Issue 2 - July 2006 1 www.zetex.com © Zetex Semiconductors plc 2006 AN44 A high power LED driver for low voltage halogen replacement Introduction LED lighting is becoming more popular as a re placement technology for Halogen low voltage lighting, primarily because of the low efficiency, reliability and lifetime issues associated with Halogen bulbs. Discussed below is a novel approach for drivi ng high power LED's as a replacement for low voltage halogen lighting systems. A typical schematic diagram is shown in Figure 1. Figure 1 Schematic diagram Operation Please refer to the typical schematic diagram in Figure 1. On period, T ON The ZXSC300 turns on Q1 until it senses 19mV (nominal) on the ISENSE pin. The current in Q1 to reach this threshold is therefore 19mV/R1, called IPEAK. With Q1 on, the current is drawn from the battery and passes through C1 and LED in parallel. Assume the LED drops a forward voltage VF. The rest of the battery voltage will be dropped across L1 and this voltage, called V(L1) will ramp up the current in L1 at a rate di/dt = V(L1)/L1, di/dt in Amps/sec, V(L1) in volts and L1 in Henries. The voltage drop in Q1 and R1 should be negligible, since Q1 should have a low R DS(on) and R1 always drops less than 19mV, as this is the turn-off threshold for Q1. VIN = VF + V(L1) TON = IPEAK x L1/ V(L1)
www.zetex.com 2 Issue 2 - July 2006 © Zetex Semiconductors plc 2006 So TON can be calculated, as the voltage across L1 is obtained by subtracting the forward LED voltage drop from VIN. Therefore, if L1 is smaller, T ON will be smaller for the same peak current IPEAK and the same battery voltage V IN. Note that, while the inductor current is ramping up to IPEAK, the current is flowing through the LED and so the average current in the LED is the sum of the ramps during the TON ramping up period and the TOFF ramping down period. Off period, TOFF The TOFF of ZXSC300 and ZXSC310 is fixed internally at nominally 1.7µs. Note that, if relying on this for current ramp calculations, the limits are 1.2µs min., 3.2µs max. In order to minimize the conductive loss and switching loss, TON should not be much smaller than TOFF. Very high switching frequencies cause high dv/dt and it is recommended that the ZXSC300 and 310 are operated only up to 200 kHz. Given the fixed T OFF of 1.7µs, this gives a TON of (5µs - 1.7µs) = 3.3µs minimum. However, this is not an absolute limitation and these devices have been operated at 2 or 3 times this frequency, but conversion efficiency can suffer under these conditions. During T OFF, the energy stored in the inductor will be transferred to the LED, with some loss in the Schottky diode. The energy stored in the inductor is: ½ x L x IPEAK2 [Joules] Continuous and discontinuous modes (and average LED current) If T OFF is exactly the time required for the current to reach zero, the average current in the LED will be IPEAK/2. In practice, the current might reach zero before TOFF is complete and the average current will be less because part of the cycle is spent with zero LED current. This is called the ‘discontinuous’ operation mode and is shown in Figure 2. Figure 2
Issue 2 - July 2006 3 www.zetex.com © Zetex Semiconductors plc 2006 For continuous mode If the current does not reach zero after 1.7µs, but instead falls to a value of I MIN, then the device is said to be in ‘continuous’ mode. The LED current will ramp up and down between IMIN and IPEAK (probably at different di/dt rates) and the average LED current will therefore be the average of I PEAK and IMIN, as shown in Figure 3. Figure 3 Design example (Refer to Figure 1 and Table 1) Input = VIN = 12V LED forward drop = VLED = 9.6V VIN = VLED+VL Therefore VL = (12 - 9.6) = 2.4 The peak current = VSENSE / R1 (R1 is RSENSE) = 24mV/50mR = 480mA TON = IPEAK x L1/V(L1) These equations make the approximation that the LED forward drop is constant throughout the current ramp. In fact it will increase with curre nt, but they still enable design calculations to be made within the tolerances of the components us ed in a practical circui t. Also, the difference between VIN and VLED is small compared to either of them, so the 6.2µs ramp time will be fairly dependent on these voltages. Note that, for an LED drop of 9.6V and a Schottky drop of 300mV, the time to ramp down from 680mA to zero would be: TON 680mAx22 µH TDIS 680mAx22 µH
