90 Watts
- CEC2008 & EISA2007 Compliant ≥12V
- Worldwide Medical Approvals
- Small Size/High Power Density
- Class I and Class II Versions
- Operating Temperature up to +60 °C
- High Efficiency
- Locking Output Connector≥15 V AMM90 Series Input Input Voltage • 90-264 VAC Input Frequency • 47-63 Hz Input Current • 1.2 A rms at 115 VAC,
0.6 A rms at 230 VAC
Inrush Current • 60 A at 115 VAC, 120 A at 230 VAC, cold start +25 °C Power Factor • 0.98 typical Earth Leakage Current• 90 µA max at 115 VAC/60 Hz, (Class I Versions) 150 µA max at 230 VAC/50 Hz Input Protection • Internal 2.5 A fuse in live & neutral lines Output Output Voltage • 5 to 48 VDC Output Voltage Trim • Not user-adjustable Initial Set Accuracy• ±2 % Minimum Load • No minimum load required Start Up Delay • 2 s max at 115 VAC Start Up Rise Time • <80 ms at 115 VAC Hold Up Time • 15 ms minimum at full load & 115 VAC Line Regulation • 0.5% maximum Load Regulation • See table Transient Response • 4% max. deviation, recovery to within 1% in 500 µs for a 25% load change Ripple & Noise • 2% max pk-pk (see note 1) Overvoltage Protection• 112-140% Vnom, recycle input to reset Overtemperature • Unit shuts down, auto recovery Protection Overload Protection • 110-200%, auto recovery Short Circuit Protection• Trip and restart (Hiccup mode) Temperature • 0.04%/°C Coefficient xppower.com General Efficiency • 78% min for 5 V, 6 V & 9 V models 85% minimum for all others Isolation • 4000 VAC Input to Output
1500 VAC Input to Ground (Class I only)
500 VAC Output to Ground (Class I only)
Switching Frequency • 50-110 kHz variable Power Density • 3.4 W/In3 MTBF • 150 kHrs per MIL-HDBK-217F Environmental Operating Temperature• 0 °C to +60 °C, derate from 100% power at +40 °C to 50% power at +60 °C Cooling • Convection-cooled Operating Humidity • 10-95% RH, non-condensing Storage Temperature • -20 °C to +80 °C Operating Altitude • 3000 m Shock • 30 g, 10 ms on 3 axes Vibration • 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes EMC & Safety Emissions • EN55011/FCC/VCCI, Class B conducted EN55011/FCC/VCCI, Class B radiated Harmonic Currents • EN61000-3-2, Class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, level 3 Perf Criteria A Radiated Immunity • EN61000-4-3, level 2 Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, level 3 Perf Criteria A Conducted Immunity • EN61000-4-6, 3 V Perf Criteria A Magnetic Field • EN61000-4-8, 3 A/m Perf Criteria A Dips & Interruptions• EN61000-4-11, 70% UT for 10 ms, 40% U T for 100 ms, <5% UT for 5000 ms Perf Criteria A, B, B (Perf Criteria A, A, B with 70% load) Safety Approvals • EN60601-1, UL60601-1, CSA22.2 No. 601-1 per cUL, CE Mark
Regulation(2) Model Number (3, 4) 60 W 5.0 V 12.00 A 5% AMM90PS05 60 W 6.0 V 10.00 A 5% AMM90PS06 70 W 9.0 V 7.78 A 5% AMM90PS09 80 W 12.0 V 6.67 A 5% AMM90PS12 85 W 13.5 V 6.30 A 5% AMM90PS13 85 W 15.0 V 5.67 A 5% AMM90PS15 90 W 18.0 V 5.00 A 5% AMM90PS18 90 W 19.0 V 4.74 A 5% AMM90PS19 90 W 24.0 V 3.75 A 5% AMM90PS24 90 W 30.0 V 3.00 A 5% AMM90PS30 90 W 48.0 V 1.87 A 5% AMM90PS48 3.00 (76.2) 5.12 (130.0) Cable length approx 48” (1219mm) 1.72 (43.7) Rubber foot (4 places.) AC Input 0.02 (0.5) IEC 320-C14 Inlet - For Class I version IEC 320-C18 Inlet - For Class II version 2. Maximum load per pin on output connector is 7.5 A. 3. Output connector for AMM90PS05 and PS06 is 5 pin 180° DIN. 4. Output connector for AMM90PS09-PS13 is KYCON KPP-4P non locking type. For mating half, use KYCON KPJ-4S-S or equivalent. 5. Output connector for AMM90PS15-PS48 is KYCON KPP-4P locking type. For mating half, use KYCON KPJ-4S-S or equivalent. 6. For Class I versions shell is connected to ground. For Class II versions shell is capacitively coupled to input. 7. Weight: 1.46 lb (660 g). Mechanical Details Notes 1. Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and 0.1 µF ceramic cap connected at the measurement point. 2. Total regulation includes initial set accuracy, line and load regulation. 3. For class II versions, add ‘C2’ to model number e.g. AMM90PS24C2. 4. For optional Barrel Jack Connector, add ‘B1’ to model number e.g. AMM90PS24C2B1 (not available on 5 V or 6 V models). Optional Barrel Jack Connector 0.433 (11.0) 0.083 (2.1) 0.413 (10.5) 0.217 (5.5) Notes PIN CONNECTIONS PS09 - PS48 Pin Function