A LM 200 Series AC -D C Pow er Supplies The ALM200 series of medical external power supplies is fully approved to international medical & IT safety standards. It has been designed with very high efficiency and low standby power, enabling it to meet the latest environmental legislation. The unit has a fully sealed enclosure complying with IP32 and a smooth surface finish making it easier to wipe down in a clinical setting.
- M edical & IT Safety A pprovals
- Energy Efficiency Level VI & EU CoC Tier 2 Com pliant
- 4th Edition M edical EM C
- IP32 Environm ental Rating
- Class I and Class II Versions
- <0 .15 W Standby Pow er
- 0 °C to 60 °C O peration
- Low Earth Leakage Current
- 3 Year W arranty 20 0 W atts Dim ensions: A LM 200: w w w .xppow er.com 1 M odels & Ratings N otes O utput Pow er O utput Voltage O utput C urrent Load R egulation Efficiency (4) M odel N um ber (1,2,3) 20 0 W 12.0 V 16.7 A 3 .5 % 91.7% ALM 20 0 PS12 15 .0 V 13 .4 A 92.4% ALM 20 0 PS15 19.0 V 10 .6 A 3 .0 % 92.8% ALM 20 0 PS19 24.0 V 8.4 A 92.2% ALM 20 0 PS24 48.0 V 4.2 A 92.4% ALM 20 0 PS48 1. For class II versions, add suffix 'C 2 -8' to the end of the part num ber e.g. A LM 2 00P S 2 4 C 2 -8. 2 . For optional input connector retention clip add suffix ‘-A ’ to the m odel num ber, e.g. A LM 2 00P S 2 4 -A (not available for C 2 versions) 3 . Pow er de-rated <100 VAC for 12 & 15 V m odels, refer to input specifications. 4 . T ypical average value m easured at 2 5% , 50% , 75% and 100% load at 2 3 0VAC 1. All dim ensions show n in inches (m m ). T olerance is 0 .0 2 (0 .5 ) m axim um , except output cable length. 2. W eight: 2.0 1 lbs (910 kg) approx. 3 . For European m ains lead order part EU -M AIN S-IEC for C 14 versions, or EU - M AIN S-8 for C 8 versions. 4. For U K m ains lead order part U K-M AIN S-IEC for C 14 versions, or U K-M AIN S-8 for C 8 versions. 5 . For U S m ains lead order part U S-M AIN S-IEC for C 14 versions, or U S-M AIN S-8 for C 8 versions. 6. O utput connector: 4 pin m olex M ini-Fit part num ber 3 9-0 3 -90 42 housing w ith 45 75 0 crim p term inals and m ates w ith m olex header 46999-0 5 16 or equivalent. N otes M echanical Details 0.193 (4.9) 3.2 (82. 0) 1.69 (43. 0) 7.48 (190.0) 5.12 (130.2) 0.063 (1. 6) 2.5 (63. 5) 1.97 (50. 2) Class I AC Input IEC 320-C14 Optiona l Class II AC Input IEC 320- C8 Mole x 39-03-9042 Pin C onnection
1 RTN
2 RTN
w w w .xppow er.com 2 AC -D C Pow er Supplies Input C haracteristic M inim um Typical M axim um U nits N otes & C onditions Input Voltage 80 264 VAC 19, 24 & 48V m odels: D erate linearly from 10 0 % load at 90 VAC to 80 % load at 80 VAC . 3 0 0 VAC /5 s m axim um . 12 & 15 V m odels: D erate linearly from 10 0 % load at 10 0 VAC to 95 % load at 90 VAC and then derate linearly 80 % load at 80 VAC , 3 0 0 VAC /5 s m axim um . Input Frequency 47 63 H z Input C urrent 2.0 /1.0 A M easured at 115 /23 0 VAC Inrush C urrent 160 A 23 0 VAC , cold start at 25 °C Pow er Factor >0 .9 EN 610 0 0 -3 -2 C lass A Earth Leakage C urrent 25 0 µA 264 VAC , 60 H z N o Load Input Pow er 0 .15 W Input Protection T5 A/25 0 VAC internal fuse in both line & neutral O utput C haracteristic M inim um Typical M axim um U nits N otes & C onditions O utput Voltage 12 48 VD C See M odels and Ratings table Initial Set Accuracy ±2 % At 5 0 % load M inim um Load N o m inim um load required Start U p D elay 1 1.5 s Start U p Rise Tim e 40 m s H old U p Tim e 20 3 0 m s Full load and 115 /23 0 VAC Line Regulation ±0 .5 % Load Regulation % See M odels and Ratings table T ransient Response 4% M axim um deviation, recovering to less than 1% w ithin 5 0 0 µs for 5 0 -75 -5 0 % load change Ripple and N oise 1.5 % pk-pk 20 M H z bandw idth, m easured w ith 20 M H z B andw idth and 10 µF electrolytic in parallel w ith 0 .1 µF ceram ic capacitor. O vershoot 5 10 % At turn on / turn off O verload Protection 115 175 % O vervoltage Protection 15 0 % Recycle m ains to reset Short C