ABW-100-B IDEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 41

Technical content

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 696 www.IDEC.com 1904032203 TW Series — 22mm NEMA Style Pushbuttons Key features:

  • TW NEMA Style Switches with snap-on contacts
  • Corrosion resistant octagonal chrome plated locking bezel
  • Snap-on 10A contact blocks
  • LED illumination
  • Slow make, double break, contacts
  • Modular construction for maximum flexibility
  • Type 4X and IP65 watertight/oiltight panel
  • Available assembled or as sub-components
  • Finger-Safe - Spring-Up
  • Large M3.5 screw terminals with captive sems plate IDEC has your 22mm switching needs covered. Button styles include flush, extended, mushroom, or square and all bodies are crafted from fracture-resistant nylon. All illuminated units feature two lens styles, one that maximizes light dispersion, the other accommodates direct lens engraving. Contact mechanism allow for a wide current rating, 5mA to 10A, which reduces the need for various contact materials. When looking for a 22mm switch that is durable, easy to use, and versatile, then IDEC’s TW series is your solution. UL Listed File No. E68961 CSA Approved File No. LR21451 File No. DK95-01696 Certificate No. 2030010305027380

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 697 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Specifications Conforming to Standards EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14 Approvals File No. E68961 File No. LR21451 Certificate No. 2030010305027380 Registration No: J9551802 (E-Stops) Registration No: J9551803 (All other switches) Registration No: J9551804 (Pilot Lights) CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) TÜV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) Operating Temperature Operation: –25 to +50°C (without freezing), Storage: –40 to +80°C (without freezing) Vibration Resistance 5 to 55Hz, 100m/sec2 (10g) conforming to IEC6068-2-6 Shock Resistance 1000m/sec2 (100g) conforming to IEC6068-2-7 Electric Shock Protection Class 2 conforming to IEC60664-7 Degree of Protection (conforming to IEC60529) (conforming to NEMA ICS6-110) IP65 from front of the panel; (IP54 for key switches) IP20 (Type HW-U contact block) Type 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (Type 1, 2, 3R, 5, 12, 13 for key switches) Mechanical Life Momentary pushbuttons: 5,000,000 (1800 operations per hour) All other switches: 500,000 Pollution Degree (conforming to IEC60947-1) 3 Rated Operational Characteristics AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB) DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC) DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB) Rated Insulation Voltage 600V Rated Switching Over-Voltage Less than 4kV, conforming to IEC60947-1 Rated Impulse Withstanding Voltage 4kV for contact circuit, 2.5kV for lamp circuit Rated Thermal Current 10 Amp Minimum Switching Capacity 5 mA at 3V AC/DC Contact Operation Slow break NC or slow make NO, self-cleaning Recommended Terminal Torque Unit Wire Number of Wires Recommended Tightening Torque (Nm) Terminal Screw HW-U Contact Block Crimping Terminal 2 1.0 to 1.3 ø1.7 to 2.0 mm (AWG12) 1 1.2 to 1.3 Stranded Wire 0.3 to 2.0 mm2 (AWG14 to 22) 2 1.0 to 1.3 2.1 to 3.5 mm2 (AWG12) 1 1.2 to 1.3 Illuminated Unit (*1) Crimping Terminal Stranded Wire 0.3 to 2.0 mm (AWG14 to 22) Applicable Wire Size Pilot Light Crimping Terminal 0.6 to 1.0 (M3.0) 1.0 to 1.3 (M3.5) Solid Wire ø0.5 to 1.6 mm (AWG14 to 22) Stranded Wire ø0.3 to 2.0 mm (AWG14 to 22) 1. * refers to the lamp terminals of the illuminated push buttons and selector switches. External Short-Circuit Protection 10A 250V fuse conforming to IEC60269-1 Applicable Wire Size Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG Contact Resistance Initial contact resistance of 50mΩ or less Contact Gap 4mm (NO and NC), 2mm (NO-EM and NC-LB) Electrical Reliability MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA) Lamp Ratings LEDs: 6V: 17mA max, 12/24V: 11mA max, 120/240V: 10mA max Horsepower Rating 1/4 HP @ 120V (single-phase, non-reversing motor); 1 HP @ 240V (3 phase, non-reversing motor) Contact Material Silver Contact Ratings Pushbuttons Illuminated Pushbuttons Selector Switches Illuminated Selector Switches Pushbutton Selectors Contact Block Type HW-U Rated Insulation Voltage 600V Rated Continuous Current 10A Contact Ratings by Utilization Category IEC 60947-5-1 AC-15 (A600) DC-13 (P600) Characteristics Contact Ratings by Utilization Category Operational Voltage 24V 48V 50V 110V 220V 440V Operational Current AC50/60Hz AC-12 Control of resistive loads and solid state loads 10A — 10A 10A 6A 2A AC-15 Control of electromagnetic loads (> 72VA) 10A — 7A 5A 3A 1A DC DC-12 Control of resistive loads and solid state loads 10A 5A — 2.2A 1.1A — DC-13 Control of electromagnets 5A 2A — 1.1A 0.6A —

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 698 www.IDEC.com 1904032203 Non-Illuminated Pushbuttons (Assembled) Assembled Pushbuttons A B ( ) W 1 10 – B Function B: Momentary O: Maintained K: Key On/Off Lock Bezel Shape Blank: Octagonal F: Full Shroud G: Mushroom Shroud Q: Square Button Color B: Black G: Green W: White R: Red S: Blue Y: Yellow Contact Arrangement 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO-1NC 22: 2NO-2NC Button Shape 1: Flush 2: Extended 3: Mushroom Head Ø 29mm 4: Mushroom Head Ø 40mm Series Designation W: TW Series To be used for interpreting part numbers only, not for part number development.

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 699 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Non-Illuminated Pushbuttons (Assembled) continued Non-Illuminated Pushbuttons Style Contacts Momentary Action Maintained Action Flush 1NO 1NC 1NO-1NC 2NO 2NC ABW110-j ABW101-j ABW111-j ABW120-j ABW102-j AOW110-j AOW101-j AOW111-j AOW120-j AOW102-j Extended 1NO 1NC 1NO-1NC 2NO 2NC ABW210-j ABW201-j ABW211-j ABW220-j ABW202-j AOW210-j AOW201-j AOW211-j AOW220-j AOW202-j Recessed 1NO 1NC 1NO-1NC 2NO 2NC ABFW110-j ABFW101-j ABFW111-j ABFW120-j ABFW102-j AOFW110-j AOFW101-j AOFW111-j AOFW120-j AOFW102-j Extended with Full Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABFW210-j ABFW201-j ABFW211-j ABFW220-j ABFW202-j AOFW210-j AOFW201-j AOFW211-j AOFW220-j AOFW202-j Ø 29mm Mushroom Head 1NO 1NC 1NO-1NC 2NO 2NC ABW310-j ABW301-j ABW311-j ABW320-j ABW302-j AOW310-j AOW301-j AOW311-j AOW320-j AOW302-j Ø 40mm Mushroom Head 1NO 1NC 1NO-1NC 2NO 2NC ABW410-j ABW401-j ABW411-j ABW420-j ABW402-j AOW410-j AOW401-j AOW411-j AOW420-j AOW402-j Ø 40mm Mushroom Head with Full Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABGW410-j ABGW401-j ABGW411-j ABGW420-j ABGW402-j AOGW410-j AOGW401-j AOGW411-j AOGW420-j AOGW402-j Square Flush 1NO 1NC 1NO-1NC 2NO 2NC ABQW110-j ABQW101-j ABQW111-j ABQW120-j ABQW102-j AOQW110-j AOQW101-j AOQW111-j AOQW120-j AOQW102-j Square Extended 1NO 1NC 1NO-1NC 2NO 2NC ABQW210-j ABQW201-j ABQW211-j ABQW220-j ABQW202-j AOQW210-j AOQW201-j AOQW211-j AOQW220-j AOQW202-j Keylock Push On/ Off 1NO 1NC 1NO-1NC 2NO 2NC AKW210 AKW201 AKW211 AKW220 AKW202 1. In place of j, specify the Button Color Code from table. 2. For sub-assembled part numbers, see next page. 3. For accessories, see page 728. 4. For dimensions, see page 730. 5. Keyed switches are supplied with two keys. All units are keyed alike. j Button Color Codes Color Code Black B Green G Red R Blue S Yellow Y White W