www.zetex.com 4 Issue 2 - July 2006 © Zetex Semiconductors plc 2006 As the TOFF period is nominally 1.7µs, the current should have time to reach zero. However, 1.5µs is rather close to 1.7µs and it is possible that, over component tolerances, the coil current will not reach zero, but this is not a big issue as the remaining current will be small. Note that, because of the peak current measurement and switch-off, it is not possible to get the dangerous ‘inductor staircasing’ which occurs in converters with fixed T ON times. The current can never exceed IPEAK, so even if it starts from a finite value (i.e. continuous mode) it will not exceed the I PEAK. The LED current will therefore be approximately the average of 680mA and zero = 340mA (it will not be exactly the average, because there is a 200ns period at zero current, but this is small compared with the I PEAK and component tolerances). Ref Value Part number Manufacturer Contact details Comments U1 ZXSC310E5 Zetex www.zetex.com LED Driver in SOT23-5 Q1 ZXMN6A07F Zetex www.zetex.com N-channel MOSFET in SOT23 D1 1A / 40V ZHCS1000 Zetex www.zetex.com 1A Schottky diode in SOT23 D2 6V8 Generic Generic 6V8 Zener diode L1 22 /H9262H DO3316P-223 Coilcraft www.coilcraft.com R1 50m /H9024Generic Generic 0805 size R2 1k2 /H9024Generic Generic 0805 size C1 100 /H9262F/25V Generic Generic C2 1 /H9262F/10V Generic Generic C3 2.2 /H9262F/25V Generic Generic Table 1 Bill of materials
www.zetex.com 6 Issue 2 - July 2006 © Zetex Semiconductors plc 2006 For international sales offices visit www.zetex.com/offices Zetex products are distributed worldwide. For details, see www.zetex.com/salesnetwork This publication is issued to provide outline information only whic h (unless agreed by the company in writing) may not be used, applied or reproduced for any purpose or form part of any order or contact or be regarded as a representation relating to the products or services concerned. The company reserves the right to alter without notice the specification, design, price or conditions of supply of any product or service. Europe Zetex GmbH Streitfeldstraße 19 D-81673 München Germany Telefon: (49) 89 45 49 49 0 Fax: (49) 89 45 49 49 49 europe.sales@zetex.com Americas Zetex Inc
700 Veterans Memorial Highway
Hauppauge, NY 11788 USA Telephone: (1) 631 360 2222 Fax: (1) 631 360 8222 usa.sales@zetex.com Asia Pacific Zetex (Asia Ltd) 3701-04 Metroplaza Tower 1 Hing Fong Road, Kwai Fong Hong Kong Telephone: (852) 26100 611 Fax: (852) 24250 494 asia.sales@zetex.com Corporate Headquarters Zetex Semiconductors plc Zetex Technology Park, Chadderton Oldham, OL9 9LL United Kingdom Telephone: (44) 161 622 4444 Fax: (44) 161 622 4446 hq@zetex.com Useful formulae for calculations The input power from the battery during TON (assuming discontinuous operation mode) is VIN * IPEAK/2. The average input current from the battery is therefore this current multiplied by the ratio of TON to the total cycle time: It can be seen from this how the average battery current will increase at lower VIN as TON becomes larger compared to the fixed 1.7µs T OFF. This is logical, as the fixed (approximately) LED power will require more battery current at lower battery voltage to draw the same power. The energy which is stored in the inductor equa ls the energy which is transferred from the inductor to the LED (assuming discontinuous operation) is: ½ * L1 * IPEAK 2 [Joules] Therefore, when the input and the output voltage difference are greater, the LED will have more energy which will be transferred from the inductor to the LED rather than be directly obtained from the battery. If the inductor size L1 and peak current I PEAK can be calculated such that the current just reaches zero in 1.7µs, then the power in the LED will not be too dependent on battery volts, since the average current in the LED will always be approximately IPEAK/2. As the battery voltage increases, the T ON necessary to reach I PEAK will decrease, but the LED power will be substantially constant and it will just draw a battery current ramping from zero to I PEAK during TON. At higher battery voltages, TON will have a lower proportional of the total cycle time, so that the average battery current at higher battery voltage will be less, such that power (and efficiency) is conserved. The forward voltage which is across the Schottky diode detracts from the efficiency. For example, assuming V F of the LED is 6V and VF of the Schottky is 0.3V, the efficiency loss of energy which is transferred from the inductor is 5%, i.e. the ratio of the Schottky forward drop to the LED forward drop. The Schottky is not in circuit during the T ON period and therefore does not cause a loss, so the overall percentage loss will depend on the ratio of the TON and TOFF periods. For low battery voltages where TON is a large proportion of the cycle, the Schottky loss will not be significant. The Schottky loss will also be less significant at higher LED voltages (more LED's in series) as Schottky drop becomes a lower percentage of the total voltage. IPEAK TON TON IPEAK L1×