ircuit Protection T rip and restart (hiccup), auto resetting Therm al Protection M easured internally, auto resetting T em perature C oefficient 0 .0 2 % /°C Patient Leakage C urrent 95 µ A 264 VAC , 60 H z Environm ental C haracteristic M inim um Typical M axim um U nits N otes & C onditions O perating T em perature 0 +60 °C D erate from 10 0 % load at 40 °C to 3 5 % load at 60 °C C ooling N atural convection O perating H um idity 5 95 % RH N on-condensing Storage T em perature -25 +80 °C O perating Altitude 5 0 0 0 m Shock IEC 68-2-27 , 3 0 g, 11 m s half sine, 3 tim es in each of 6 axes Vibration IEC 68-2-6, 10 -5 0 0 H z, 2 g 10 m ins/sw eep, 60 m ins for each of 3 axes 60% 20% 40% 80% Ambient Temperature (ºC) Output Power (%) 100% 40 6020 D erating C urve
w w w .xppow er.com 3 AC -D C Pow er Supplies EM C: Em issions Phenom enon Standard Test Level N otes & C onditions Em issions EN 5 5 0 3 2 Level B C onducted & Radiated H arm onic C urrent EN 610 0 0 -3 -2 C lass A Voltage Flicker EN 610 0 0 -3 -3 G eneral C haracteristic M inim um Typical M axim um U nits N otes & C onditions Efficiency 92 % See M odels and Ratings table Isolation: Input to O utput Input to G round O utput to G round 40 0 0 VAC 2 x M O PP 180 0 VAC 1 x M O PP (C lass I versions only) 5 0 0 VAC C lass I versions only Sw itching Frequency 45 140 kH z PFC 85 190 M ain C onverter Pow er D ensity 6.4 W /in 3 M ean Tim e B etw een Failure >3 0 0 kH rs M IL-H D B K-217F at 25 °C G B W eight 2.0 1 (910 ) lb (g) 60% 70% 80% 90% 100 % 10% 2 0% 3 0% 4 0% 5 0% 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 % Efficiency Loa d Efficiency C urves ALM 200 PS12 115 V 230 V 60% 70% 80% 90% 100 % 10% 2 0% 3 0% 4 0% 5 0% 6 0 % 7 0 % 8 0 % 9 0 % 1 0 0 % Efficiency Loa d ALM 200 PS24 EM C: Im m unity Phenom enon Standard Test Level C riteria N otes & C onditions ESD EN 610 0 0 -4-2 3A ±15 kV air/±8 kV contact Radiated EN 610 0 0 -4-3 10 V/m A 80 -270 0 M H z. IEC 60 60 1 -1 -2 Ed.4 at other frequencies EFT/B urst EN 610 0 0 -4-4 3A Surge EN 610 0 0 -4-5 Installation C lass 3 A C onducted EN 610 0 0 -4-6 10 V A M agnetic Fields EN 610 0 0 -4-8 4A D ips and Interruptions EN 610 0 0 -4-11 D ip: 3 0 % 5 0 0 m s A D ip: 60 % 20 0 m s A/B H igh Line/Low Line D ip: 20 % 5 0 0 0 m s A Int: 10 0 % 10 m s A Int: 10 0 % 20 m s A Int: 10 0 % 5 0 0 0 m s B EN 60 60 1-1-2 D ip: 3 0 % 25 AC C ycles A D ip: 60 % 5 AC C ycles A 23 0 VAC 10 0 % load, 10 0 VAC 25 % load Int: 10 0 % 0 .5 AC C ycles A Int: 10 0 % 1.0 AC C ycles A Int: 10 0 % 25 0 AC C ycles B
w w w .xppow er.com AC -D C Pow er Supplies Safety A pprovals Safety Agency Safety Standard N otes & C onditions U L U L62368-1 Inform ation T echnology TU V EN 62368-1 C B IEC 60950-1 & IEC 62368-1 C E LVD U L AN SI/AAM I ES 60601-1 / AN SI/AAM I H A60601-1-11 M edical 60 60 1-1-11 is only for C lass II versions C SA C SA C 22.2 N o. 60601 / C AN /C SA-C 22.2 N o. 60601-1-11 TU V EN 60601-1 / EN 60601-1-11 C B IEC 60601-1 / IEC 60601-1-11 O thers C C C , PSE, KC & RC M M ay require additional im porter inform ation 1. All dim ensions show n in inches (m m ). T olerance is 0 .0 2 (0 .5 ) m axim um , except output cable length. 2. W eight: 2.0 1 lbs (910 kg) approx. 3 . For European m ains lead order part EU -M AIN S-IEC for C 14 versions, or EU - M AIN S-8 for C 8 versions. 4. For U K m ains lead order part U K-M AIN S-IEC for C 14 versions, or U K-M AIN S-8 for C 8 versions. 5 . For U S m ains lead order part U S-M AIN S-IEC for C 14 versions, or U S-M AIN S-8 for C 8 versions. 6. O utput connector: 4 pin m olex M ini-Fit part num ber 3 9-0 3 -90 42 housing w ith 45 75 0 crim p term inals and m ates w ith m olex header 46999-0 5 16 or equivalent N otes M echanical Details 0.193 (4.9) 3.2 (82. 0) 1.69 (43. 0) 7.48 (190.0) 5.12 (130.2) 0.063 (1. 6) 2.5 (63. 5) 1.97 (50. 2) Class I AC Input IEC 320-C14 Optiona l Class II AC Input IEC 320- C8 M l 39 03 9042 Mole x 39-03-9042 Pin C onnection