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 700 www.IDEC.com 1904032203 Non-Illuminated Pushbuttons (Sub-Assembled) Contact Blocks + Operator + Button = Complete Part Operators Style Part Number Momentary Maintained Round Flush/Extended ABW-100 AOW-100 Round with Full Shroud/Recessed ABFW-200 AOFW-200 Ø 40mm, Ø 29mm Mushroom Head ABW-300 AOW-300 Ø 40mm Mushroom Head with Full Shroud ABGW-400 AOGW-400 Square Flush/Extended ABQW-100 AOQW-100 Keylock Push On/Off — AKW-200 Buttons Style Part Number Round Flush ABW1B-j Round Extended ABW2B-j Ø 29mm Mushroom ABW3B-j Ø 40mm Mushroom ABW4B-j Square Flush ABQW1B-j Square Extended ABQW2B-j In place of j specify the button color code from table Contact Blocks Style Contacts 1NO 1NC Finger- Safe Spring-Up Terminal HW-U10-F HW-U01-F HW-U10R-F (early make) HW-U01R-F (late break) Dummy Block HW-DB 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function j Button Color Codes Color Code Black B Green G Red R Blue S Yellow Y White W

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 701 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Stop Switches (Assembled) To be used for interpreting part numbers only, not for part number development. Assembled Stop Switches Function V: Pushlock Turn Reset Y: Push-Pull X: Pushlock Key Reset Illumination Blank: None L: Illuminated Series Designation W: TW Series Button/Lens Size 3: 29mm Mushroom 4: 40mm Mushroom Lens Type (illuminated units only) Blank: Standard (ribbed) B: Engravable (smooth with insert) Illuminated Circuit (illuminated unit only) 99: Full Voltage (LED determines voltage) 126: 120V AC Step Down Transformer 246: 240V AC Step Down Transformer 486: 480V AC Step Down Transformer Lamp Voltage (full voltage illuminated units only) 6V: 6V AC/DC 12V: 12V AC/DC 24V: 24V AC/DC 120V: 120V AC 240V: 240V AC Button/Lens Color A: Amber R: Red W: White G: Green S: Blue Y: Yellow B: Black Lamp Type (illuminated units only) D: LED Contact Arrangement 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO/1NC 22: 2NO/2NC

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 702 www.IDEC.com 1904032203 Stop Switches (Assembled), continued Non-Illuminated Stop Switches Style Contacts Part Number Ø 40mm Pushlock Turn Reset* 1NO 1NC 1NO-1NC 2NO 2NC AVW410-R* AVW401-R* AVW411-R* AVW420-R* AVW402-R* Ø 29mm Pushlock Turn Reset* 1NO 1NC 1NO-1NC 2NO 2NC AVW310-R* AVW301-R* AVW311-R* AVW320-R* AVW302-R* Ø 40mm Push-Pull 1NO 1NC 1NO-1NC 2NO 2NC AYW410-j AYW401-j AYW411-j AYW420-j AYW402-j Ø 40mm Pushlock Key Reset * 1NO 1NC 1NO-1NC 2NO 2NC AXW410- R* AXW401- R* AXW411- R* AXW420- R* AXW402- R* 1. *Available in Red only. 2. In place of j, specify the Button Color Code from table. 3. For sub-assembled part numbers, see next page. 4. For accessories, see page 728. 5. For dimensions, see page 730. Illuminated Stop Switches Style Type Contacts Part Number Ø 40mm Pushlock Turn Reset Type Transformer 1NO-1NC 2NO 2NC AVLW4 m 11D-R* AVLW4 m 20D-R* AVLW4 m 02D-R* Full Voltage 1NO-1NC 2NO 2NC AVLW49911D-R*-l AVLW49920D-R*-l AVLW49902D-R*-l Ø 29mm Pushlock Turn Reset Transformer 1NO-1NC 2NO 2NC AVLW3m11D-R* AVLW3m20D-R* AVLW3m02D-R* Full Voltage 1NO-1NC 2NO 2NC AVLW39911D-R*-l AVLW39920D-R*-l AVLW39902D-R*-l Ø 40mm Push-Pull Transformer 1NO-1NC 2NO 2NC AYLW4 m 11D-k AYLW4 m 20D-k AYLW4 m 02D-k Full Voltage 1NO-1NC 2NO 2NC AYLW49911D-k-l AYLW49920D-k-l AYLW49902D-k-l 1. *Available in red only. 2. In place of k, specify the Lens Color Code (see table above). 3. In place of l, specify the Full Voltage Code (lamp voltage) (see table above). 4. In place of m, specify the Transformer Voltage Code (see table above). 5. For sub-assembly part numbers, see next page. 6. For accessories, see page 728. 7. For dimensions, see page 730. j Button Color Codes Color Code Black B Green G Red R Blue S White W Yellow Y k LED/Lens Color Codes Color Code Amber A Green G Red R Blue S White W l Full Voltage Codes Voltage Code 6V AC/DC 6V 12V AC/DC 12V 24V AC/DC 24V 120V AC 120V 240V AC 240V m Transformer Voltage Codes Voltage Code 120VAC 240VAC 480VAC 126 246 486 Transformers step down to 6V.

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 703 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Stop Switches (Sub-Assembled) Transformer/ Adaptor* + Contacts + Lamp Holder + Operator + Lamp + Button or Lens = Complete Part *Not applicable for full voltage units Operators Style Part Number Non-Illuminated Illuminated Ø 29/Ø 40mm Pushlock Turn Reset AVW-300 AVLW3-0600 Ø 40mm Push-Pull AYW-400 AYLW4-0600 Ø 40mm Pushlock Key Reset AXW-300 — Buttons Style Part Number Ø 40mm Pushlock Turn Reset AVW4B-R* Ø 29mm Pushlock Turn Reset AVW3B-R* Ø 40mm Push-Pull AYW4B-j Ø 40mm Pushlock Key Reset AXW4B-R* 1. *Available in Red only 2. In place of j, specify the button color code from table. Lamps Style Voltage Part Number LED 6V AC/DC LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. j Button Color Codes Color Code Black B Green G Red R Blue S White W Yellow Y k LED/Lens Color Codes Color Code Amber A Green G Red R Blue S White W

