) Flasher Unit Pierce the round mark on the nameplate on top of the flasher unit with a flat screwdriver and adjust the variable resistor inside.Turn clockwise to lengthen the flashing period. TOP TOP TOP TOP TOP TOP TOP TOP X2 Negative Terminal X2 Negative Terminal Positive Terminal Positive Terminal Negative Terminal Negative Terminal X1 Positive Terminal X1 Positive Terminal Nameplate Nameplate AP2 Series AP6 Series Note: Do not apply excessive force to terminals X1 and X2 during wiring. Noise Suppressor TOP TOP TOP TOP X2 Negative Terminal X1 Positive Terminal Positive Terminal Negative Terminal Nameplate Note: Do not apply excessive force to terminals X1 and X2 during wiring. Safety Precautions Instructions EP5041A AP December 2022
- Notes on contents of Catalogs (1) Rated values, performance values, and specification values of IDEC products listed in this Catalog are values acquired under respective conditions in independent testing, and do not guarantee values gained in combined conditions. Also, durability varies depending on the usage environment and usage conditions. (2) Reference data and reference values listed in Catalogs are for reference purposes only, and do not guarantee that the product will always operate appropriately in that range. (3) The specifications / appearance and accessories of IDEC products listed in Catalogs are subject to change or termination of sales without notice, for improvement or other reasons. (4) The content of Catalogs is subject to change without notice. 2. Note on applications (1) If using IDEC products in combination with other products, confirm the applicable laws / regulations and standards. Also, confirm that IDEC products are compatible with your systems, machines, devices, and the like by using under the actual conditions. IDEC shall bear no liability whatsoever regarding the compatibility with IDEC products. (2) The usage examples and application examples listed in Catalogs are for reference purposes only. Therefore, when introducing a product, confirm the performance and safety of the instruments, devices, and the like before use. Furthermore, regarding these examples, IDEC does not grant license to use IDEC products to you, and IDEC offers no warranties regarding the ownership of intellectual property rights or non-infringement upon the intellectual property rights of third parties. (3) When using IDEC products, be cautious when implementing the following. i. Use of IDEC products with sufficient allowance for rating and performance ii. Safety design, including redundant design and malfunction prevention design that prevents other danger and damage even in the event that an IDEC product fails iii. Wiring and installation that ensures the IDEC product used in your system, machine, device, or the like can perform and function according to its specifications (4) Continuing to use an IDEC product even after the performance has deteriorated can result in abnormal heat, smoke, fires, and the like due to insulation deterioration or the like. Perform periodic maintenance for IDEC products and the systems, machines, devices, and the like in which they are used. (5) IDEC products are developed and manufactured as general-purpose products for general industrial products. They are not intended for use in the following applications, and in the event that you use an IDEC product for these applications, unless otherwise agreed upon between you and IDEC, IDEC shall provide no guarantees whatsoever regarding IDEC products. i. Use in applications that require a high degree of safety, including nuclear power control equipment, transportation equipment (railroads / airplanes / ships / vehicles / vehicle instruments, etc.), equipment for use in outer space, elevating equipment, medical instruments, safety devices, or any other equipment, instruments, or the like that could endanger life or human health ii. Use in applications that require a high degree of reliability, such as provision systems for gas / waterworks / electricity, etc., systems that operate continuously for 24 hours, and settlement systems iii. Use in applications where the product may be handled or used deviating from the specifications or conditions / environment listed in the Catalogs, such as equipment used outdoors or applications in environments subject to chemical pollution or electromagnetic interference If you would like to use IDEC products in the above applications, be sure to consult with an IDEC sales representative. 3. Inspections We ask that you implement inspections for IDEC products you purchase without delay, as well as thoroughly keep in mind management/maintenance regarding handling of the product before and during the inspection. 4. Warranty (1) Warranty period The warranty period for IDEC products shall be one (1) year after purchase or delivery to the specified location. However, this shall not apply in cases where there is a different specification in the Catalogs or there is another agreement in place between you and IDEC. (2) Warranty scope Should a failure occur in an IDEC product during the above warranty period for reasons attributable to IDEC, then IDEC shall replace or repair that product, free of charge, at the purchase location / delivery location of the product, or an IDEC service base. However, failures caused by the following reasons shall be deemed outside the scope of this warranty. i. The product was handled or used deviating from the conditions / environment listed in the Catalogs ii. The failure was caused by reasons other than an IDEC product iii. Modification or repair was performed by a party other than IDEC iv. The failure was caused by a software program of a party other than IDEC v. The product was used outside of its original purpose vi. Replacement of maintenance parts, installation of accessories, or the like was not performed properly in accordance with the user’s manual and Catalogs vii. The failure could not have been predicted with the scientific and technical standards at the time when the product was shipped from IDEC viii. The failure was due to other causes not attributable to IDEC (including cases of force majeure such as natural disasters and other disasters) Furthermore, the warranty described here refers to a warranty on the IDEC product as a unit, and damages induced by the failure of an IDEC product are excluded from this warranty. 5. Limitation of liability The warranty listed in this Agreement is the full and complete warranty for IDEC products, and IDEC shall bear no liability whatsoever regarding special damages, indirect damages, incidental damages, or passive damages that occurred due to an IDEC product. 6. Service scope The prices of IDEC products do not include the cost of services, such as dispatching technicians. Therefore, separate fees are required in the following cases. (1) Instructions for installation / adjustment and accompaniment at test operation (including creating application software and testing operation, etc.) (2) Maintenance inspections, adjustments, and repairs (3) Technical instructions and technical training (4) Product tests or inspections specified by you The above content assumes transactions and usage within your region. Please consult with an IDEC sales representative regarding transactions and usage outside of your region. Also, IDEC provides no guarantees whatsoever regarding IDEC products sold outside your region. Ordering Terms and Conditions Thank you for using IDEC Products. By purchasing products listed in our catalogs, datasheets, and the like (hereinafter referred to as “Catalogs”) you agree to be bound by these terms and conditions. Please read and agree to the terms and conditions before placing your order. Speci/f_ications and other descriptions in this brochure are subject to change without notice. 2022 IDEC Corporation, All Rights Reserved. USA IDEC Corporation EMEA APEM SAS China IDEC (Shanghai) Corporation IDEC Izumi (H.K.) Co., Ltd. Taiwan IDEC Taiwan Corporation Singapore IDEC Izumi Asia Pte. Ltd. Thailand IDEC Asia (Thailand) Co., Ltd. India IDEC Controls India Private Ltd. Japan IDEC Corporation Head Office 6-64, Nishi-Miyahara-2-Chome, Yodogawa-ku, Osaka 532-0004, Japan www.idec.com