AMM XPPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
- CEC2008 & EISA2007 Compliant
- Worldwide Medical Approvals
- Class I and Class II Versions
- High Power Density
- High Efficiency
- Operating Temperature up to +60 °C
- 3 Year Warranty AMM Series Input Input Voltage • 90 W: 80-264 VAC, derate output power 10% <90 VAC & 15% <85 VAC, 120/150 W: 80-264 VAC, derate output power 15% <90 VAC & 20% <85 VAC Input Frequency • 47-63 Hz Input Current • 90 W: 1.2 A at 115 VAC, 0.6 A at 230 VAC 120 W: 1.6 A at 115 VAC, 0.8 A at 230 VAC 150 W: 2 A at 115 VAC, 1.0 A at 230 VAC Inrush Current • 60 A max at 115 VAC, 120 A max at
230 VAC, cold start +25 °C
Power Factor • 0.98 typical Earth Leakage Current• 90 µA max at 115 VAC/60 Hz, (Class I Versions) 150 µA max at 230 VAC/50 Hz Input Protection • 90 W: Internal T2.5 A/250 V fuse in line and neutral lines, 120 W: Internal T3.15 A/250 V fuse in line and neutral lines,
150 W: Internal T4 A/250 V fuse in line and
No Load Input Power • <0.5 W Output Output Voltage • See tables Output Voltage Trim • Not user-adjustable Initial Set Accuracy• ±2%, set at 60% load Minimum Load • No minimum load required Start Up Delay • 90/120 W: 2 s max at 115 VAC,
150 W: 3 s max at 115 VAC
Start Up Rise Time • <80 ms at 115 VAC Hold Up Time • 15 ms minimum at full load & 115 VAC Line Regulation • 0.5% maximum Load Regulation • See tables Transient Response • 4% max. deviation, recovery to within 1% in 500 µs for a 25% load change Ripple & Noise • 2% max pk-pk (see note 1) Overvoltage Protection• 110-140% Vnom, recycle input to reset Overtemperature • 90/150 W: Unit shuts down, auto recovery Protection 120 W: Unit shuts down, recycle input to reset Overload Protection • 110-180%, auto recovery Short Circuit Protection• Trip and restart (Hiccup mode) Temperature • 0.04%/°C Coefficient xppower.com General Efficiency • 85% typical Isolation • 4000 VAC Input to Output
1500 VAC Input to Ground (Class I only)
500 VAC Output to Ground (Class I only)
Switching Frequency • 50-110 kHz variable Power Density • 90 W: 3.4 W/In3, 120 W: 3.7 W/In3 150 W: 2.9 W/In3 MTBF • 150 kHrs typical to MIL-HDBK-217F at 25 şC, GB Environmental Operating Temperature• 0 °C to +60 °C, derate linearly from 100% power at +40 °C to 50% power at +60 °C Cooling • Convection-cooled Operating Humidity • 5-95% RH, non-condensing Storage Temperature • -40 şC to +85 şC Operating Altitude • 3000 m Shock • 30 g, 10 ms on 3 axes Vibration • 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes EMC & Safety Emissions • EN55011/FCC/VCCI, Class B conducted EN55011/FCC/VCCI, Class B radiated Harmonic Currents • EN61000-3-2, Class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, level 3 Perf Criteria A Radiated Immunity • EN61000-4-3, level 2 Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, level 3 Perf Criteria A Conducted Immunity • EN61000-4-6, 3 V Perf Criteria A Magnetic Field • EN61000-4-8, 3 A/m Perf Criteria A Dips & Interruptions• EN61000-4-11 90/120 W: 70% 10 ms, 40% 100 ms, <5% 5000 ms, Perf Criteria A, B, B (Perf Criteria A, A, B with 70% load)
150 W: >95% 10 ms, 60% 100 ms,
<30% 500 ms, Perf Criteria A, B, B Safety Approvals • EN60601-1, UL60601-1, CSA22.2 No. 601-1 per cUL
Regulation(2) Model Number (3, 4) 60 W 5.0 V 12.00 A 5% AMM90PS05(5) 60 W 6.0 V 10.00 A 5% AMM90PS06(5) 70 W 9.0 V 7.78 A 5% AMM90PS09(5) 80 W 12.0 V 6.67 A 5% AMM90PS12 85 W 13.5 V 6.30 A 5% AMM90PS13 85 W 15.0 V 5.67 A 5% AMM90PS15 90 W 18.0 V 5.00 A 5% AMM90PS18 90 W 19.0 V 4.74 A 5% AMM90PS19 90 W 24.0 V 3.75 A 5% AMM90PS24 90 W 30.0 V 3.00 A 5% AMM90PS30 90 W 48.0 V 1.87 A 5% AMM90PS48 3.00 (76.2) 5.12 (130.0) Cable length approx 48” (1219mm) 1.72 (43.7) Rubber foot (4 places.) AC Input 0.02 (0.5) 1 3 IEC 320-C14 Inlet - For Class I version IEC 320-C18 Inlet - For Class II version 1.Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2.Weight: 1.46 lb (660 g). 3.Maximum load per pin on output connector is 7.5 A. 4.Output connector for AMM90PS05 and PS06 is 5 pin 180° DIN. 5. Output connector for AMM90PS09-PS13 is 4 Pin DC Power Plug non locking type. For mating half, use KYCON KPJ-4S-S or equivalent. 6.Output connector for AMM90PS15-PS48 is 4 Pin DC Power Plug locking type. For mating half, use KYCON KPJ-4S-S or equivalent. 7.For Class I versions shell is connected to ground. For Class II versions shell is capacitively coupled to input. 