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 704 www.IDEC.com 1904032203 Illuminated Stop Switches (Sub-Assembled) continued Lenses Style Part Number Standard Engravable Ø 29mm Head Pushlock Turn Reset AVLW3LU-R* AVLW3BLU-R* Ø 40mm Head Pushlock Turn Reset AVLW4LU-R* AVLW4BLU-R* Ø 40mm Head Push Pull AYLW4LU-k AYLW4BLU-k 1. In place of k, specify the lens color code from table on previous page. 2. *Available only in red 3. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an engravable insert. Lamp Circuit Components Style Application Part Number Long Lamp Holder Used with Full-size Transformer and two contact blocks TW-LH2 Lead Holder Used with TW-LH2 holder when using four contact blocks and transformer HW-LH3 Transformers/Full Voltage Modules Style Description Part Number Full Size Transformer Finger-Safe 120V AC TW-F126B 240V AC TW-F246B 480V AC TW-F486B Dummy Block with Full Voltage Adaptor For use with odd number of contacts. Finger-Safe HW-DA1FBN Full Voltage Adaptor For use with even number of contacts. Finger-Safe TW-DA1FB All Transformers step down to 6V (use 6V LED). Contact Blocks Style Contacts 1NO 1NC Finger- Safe Spring-Up Terminal HW-U10-F HW-U01-F HW-U10R-F (early make) HW-U01R-F (late break) Dummy Block HW-DB 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 705 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Pilot Lights (Assembled) Assembled Pilot Lights Function P: Pilot Light Bezel Shape Blank: Octagonal (round lenses) Q: Square Series Designation W: TW Series Lens Shape 1: Flat 2: Dome Lens Type Blank: Standard (ribbed) B: Engravable (smooth with insert included) Illumination Circuit 99: Full Voltage (lamp determines voltage) 126: 120V AC Step Down Transformer 246: 240V AC Step Down Transformer 486: 480V AC Step Down Transformer Lamp Voltage (Full Voltage Units Only) 6V: 6V AC/DC 12V: 12V AC/DC 24V: 24V AC/DC 120V: 120V AC 240V: 240V AC Lens Color Code A: Amber G: Green R: Red S: Blue W: White Y: Yellow Lamp D: LED 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. All transformers step down to 6V.

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 706 www.IDEC.com 1904032203 Pilot Lights (Assembled) continued Assembled Pilot Lights Style Type Voltage Part Number Round Flat Transformer 120VAC 240VAC 480VAC APW1126D-k APW1246D-k APW1486D-k Full Voltage — APW199D-k-l Dome Transformer 120VAC 240VAC 480VAC APW2126D-k APW2246D-k APW2486D-k Full Voltage — APW299D-k-l Square Flat Transformer 120VAC 240VAC 480VAC APQW1B126D-k APQW1B246D-k APQW1B486D-k Full Voltage — APQW1B99D-k-l 1. In place of k, specify the Lens Color Code from table below. 2. In place of l, specify the Full Voltage Code from table below. 3. For accessories, see page 728. 4. For dimensions, see page 730. 5. For sub-assembly part numbers, see next page. 6. Yellow pilot light comes with white LED. k Lens Color Codes Color Code Amber A Green G Red R Blue S White W Yellow Y l Full Voltage Codes Voltage Code 6V AC/DC 6V 12V AC/DC 12V 24V AC/DC 24V 120V AC 120V 240V AC 240V

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 707 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Pilot Lights (Sub-Assembled) Transformer + Operator + Lamp + Lens = Complete Part * Transformer not required for full voltage units. Operators Style Part Number Round Dome/Flat APW-199 Square UPQW-199 Same operator is used for full voltage as for transformer completed units. Lenses Style Part Number Standard Engravable Dome APW2LU-k — Round Flat APW1LU-k APW1BLU-k Square Flat — APQW1BLU-k 1. In place of k, specify the Lens Color Code from table. 2. Standard lenses have a ribbed lens to enhance light dispersion. Marking lenses are smooth and include an engravable insert. Lamps Style Voltage Part Number LED 6V AC/DC LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. 3. Yellow LED not available. Use white LED. Transformers Style Description Part Number Finger-Safe 120V AC TW-F126B 240V AC TW-F246B 480V AC TW-F486B All Transformers step down to 6V (use 6V LED). k LED/Lens Color Codes Color Code Amber A Green G Red R Blue S White W Yellow Y If clear lens is desired, use white marking lens and remove engraving insert

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 708 www.IDEC.com 1904032203 Illuminated Pushbuttons (Assembled) Assembled Illuminated Pushbuttons Function L: Momentary Action OL: Maintained Action Bezel Shape Blank: Octagonal (round lenses) F: Full Shroud (round lenses) Q: Square Series Designation W: TW series Lens Shape/Size 2: Standard Extended (round or square) 3: 29mm Mushroom 4: 40mm Mushroom Lens Type Blank: Standard (ribbed) B: Engravable (smooth with insert) Illumination Circuit 99: Full Voltage (lamp determines voltage) 126: 120V AC Step Down Transformer 246: 240V AC Step Down Transformer 486: 480V AC Step Down Transformer Lamp Voltage (Full Voltage Units Only) 6V: 6V AC/DC 12V: 12V AC/DC 24V: 24V AC/DC 120V: 120V AC 240V: 240V AC Lens Code A: Amber G: Green R: Red S: Blue W: White Y: Yellow Lamp Type D: LED Lamp Contact Arrangement 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO-1NC 22: 2NO-2NC 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Transformers step down to 6V.

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 709 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Illuminated Pushbuttons (Assembled) Illuminated Pushbuttons Style Contacts Part Number Momentary Maintained Extended Lens Transformer 1NO-1NC 2NO 2NC ALW2 m 11D-k ALW2 m 20D-k ALW2 m 02D-k AOLW2 m 11D-k AOLW2 m 20D-k AOLW2 m 02D-k Full Voltage 1NO-1NC 2NO 2NC ALW29911D-k-l ALW29920D-k-l ALW29902D-k-l AOLW29911D-k-l AOLW29920D-k-l AOLW29902D-k-l Extended Lens with Full Shroud Transformer 1NO-1NC 2NO 2NC ALFW2 m 11D-k ALFW2 m 20D-k ALFW2 m 02D-k AOLFW2 m 11D-k AOLFW2 m 20D-k AOLFW2 m 02D-k Full Voltage 1NO-1NC 2NO 2NC ALFW29911D-k-l ALFW29920D-k-l ALFW29902D-k-l AOLFW29911D-k-l AOLFW29920D-k-l AOLFW29902D-k-l ø29mm Mushroom Button Transformer 1NO-1NC 2NO 2NC ALW3 m 11D-k ALW3 m 20D-k ALW3 m 02D-k AOLW3 m11D-k AOLW3 m20D-k AOLW3 m 02D-k Full Voltage 1NO-1NC 2NO 2NC ALW39911D-k-l ALW39920D-k-l ALW39902D-k-l AOLW39911D-k-l AOLW39920D-k-l AOLW39902D-k-l ø40mm Mushroom Button Transformer 1NO-1NC 2NO 2NC ALW4 m 11D-k ALW4 m 20D-k ALW4 m 02D-k AOLW4 m11D-k AOLW4 m20D-k AOLW4 m 02D-k Full Voltage 1NO-1NC 2NO 2NC ALW49911D-k-l ALW49920D-k-l ALW49902D-k-l AOLW49911D-k-l AOLW49920D-k-l AOLW49902D-k-l Square Extended Transformer 1NO-1NC 2NO 2NC ALQW2B m11D-k ALQW2B m20D-k ALQW2B m02D-k AOLQW2B m11D-k AOLQW2B m20D-k AOLQW2B m02D-k Full Voltage 1NO-1NC 2NO 2NC ALQW2B9911D-k-l ALQW2B9920D-k-l ALQW2B9902D-k-l AOLQW2B9911D-k-l AOLQW2B9920D-k-l AOLQW2B9902D-k-l 1. In place of k, specify the Lens Color Code (see table). Mushroom lenses not available in yellow. 2. In place of l, specify the Full Voltage Code (lamp voltage) (see table). 3. In place of m, specify the Transformer Voltage Code (see table). 4. For sub-assembly part numbers, see next page. 5. For accessories, see page 728. 6. For dimensions, see page 730. 7. Light is independent of switch position. 8. Yellow pushbutton comes with white LED. k LED/Lens Color Codes Color Code Amber A Green G Red R Blue S White W Yellow Y 1. Mushroom lenses not available in yellow. 2. Yellow pushbutton comes with white LED. l Full Voltage Codes Voltage Code 6V AC/DC 6V 12V AC/DC 12V 24V AC/DC 24V 120V AC 120V 240V AC 240V m Transformer Voltage Codes Voltage Code 120VAC 126 240VAC 246 480VAC 486 Transformers step down to 6V (use 6V LED).

