150 Watts

  • Energy Star Level V
  • CEC2008 & EISA2007 Compliant
  • Universal Input
  • High Efficiency
  • 0 °C to +70 °C Operating Temperature
  • Non-standard Connectors Available
  • International Safety Approvals AMD150 Series Input Input Voltage • 90-264 VAC Input Frequency • 47-63 Hz Input Current • 2.0 A rms at 115 VAC,

1.0 A rms at 230 VAC

Inrush Current • 60 A at 115 VAC, 120 A at 230 VAC, cold start +25 °C Input Protection • Internal T4A/250 V fuse Power Factor • 0.95 typical Earth Leakage Current• 150 µA max at 115 VAC, 250 µA max at 230 VAC No Load Input Power • <0.5 W Output Output Voltage • See table Output Voltage Trim • Not user-adjustable Initial Set Accuracy • ±2% Minimum Load • No minimum load required Start Up Delay • 5 s max at 100 VAC Hold Up Time • 3 ms minimum at 100 VAC Line Regulation • ±0.5% maximum Load Regulation • See table Transient Response • 4% max. deviation, recovery to within 1% in 500 µs for a 25% load change Ripple & Noise • 2% max pk-pk (see note 1) Overvoltage Protection• 110-140% Vnom, recycle input to reset Overtemperature • Unit shuts down, recycle input to reset Protection Overload Protection • 110-150%, auto recovery Short Circuit Protection• Trip and restart (Hiccup mode) Temperature • 0.04%/°C Coefficient xppower.com General Efficiency • 88% min Isolation • 3000 VAC Input to Output

1500 VAC Input to Ground

Output 0 V is electrically connected to Input Ground Switching Frequency • 20-80 kHz variable Power Density • 5.1 W/In3 MTBF • >100 kHrs per MIL-HDBK-217F (+25 °C ambient at full load) Environmental Operating Temperature• 0 °C to +70 °C, derate from 100% power at +40 °C to 60% power at +70 °C Operating Humidity • 10-95% RH, non-condensing Storage Temperature • -20 °C to +80 °C Operating Altitude • 3000 m Shock • 30 g, 10 ms on 3 axes Vibration • 5-100 Hz, 2.31 m/s2, 20 mins, 3 axes EMC & Safety Emissions • EN55022/FCC/VCCI, Class B conducted EN55022/FCC/VCCI, Class B radiated Harmonic Currents • EN61000-3-2 Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, ±15 kv contact and air discharge Radiated Immunity • EN61000-4-3, level 2 Perf Criteria A EFT/Burst • EN61000-4-4, level 2 Perf Criteria A Surge • EN61000-4-5, level 3 Perf Criteria A Conducted Immunity • EN61000-4-6, level 2 Perf Criteria A Dips & Interruptions • EN61000-4-11, 30% for 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B Safety Approvals • EN60950, UL60950, CSA22.2 No. 60950 per cUL, CE Mark

  1. Ripple and noise measured at 20 MHz bandwidth with a 47 µF tantalum and 0.1 µF ceramic cap connected at the measurement point. 2. Total regulation includes initial set accuracy, line and load regulation. 2.83 (72.0) 6.73 (171.0) Cable length approx 70.9” ±1.97” (1800mm ±50mm)(4) Power On Indicator 1.55 (39.5) Rubber foot (4 places.) AC Input IEC 320/C14 Inlet 0.02 (0.5) 1 3 2. Weight: 1.76 lb (800 g). 3. Optional output connectors available. Consult sales. 4. AMD150PS12 cable length is 37.4” (950 mm). 5. Output connector is non locking 4 pin DC power plug and mates with Kycon KPJ-4S or equivalent. Pin Function

1 Output +

2 Output +

3 Return/Input Earth

4 Return/Input Earth

Current Total Regulation(2) Model Number 150 W 12 V 12.50 A 5% AMD150PS12 150 W 19 V 7.89 A 5% AMD150PS19 150 W 24 V 6.25 A 5% AMD150PS24 Notes