8. For European mains lead order part: EU-MAINS-IEC 9. For UK mains lead order part: UK-MAINS-IEC 10. For US mains lead order part: US-MAINS-IEC 11. Mains lead length is 76“ (1930 mm) approx Mechanical Details Notes 1. Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and 0.1 µF ceramic cap connected at the measurement point. 2. Total regulation includes initial set accuracy, line and load regulation. 3. For class II versions, add ‘ C2’ to model number e.g. AMM90PS24C2. 4. For optional Barrel Jack Connector, add ‘ B1’ to model number e.g. AMM90PS24C2B1 (not available on 5 V or 6 V models). 5. Not CEC2008 or EISA2007 compliant. Optional Barrel Jack Connector 0.433 (11.0) 0.083 (2.1) 0.413 (10.5) 0.217 (5.5) Notes PIN CONNECTIONS PS09 - PS48 Pin Function
1 Return
2 Output+
3 Return
4 Output+
2 Return
3 Output+
4 Return
5 Output+
Regulation(2) Model Number (3, 4) 96 W 12 V 8.00 A 5% AMM120PS12 105 W 15 V 7.00 A 5% AMM120PS15 120 W 18 V 6.67 A 5% AMM120PS18 120 W 19 V 6.32 A 5% AMM120PS19 120 W 20 V 6.00 A 5% AMM120PS20 120 W 24 V 5.00 A 5% AMM120PS24 120 W 30 V 4.00 A 5% AMM120PS30 120 W 36 V 3.34 A 5% AMM120PS36 120 W 48 V 2.50 A 5% AMM120PS48 Notes 1. Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and 0.1 µF ceramic cap connected at the measurement point. 2. Total regulation includes initial set accuracy, line and load regulation. 3. For Class II versions, add ‘ C2’ to model number e.g. AMM120PS24C2. 4. For optional barrel jack connector add suffix ‘ B1’ to model number e.g. AMM120PS24C2B1. 3.00 (76.2) 6.30 (160.0) Cable length approx 48” (1220mm) Power On Indicator 1.72 (43.7) Rubber foot (4 places.) AC Input 0.02 (0.5) 1 3 IEC 320-C14 Inlet - For Class I version IEC 320-C18 Inlet - For Class II version 1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Weight 1.72 lbs (780 g). 3. Maximum load per pin on output connector is 5 A. 4. Output connector for AMM120PS12 & PS15 is 4 Pin DC Power Plug, non-locking type. For mating half, use KYCON KPJ-4S-S or equivalent. 5. Output connector for AMM120PS18-PS48 is 4 Pin DC Power Plug, locking type. For mating half, use KYCON KPJ-4S-S or equivalent. 6. For Class I versions shell is connected to ground. For Class II versions shell is capacitively coupled to input. 7. For European mains lead order part: EU-MAINS-IEC 8. For UK mains lead order part: UK-MAINS-IEC 9. For US mains lead order part: US-MAINS-IEC 10. Mains lead length is 76“ (1930 mm) approx Pin Function Optional Barrel Jack Connector 0.433 (11.0) 0.083 (2.1) 0.413 (10.5) 0.217 (5.5) Notes 1 3 AC-DC
3.23 (82.0) 8.17 (207.6) Cable length approx 48” (1219 mm) Power On Indicator 1.96 (49.7) Rubber foot (4 places.) AC Input 0.02 (0.5) 1 3 IEC 320/C14 Inlet - For Class I Version IEC 320/C18 Inlet - For Class II Version AMM150Models and Ratings Notes 1. Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and 0.1 µF ceramic capacitor connected at the measurement point. 2. Total regulation includes set accuracy, line and load regulation. 3. For optional barrel jack connector, add suffix ‘ B1’ to the model number e.g. AMM150PS24B1 (not available on 12 V models) 4. For optional AC cable restraint on the Class I Version, add suffix ‘ A’ to the model number e.g. AMM150PS24A or AMM150PS24B1A. AC mains lead must be Interpower Corporation, part number: 70006020300. Optional AC cable restraint is not available on the Class II Version. 5. For Class II Versions, and ‘ C2’ to model number, eg. AMM150PS24C2. 6. Energy Star Level V. 1. Dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Weight: 2.16 lbs (980 g). 3. Output connector is 4 Pin DC Power Plug, locking type. For mating half, use KYCON KPJX-4S-S or equivalent. 4. For Class I versions shell is connected to ground. For Class II Versions shell is capacitively coupled to input. 5. For European mains lead order part: EU-MAINS-IEC 6. For UK mains lead order part: UK-MAINS-IEC 7. For US mains lead order part: US-MAINS-IEC 8. Mains lead length is 78“ (2000 mm) approx Pin Function Regulation(2) Model Number (4,5) 132 W 12 V 11.00 A 5% AMM150PS12 144 W 15 V 9.60 A 5% AMM150PS15 150 W 19 V 7.90 A 5% AMM150PS19(6) 150 W 24 V 6.25 A 5% AMM150PS24(3,6) 150 W 27 V 5.56 A 5% AMM150PS27(3,6) 150 W 48 V 3.13 A 5% AMM150PS48(3,6) Optional Barrel Jack Connector 0.433 (11.0) 0.083 (2.1) 0.413 (10.5) 0.217 (5.5) Mechanical Details 1 3 AC-DC