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 710 www.IDEC.com 1904032203 Illuminated Pushbuttons (Sub-Assembled) Transformer/ Adaptor* + Contacts + Lamp Holder + Operator + Lamp + Lens = Complete Part *Not applicable for full voltage units Operators Style Part Number Momentary Maintained Extended ALW-0600 AOLW-0600 Extended with Full Shroud ALFW-0600 AOLFW-0600 ø29mm/ø40mm Mushroom ALW3-0600 AOLW3-0600 Square/Extended ALQW-2B0600 AOLQW-2B0600 Lenses Style Part Number Standard Engravable Round Extended ALW2LU-k ALW2BLU-k ø 29mm Mushroom Head* ALW3LU-k ALW3BLU-k ø 40mm Mushroom Head* ALW4LU-k ALW4BLU-k Square Extended — ALQW2BLU-k 1. In place of k, specify the lens color code from table on the bottom right. 2. *Mushroom lens not available in yellow. 3. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an engravable insert. Lamps Style Voltage Part Number LED 6V AC/DC LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. Lamp Circuit Components Style Application Part Number Long Lamp Holder Used with Full-size Transformer and two contact blocks TW-LH2 Lead Holder Used with TW-LH2 holder when using four contact blocks and transformer HW-LH3 k LED/Lens Color Codes Color Code Color Code Amber A Blue S Green G White W Red R Yellow Y Yellow LED not available. Use white LED.

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 711 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Illuminated Pushbuttons (Sub-Assembled) continued Contact Blocks Style Contacts 1NO 1NC Finger- Safe Spring-Up Terminal HW-U10-F HW-U01-F HW-U10R-F (early make) HW-U01R-F (late break) Dummy Block HW-DB 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function Transformers/Full Voltage Modules Style Description Part Number Full Size Transformer Finger-Safe 120V AC TW-F126B 240V AC TW-F246B 480V AC TW-F486B Dummy Block with Full Voltage Adaptor For use with odd number of contacts. Finger-Safe HW-DA1FBN Full Voltage Adaptor For use with even number of contacts. Finger-Safe TW-DA1FB All Transformers step down to 6V (use 6V LED).

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 712 www.IDEC.com 1904032203 Non-Illuminated Selector Switches (Assembled) Assembled Selector Switches A S W 3 (1) (L) 20 – 304 Function S: Selector Switch Series Designation W: TW Series Number of Positions 2: 2-Position 3: 3-Position 4: 4-Position 5: 5-Position Spring Return Action Blank: Maintained 1: Spring return from Right (2 or 3 position) 2: Spring return from Left (2 or 3 position) 3: 2-Way spring return from Left and Right (3 position only) Circuit Number (Standard circuits shown on following pages and 720.) Contact Arrangement Code 10: 1NO 01: 1NC 20: 2NO 02: 2NC 40: 4NO 04: 4NC 11: 1NO-1NC 22: 2NO-2NC Operator Style Code Blank: Knob Operator L: Lever Operator K: Key Operator 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Custom contact configurations available. 3. Custom key removable codes available. 4. Portions of part number inside ( ) are optional.

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 713 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Non-Illuminated Selector Switches (Assembled) continued 2-Position Selector Switches Style Part Number Contact Mounting Operator Position Maintained Spring Return from Right Spring Return from Left L R L R L R L R 1NO 1 O O X O Knob Lever Key ASW210 ASW2L10 ASW2K10 ASW2110 ASW21L10 ASW21K10 ASW2210 ASW22L10 ASW22K10 1NC 1 X O O O Knob Lever Key ASW201-116 ASW2L01-116 ASW2K01-116 ASW2101-116 ASW21L01-116 ASW21K01-116 ASW2201-116 ASW22L01-116 ASW22K01-116 1NO 1NC X O O X Knob Lever Key ASW211 ASW2L11 ASW2K11 ASW2111 ASW21L11 ASW21K11 ASW2211 ASW22L11 ASW22K11 2NO 1 O O X X Knob Lever Key ASW220 ASW2L20 ASW2K20 ASW2120 ASW21L20 ASW21K20 ASW2220 ASW22L20 ASW22K20 2NC 1 X X O O Knob Lever Key ASW202-104 ASW2L02-104 ASW2K02-104 ASW2102-104 ASW21L02-104 ASW21K02-104 ASW2202-104 ASW22L02-104 ASW22K02-104 2NO 2NC O X O X X O X O Knob Lever Key ASW222 ASW2L22 ASW2K22 ASW2122 ASW21L22 ASW21K22 ASW2222 ASW22L22 ASW22K22 2NO 2NC O O X X X X O O Knob Lever Key ASW222-111 ASW2L22-111 ASW2K22-111 ASW2122-111 ASW21L22-111 ASW21K22-111 ASW2222-111 ASW22L22-111 ASW22K22-111

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 714 www.IDEC.com 1904032203 Non-Illuminated Selector Switches (Assembled) continued 3-Position Selector Switches Style Part Number Contact Mounting Operator Position Maintained Spring Return from Right Spring Return from Left Spring Return Two-Way L C R L C R L C R L C R L C R 2NO 1 X O O O O X Knob Lever Key ASW320 ASW3L20 ASW3K20 ASW3120 ASW31L20 ASW31K20 ASW3220 ASW32L20 ASW32K20 ASW3320 ASW33L20 ASW33K20 2NC 1 O X X X X O Knob Lever Key ASW302 ASW3L02 ASW3K02 ASW3102 ASW31L02 ASW31K02 ASW3202 ASW32L02 ASW32K02 ASW3302 ASW33L02 ASW33K02 2NO 2NC X O O X O O X X O X X O Knob Lever Key ASW322 ASW3L22 ASW3K22 ASW3122 ASW31L22 ASW31K22 ASW3222 ASW32L22 ASW32K22 ASW3322 ASW33L22 ASW33K22 2NO 2NC X X O O O X X O X O O X Knob Lever Key ASW322-309 ASW3L22-309 ASW3K22-309 ASW3122-309 ASW31L22-309 ASW31K22-309 ASW3222-309 ASW32L22-309 ASW32K22-309 ASW3322-309 ASW33L22-309 ASW33K22-309 2NO 2NC O O O O X O X O O X O X Knob Lever Key ASW322-310 ASW3L22-310 ASW3K22-310 ASW3122-310 ASW31L22-310 ASW31K22-310 ASW3222-310 ASW32L22-310 ASW32K22-310 ASW3322-310 ASW33L22-310 ASW33K22-310 4NO X O X O O O O O O X O X Knob Lever Key ASW340 ASW3L40 ASW3K40 ASW3140 ASW31L40 ASW31K40 ASW3240 ASW32L40 ASW32K40 ASW3340 ASW33L40 ASW33K40 4NC O X O X X X X X X O X O Knob Lever Key ASW304 ASW3L04 ASW3K04 ASW3104 ASW31L04 ASW31K04 ASW3204 ASW32L04 ASW32K04 ASW3304 ASW33L04 ASW33K04 1. The truth table indicates the operating position of contact block when the operator is switched to that position. X = On (closed contacts) O = Off (open contacts) X X = Overlapping Contacts: Remain on (closed contacts) when switch is moved between these two positions. 2. All knob and lever selector switches come in black. Other colors are available by ordering the knob or lever separately. 3. Every key selector switch uses an identical key. The key is removable in any maintained position. 4. Custom contact configurations are available, see page 720. 4-Position Selector Switch Style Maintained Contact Mounting Operator Position Part Number 1 2 3 4 1 2NO 2NC X O O O O X O O O O X O O O O X Knob Lever ASW422-411 ASW4L22-411 5-Position Selector Switch Style Maintained Contact Mounting Operator Position Part Number 1 2 3 4 5 2 3 4 2NO 2NC X O O O O X O O O O O O O O X O O O O X Knob Lever ASW522-501 ASW5L22-501

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 715 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Non-Illuminated Selector Switches (Sub-Assembled) Contact Blocks + Operator + Knob or Lever* + Color Insert* = Complete Part† 1. *Not needed with key type switches. 2. †Knob type shown. Operators Style Positions Description Part Number Knob/Lever Maintained ASW200 Spring return from right ASW2100 Spring return from left ASW2200 Maintained, Cam 1 Maintained, Cam 2 Maintained, Cam 3 ASW300-1 ASW300-2 ASW300-3 Spring return from right, Cam 1 Spring return from right, Cam 2 ASW3100-1 ASW3100-2 Spring return from left, Cam 1 Spring return from left, Cam 2 ASW3200-1 ASW3200-2 Spring return from left/right, Cam 1 Spring return from left/right, Cam 2 ASW3300-1 ASW3300-2

4 Maintained, Standard Cam

Maintained, Cam 1 ASW400 ASW400-1

5 Maintained, Standard cam

Maintained, Cam 1 ASW500 ASW500-1 Key Maintained ASW2K00 Spring return from right ASW21K00 Spring return from left ASW22K00 Maintained, Cam 1 Maintained, Cam 2 Maintained, Cam 3 ASW3K00-1 ASW3K00-2 ASW3K00-3 Spring return from right, Cam 1 Spring return from right, Cam 2 ASW31K00-1 ASW31K00-2 Spring return from left, Cam 1 Spring return from left, Cam 2 ASW32K00-1 ASW32K00-2 Spring return from left/right, Cam 1 Spring return from left/right, Cam 2 ASW33K00-1 ASW33K00-2 1. Two keys are supplied with every key switch, all are keyed alike, and removable from any maintained position. 2. Locking rings are included with all operators. Order knobs, levers, and color inserts separately. 3. Different cams produce different contact actions. For details, see page 720. 4. Key switch operator supplied with black sleeve. Handles and Inserts Style Part Number Knob ASWHHY-j Lever ASWHHL-j Color Insert TW-HC1-j Contact Blocks Style Contacts 1NO 1NC Finger- Safe Spring-Up Terminal HW-U10-F HW-U01-F HW-U10R-F (early make) HW-U01R-F (late break) Dummy Block HW-DB 1. Push rod color code: Green = NO contact block Red = NC contact block. 2. Dummy blocks (no contacts) are used with an odd number of contact blocks. j Handle/Insert Color Codes Color Code Black* B Blue S Green G Red R Yellow Y White† W *Color inserts not available in black. †Knob and lever not available in white. Replacement Parts Key Switch Black Sleeve AKW2B-B

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 716 www.IDEC.com 1904032203 Illuminated Selector Switches (Assembled) Assembled Illuminated Selector Switches Function SL: Illuminated Selector Switch Series Designation W: TW series Number of Positions 2: 2-Position 3: 3-Position Spring Return Action Blank: Maintained 1: Spring return from Right 2: Spring return from Left 3: Two-Way spring return from Left and Right Illumination Circuit 99: Full Voltage (lamp determines voltage) 126: 120V AC Step Down Transformer 246: 240V AC Step Down Transformer 486: 480V AC Step Down Transformer Lamp Voltage (Full Voltage Units Only) 6V: 6V AC/DC 12V: 12V AC/DC 24V: 24V AC/DC 120V: 120V AC 240V: 240V AC Lens Color Code A: Amber G: Green R: Red S: Blue W: White Y: Yellow Contact Circuit Number Standard circuits are listed on the following pages and 720. Lamp Type D: LED Lamp Contact Arrangement 10: 1NO 01: 1NC 20: 2NO 02: 2NC 40: 4NO 04: 4NC 11: 1NO-1NC 22: 2NO-2NC 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. All transformers step down to 6V (use 6V lamp).

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 717 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Illuminated Selector Switches(Assembled) continued Illuminated 2-Position Selector Switches Style Part Number Contact Mounting Operator Position Lamp Circuit Type Maintained Spring Return from Right Spring Return from Left L R L R L RL R 1NO 1NC O X X O Transformer Full Voltage ASLW2 j 11D-k ASLW29911D-k-l ASLW21 j 11D-k ASLW219911D-k-l ASLW22 j 11D-k ASLW229911D-k-l 2NO 1 O O X X Transformer Full Voltage ASLW2 j 20D-k ASLW29920D-k-l ASLW21 j 20D-k ASLW219920D-k-l ASLW22 j 20D-k ASLW229920D-k-l 2NC 1 X X O O Transformer Full Voltage ASLW2 j 02D-104-k ASLW29902D-104-k-l ASLW21 j 02D-104-k ASLW219902D-104-k-l ASLW22 j 02D-104-k ASLW229902D-104-k-l 2NO 2NC O X O X X O X O Transformer Full Voltage ASLW2 j 22D-k ASLW29922D-k-l ASLW21 j 22D-k ASLW219922D-k-l ASLW22 j 22D-k ASLW229922D-k-l Illuminated 3-Position Selector Switches, Maintained and Spring Return from Right Style Part Number Contact Mounting Operator Position Lamp Circuit Type Maintained Spring Return From Right Spring Return from Left Spring Return Two-Way L C R L C R L C R L C R L C R 2NO 1 X O O O O X Transformer Full Voltage ASLW3 j 20D-k ASLW39920D-k-l ASLW31 j 20D-k ASLW319920D-k-l ASLW32 j 20D-k ASLW329920D-k-l ASLW33 j 20D-k ASLW339920D-k-l 2NC 1 O X X X X O Transformer Full Voltage ASLW3 j 02D-k ASLW39902D-k-l ASLW31 j 02D-k ASLW319902D-k-l ASLW32 j 02D-k ASLW329902D-k-l ASLW33 j 02D-k ASLW339902D-k-l 2NO 2NC X O O X O O X X O X X O Transformer Full Voltage ASLW3 j 22D-k ASLW39922D-k-l ASLW31 j 22D-k ASLW319922D-k-l ASLW32 j 22D-k ASLW329922D-k-l ASLW33 j 22D-k ASLW339922D-k-l 2NO 2NC X X O O O X X O X O O X Transformer Full Voltage ASLW3 j 22D-309-k ASLW39922D-309-k-l ASLW31 j 22D-309-k ASLW319922D-309-k-l ASLW32 j 22D-309-k ASLW329922D-309-k-l ASLW33 j 22D-309-k ASLW339922D-309-k-l 2NO 2NC O O O O X O X O O X O X Transformer Full Voltage ASLW3 j 22D-310-k ASLW39922D-310-k-l ASLW31 j 22D-310-k ASLW319922D-310-k-l ASLW32 j 22D-310- k ASLW329922D-310- k -l ASLW33 j 22D-310-k ASLW339922D-310-k-l 4NO X O X O O O O O O X O X Transformer Full Voltage ASLW3 j 40D-k ASLW39940D-k-l ASLW31 j 40D-k ASLW319940D-k-l ASLW32 j 40D-k ASLW329940D-k-l ASLW33 j 40D-k ASLW339940D-k-l 4NC O X O X X X X X X O X O Transformer Full Voltage ASLW3 j 04D-k ASLW39904D-k-l ASLW31 j 04D-k ASLW319904D-k-l ASLW32 j 04D-k ASLW329904D-k-l ASLW33 j 04D-k ASLW339904D-k-l 1. In place of j, specify the Transformer Voltage Code. 2. In place of k, specify the Lens/LED Color Code. 3. In place of l, specify the Full Voltage Code. 4. For custom contact configurations, see page 720. 5. Light is independent of switch position. 6. Yellow selector switch comes with white LED. l Full Voltage Codes Voltage Code 6V AC/DC 6V 12V AC/DC 12V 24V AC/DC 24V 120V AC 120V 240V AC 240V j Transformer Voltage Codes Voltage Code 120VAC 126 240VAC 246 480VAC 486 Transformers step down to 6V (use 6V LED). k LED/Lens Color Codes Color Code Amber A Green G Red R Blue S White W Yellow Y

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 718 www.IDEC.com 1904032203 Illuminated Selector Switches (Sub-Assembled) Transformer* + Contact Block + Operator + Lamp/Lead Holder† + LED + Lens = Complete Part *Full voltage units use a full voltage adaptor TW-DA1FB (even number of blocks) OR HW-DA1FBN (odd number of blocks) instead of a transformer. †Lamp holder is not included with operators, order separately. Operators Style Positions Description Part Number Maintained ASLW200 Spring return from right ASLW2100 Spring return from left ASLW2200 Maintained, cam 1 Maintained, cam 2 Maintained, cam 3 ASLW300-1 ASLW300-2 ASLW300-3 Spring return from right, cam 1 Spring return from right, cam 2 ASLW3100-1 ASLW3100-2 Spring return from left, cam 1 Spring return from left, cam 2 ASLW3200-1 ASLW3200-2 Spring return from left/right, cam 1 Spring return from left/right, cam 2 ASLW3300-1 ASLW3300-2 Different cams produce different contact action. For details, see Contact Arrangements on page 720. Lenses (Knobs) Style Part Number Knob ASLWLU-k In place of k, specify the lens color code from table. Lamps Style Voltage Part Number LED 6V AC/DC LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 1. In place of k, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. k LED/Lens Color Codes Color Code Amber A Green G Red R Blue S White W Yellow Y Yellow LED not available. Use white LED

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 719 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Illuminated Selector Switches (Sub-Assembled) continued Contact Blocks Style Contacts 1NO 1NC Finger- Safe Spring-Up Terminal HW-U10-F HW-U01-F HW-U10R-F (early make) HW-U01R-F (late break) Dummy Block HW-DB 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function Lamp Circuit Components Style Application Part Number Short Lamp Holder Used with full voltage adaptor and one contact block TW-LH1 Long Lamp Holder Used with Full-size Transformer and two contact blocks TW-LH2 Lead Holder Used with TW-LH2 holder when using four contact blocks and full size transformer HW-LH3 Transformers/Full Voltage Modules Style Description Part Number Full Size Transformer Finger-Safe 120V AC TW-F126B 240V AC TW-F246B 480V AC TW-F486B Dummy Block with Full Voltage Adaptor For use with odd number of contacts. Finger-Safe HW-DA1FBN Full Voltage Adaptor For use with even number of contacts. Finger-Safe TW-DA1FB All Transformers step down to 6V (use 6V lamp).

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 720 www.IDEC.com 1904032203 Contact Arrangement Charts How to Read Contact Arrangement Charts To determine contact block mounting position, first make sure the selector switch is oriented as shown on the right Contact Arrangement Type and quantity of switch contacts Circuit Number * N/D = No designation required Contact Block Mounting Position Position or mounting contact blocks on operator. Operator Position Truth table indicates the operating position of contact block when operator is switched to that position (X - closed, O - open). Contact Block Part Number Part number to use when ordering sub-assembly contact blocks, as required for use with corresponding mounting positionContact Arrangement Chart: 2-Position Selector Switches Style Mounting Position Operator Position Contact Block Part Number Description Operator Part Number Contact Circuit Number Maintained Spring Ret. from Rt. Spring Ret. from Lt. L R L R L R L R 1NO N/D

1 O X HW-U10-F Knob/Lever

1 X O HW-U01-F Knob/Lever

1 O X HW-U10R-F Knob/Lever

1 X O HW-U01R-F Knob/Lever

1 O X HW-U10-F

2 X O HW-U01-F

3 O X HW-U10-F

4 X O HW-U01-F

2 O X HW-U10-F

3 X O HW-U01-F

  1. NO-EM, NC-LB = Early Make, Late Break. N/D = No circuit number designation required in assembled selector switch part number. 2. X = On (closed contacts) O = Off (Open contacts) L R

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 721 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Contact Arrangement Chart: 3-Position Selector Switches Style Mounting Position Operator Position Contact Block Part Number Description Operator Part Number Contact Circuit Number Maintained Spring Return from Right Spring Return from Left Two-Way L C R L C R L C R L C R L C R 1NO 1NC 202

1 X 0 0 HW-U10-F Knob/Lever

ASLW3300-12 X X O HW-U01-F 203 1 0 X X HW-U01-F Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-12 O 0 X HW-U10-F 302

1 X 0 X HW-U10-F Knob/Lever

ASLW3300-22 X X O HW-U01-F 303 1 0 X O HW-U01-F Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-22 O 0 X HW-U10-F 2NO N/D ASLW3300-12 O 0 X HW-U10-F 301 ASLW3300-22 O 0 X HW-U10-F 2NC 304 1 0 X O HW-U01-F Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3300-22 X X O HW-U01-F N/D 1 0 X X HW-U01-F Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3300-12 X X O HW-U01-F 2NO 2NC N/D

1 X 0 0 HW-U10-F

4 X X 0 HW-U01-F

1 X 0 X HW-U10-F

2 X X 0 HW-U01-F

3 X 0 X HW-U10-F

4 X X O HW-U01-F

4 O 0 X HW-U10-F

2 O 0 X HW-U10-F

  1. Each operator sub-assembly is available as a “-1” and a “-2” for 3-position selector switches. The internal cam of a “-1” is different from that of a “-2”. This results in designated combinations of open and closed contacts in the various operator positions. 2. N/D = No circuit number designation required in assembled part number. 3. X = On (closed contacts) O = Off (open contacts). X-X Overlapping contacts remain on (closed) when switch is moved between these two positions.

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 722 www.IDEC.com 1904032203 Contact Arrangement Chart: 3-Position Selector Switches Style Mounting Position Operator Position Contact Block Part Number Description Operator Part Number Contact Circuit Number Maintained Spring Return from Right Spring Return from Left Two-Way L C R L C R L C R L C R L C R 4NO N/D

3 X 0 0 HW-U10-F

  1. Each operator sub-assembly is available as a “-1” and a “-2” for 3-position selector switches. The internal cam of a “-1” is different from that of a “-2”. This results in designated combinations of open and closed contacts in the various operator positions. 2. N/D = No circuit number designation required in assembled part number. 3. X = On (closed contacts) O = Off (open contacts). X-X Overlapping contacts remain on (closed) when switch is moved between these two positions.

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 723 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Custom Selector Switch Building Guide To build a custom selector switch, follow these steps. Step 1 How many positions of the switch are needed? # of positions (2, 3, 4, 5) Step 2 How many contacts should there be? # of isolated contacts (maximum 6) Step 3 Fill in the Truth Table (X = closed, 0 = open) Knob Position 1 2 3 4 5 Contacts Step 4 If building a 2 position selector, skip this step. (2 position selectors have only one cam) If building a 3, 4, or 5 position selector, determine appropriate cam as follows:

  • Look at Row 1 from above table and locate an identical row in the operator truth tables (See next page).
  • Repeat for all rows. The user must find one operator that contains all rows from above table.
  • Record the operator cam version. Step 5 Build by placing appropriate contact in appropriate mounting position for each desired row on operator cam truth table. “L” and “R” refer to mounting on left or right side of operator as viewed from the front of the panel. Step 6 Develop an assembly part number (if necessary) as follows: follow standard numbering nomenclature for selector switches (see pages 712 or 716. In place of the “Circuit Number” indicate the cam number and contact arrangement as such ASW322-3-OELCSS, where “3” is the cam number, and contact arrangement “OELCXX” calls out individual contact mounting locations in order (see diagram above). O=NO, C=NC, E=NO-EM, L=NC-LB, X= no contact. Part number must designate all 6 pos- sible mounting locations. Caution: Before putting any custom selector switch into use, the user should use an ohmmeter to test for desired performance. 1. For Operator Truth Tables, see next page. L Mounting Positions R

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 724 www.IDEC.com 1904032203 Operator T ruth T ables Use the following tables to build custom selector switches.

2 Position Selector Switches

(NO) L O X R O X HW-U01-F (NC) L X O R X O HW-U10R-F (NO-EM) L O X R O X HW-U01R-F (NC-LB) L X O R X O

3 Position Selector Switches

(NO) L X O O R O O X HW-U01-F (NC) L O X X R X X O HW-U10R-F (NO-EM) L X O O R O O X HW-U01R-F (NC-LB) L O X X R X X O Contact Mounting Position Operator Position Left Center Right ASW300-2 ASW3K00-2 ASLW300-2 HW-U10-F (NO) L X O X R O O X HW-U01-F (NC) L O X O R X X O HW-U10R-F (NO-EM) L X O X R O O X HW-U01R-F (NC-LB) L O X O R X X O Contact Mounting Position Operator Position Left Center Right ASW300-3 ASW3K00-3 ASLW300-3 HW-U10-F (NO) L X O O R O O X HW-U01-F (NC) L O X O R O X O HW-U10R-F (NO-EM) L X O X R X O X HW-U01R-F (NC-LB) L O X X R X X O

4 Position Selector Switches

(NO) L X O O O R O X O O HW-U01-F (NC) L O X X X R X O X X HW-U10R-F (NO-EM) L X O O O R O X O O HW-U01R-F (NC-LB) L O X X X R X O X X Contact Mounting Position Operator Position 1 2 3 4 ASW400-1 HW-U10-F (NO) L X O O O R O O O X HW-U01-F (NC) L O O X O R O X O O HW-U10R-F (NO-EM) L X X O X R X O X X HW-U01R-F (NC-LB) L O X X X R X X X O

5 Position Selector Switches

(NO) L X O O O O R O X O O O HW-U01-F (NC) L O O X X X R O O O X X HW-U10R-F (NO-EM) L X O O O O R O X O O O HW-U01R-F (NC-LB) L O X X X X R X O X X X Contact Mounting Position Operator Position 1 2 3 4 5 ASW500-1 HW-U10-F (NO) L X O O O O R O O O O X HW-U01-F (NC) L O O O X O R O X O O O HW-U10R-F (NO-EM) L X X X O X R X O X X X HW-U01R-F (NC-LB) L O X X X X R X X X X O

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 725 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Nameplates — TW Series Faceplates NWAL NWAQL NWAS EMERGENCY STOP 1.13" (29mm) 1.0" (25.4mm) 1.13" (29mm) 0.975" (25mm) 0.566" (14.5mm) 1.76" (45mm) 1.76" (45mm) ø70mm Part Number Nameplate (blank) NWAL-OB (black) NWAL-OR (red) NWAQL-OB (black) NWAQL-OR (red) NWAS-OB NWAR-O Nameplate (engraved) NWAL-j NWAQL-j NWAS-j NWAR-27† 1. In place of j, insert either the Standard Legend Code from table below or custom engraving delimited by “ “. 2. Standard engravings are available at no charge. 3 NWAR-27 comes marked “Emergency Stop” as shown in drawing. Standard Legend Codes Pushbuttons Pushbuttons/Selector Switches Selector Switches Legend Code Legend Code Legend Code Legend Code Legend Code AUTO CLOSE DOWN EMERG.STOP FAST FORWARD HAND HIGH IN INCH JOG LOW LOWER OFF ON 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 OPEN OUT RAISE RESET REVERSE RUN SLOW START STOP STOP TEST UP I (Int’l On) O (Int’l Off) EMO 116 117 118 119 120 121 122 123 124 125 126 127 150 151 152 AUTO-MAN CLOSE-OPEN DOWN-UP FAST-SLOW FOR-REV HAND-AUTO HIGH-LOW JOG-RUN LEFT-RIGHT LOWER-RAISE MAN-AUTO OFF-ON ON-OFF OPEN-CLOSE RAISE-LOWER 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 REV-FOR RUN-JOG RUN-SAFE SAFE-RUN SLOW-FAST START-STOP STOP-START UP-DOWN 216 217 218 219 220 221 222 223 AUTO-MAN-OFF AUTO-OFF-MAN CLOSE-OFF-OPEN DOWN-OFF-SLOW FAST-OFF-SLOW FOR-OFF-REV LEFT-OFF-RIGHT LOWER-OFF-RAISE OFF-MAN-AUTO OFF-SLOW-FAST OFF-1-2 OPEN-OFF-CLOSE SLOW-OFF-FAST SUMMER-OFF-WINTER UP-OFF-DOWN 1-OFF-2 HAND-OFF-AUTO 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 1. To order engraved nameplates, add legend code to nameplate part number. Character height based on the number of characters and size of nameplate. Standard character size is 3/16”. 2. Nameplates with standard legends are the same list price as blank nameplates. Nameplate Order Form on next page.

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 726 www.IDEC.com 1904032203 Custom Engraved Nameplates Order Form — TW Series Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired. To ensure engraving accuracy, fax it to your IDEC representative. or Distributor. NWAL Engraving Location Step 1. Choose Letter Size - 7/64” or 1/8”. Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8” size letters cannot exceed 9 characters. Step 2. Specify Quantity. Qty Enter the number of nameplates desired in the box on the right. 7/64” Letter Size 11 characters max (for 7/64” size letters) Sample Letter Sizes 7/64” Letters: 1/8” Letters: 1/8” Letter Size 9 characters max (for 1/8” size letters) 1 2 3 4 5 6 7 8 9 10 11 NWAQL Engraving Location Step 1. Choose Letter Size - 7/64” or 1/8”. Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8” size letters cannot exceed 9 characters. Step 2. Specify Quantity. Qty Enter the number of nameplates desired in the box on the right. 7/64” Letter Size 11 characters max (for 7/64” size letters) Sample Letter Sizes 7/64” Letters: 1/8” Letters: 1/8” Letter Size 9 characters max (for 1/8” size letters) 1 2 3 4 5 6 7 8 9 10 11 NWAS Engraving Location A Engraving Location B Step 1. Choose Letter Size - 1/8” or 3/32”. Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8” size letters cannot exceed 14 characters. 3/32” Letter Size 20 characters max (for 3/32” size letters) 1/8” Letter Size 14 characters max (for 1/8” size letters) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Step 2. Specify Quantity. Qty Enter the number of nameplates desired in the box on the right. Step 3. Specify Location. Location Enter the location of engraving (A or B), in the box on the right. Sample Letter Sizes 3/32” Letters: 1/8” Letters:

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 727 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Switch Engraving Order Form – TW Series Copy this order form and use it to specify Letter Height, Maximum Number of Lines and Text to be engraved. To ensure engraving accuracy, fax it to your IDEC representative or Distributor. Your Company: Telephone: Name: Fax: Address: Email: PO: Part Number to be Engraved: Please check one of the boxes below to indicate your choice of engraving options: Square Switch Round Switch ø29mm, ø40mm Mushroom Head Engraving Area 1 Engraving Area 2† # of Lines Letter Height Max. Characters Per Line # of Lines Letter Height Max. Characters Per Line # of Lines Letter Height Max. Characters Per Line 5/32 6 5/32 5 Engraving Area 1 1 5/32 5 1/8 6 1/8 6 1/8 5 5/32 6 5/32 5 Engraving Area 2 1 5/32 7 1/8 5 1/8 6 1/8 7 3 1/8 6 3 1/8 5 4 3/32 5 4 3/32 5 1. Above mentioned specifications hold true for standard size pushbuttons (round and square). 2. †Engraving Area 2 can be engraved for 40mm mushroom Head non-Illuminated push button only. 3. Engraving is done on the button itself for non-Illuminated push buttons and on marking plate for illuminated push buttons and pilot lights. 4. Please enter text exactly how you want it engraved, take care to emphasize capital or small letters. Enter text to be engraved: Line 1: Line 2: Line 3: Line 4: Sample Letter Sizes 1/8 Letters: 5/32 Letters: For IDEC Internal Use Only: Work Order #:

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 728 www.IDEC.com 1904032203 Accessories TW Series Accessories Item Appearance Description/Usage Part Number Lamp Removal Tool Rubber tool used to install or remove LED’s OR-55 Contact Block Remover Used to remove contact blocks, transformers, lenses, and adaptors. Can also be used to determine panel thickness adjustment. TW-KC1 Nut Locking Wrench Used in OR-14 locking wrench to tighten locking nuts inside square bezel TW-KQ2 Metal Bezel Chrome plated bezels tighten onto operator (replacement for damaged bezels) Standard octagonal units (chrome-pl.) AW-R8 Full shroud octagonal units (chrome-pl.) AW-RF8 Full shroud mushroom head units Ø 40mm AW-G4 Plastic Bezel Black plastic bezels for square buttons (replacement for damaged bezels) Round flush units (black plastic) AW-RP1B Round extended units (black plastic) AW-FP1B Square units (black plastic) AW-Q1B Square units with full shroud (black plastic) AW-QF1B Boot/Cover Used to cover and protect pushbuttons Waterproof lens cover for square pilot lights APW00LN Waterproof lens cover for square illuminated buttons APW00L Clear boot for round flush units OC-31 Clear boot for round extended units OC-32 *In place of asterisk, specify Rubber Boot color: B (black), G (green), R (red), Y (yellow) - (nitril rubber) OCW-11* Anti-Rotation Ring Ring to prevent operator base from rotating in the mounting hole. Used when nameplate is not used OGL-31 Mounting Hole Plug Black rubber plug fills unused mounting holes in panel. OB-31 Metallic Mounting Hole Plug For plugging unused mounting holes in the panel. Tighten the attached locking ring to a torque of 12 kfg-cm maximum Degree of protection: IP66 LW9Z-BM Replacement Keys Replacement keys (#0) TW-SK Replacement Black Sleeve for Keyswitch AKW2B-B

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 729 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Item Appearance Description/Usage Part Number Metal Button Guard Used on flush buttons to prevent inadvertent actuation OLW-C Terminal Tab Adaptor Quick- connect terminals #250 (17/64” x 3/64”) single tab TW-FA4 Lock-out Adaptor Used to provide lock-out protection for pushbuttons and knob selector switches:

  • Up to Ø 40mm mushroom head size (Padlock not included.) Not applicable for e-stops. HW9Z-KL1 22mm to 30mm Adaptor Used to mount TW series control unit (except square units) Ø 7/8” (22mm) into a Ø 1-13/64” (30mm) panel cut-out. TWN-A1R8 Contact Blocks (with side entry) These contacts are applicable for wires terminated by ring, fork, not recommended for bare wire connections . 1NC 1NO HW-U01 HW-U01-MAU HW-U01R HW-U01R-MAU (with side entry) HW-U10 HW-U10-MAU HW-U10R HW-U10R-MAU (with side entry) Contact Blocks (without side entry) These contacts are applicable for wires terminated by ring, fork, or ferule terminals, and also bare wire connections. HW-U01-F HW-U01-MAU-F HW-U01R-F HW-U01R-MAU-F (no side entry) HW-U10-F HW-U10-MAU-F HW-U10R-F HW-U10R-MAU-F (no side entry)

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 730 www.IDEC.com 1904032203 Dimensions Pushbuttons Flush Extended Extended with Full Shroud 69.4 (3 or 4 blocks) 41.4 49.4 (1 or 2 blocks) ø29 Safety Lever Lock Locking Ring Panel Thickness 0.8 to 6 26.5 29.4 29.6 ø 23.6 LOCK 41.4 ø29 Panel Thickness 0.8 to 6 Locking Ring Safety Lever Lock 49.4 (1 or 2 blocks) 69.4 (3 or 4 blocks) 26.5 29.4 /box229.6 ø 23.6 LOC K LOC K 26.5 41.4 29.4 ø23.518.549.4 (1 block) 69.4 (2 or 3 blocks) 89.4 (4 blocks) Safety Lever Lock Locking Ring Panel Thickness 0.8 to 6 29mm Mushroom 40mm Mushroom Mushroom with Full Shroud 26.5 29.4 LOCK 41.4 23.2 ø2 9 69.4 (2 or 3 blocks) 49.4 (1 block) Safety Lever Lock Locking Ring Panel Thickness 0.8 to 6 89.4 (4 blocks) 26.5 29.4 LOC K 41.4 23.2 ø 40 69.4 (2 or 3 blocks) 49.4 (1 block) Safety Lever Lock Locking Ring Panel Thickness 0.8 to 6 89.4 (4 blocks) ø40 41.4 29.6 ø46 49.4 (1-2 blocks) 69.4 (3-4 blocks) Panel thickness 1 to 6Adust ring 29mm Push-Lock-Turn-Reset 40mm Push-Lock-Turn-Reset Keylock Push On/Off Reset angle 75° 41.4 29.622.5 ø29 49.4 (1-2 blocks) 69.4 (3-4 blocks) Panel thickness 1 to 6Adust ring 41.4 29.6 22.5 ø40 Panel thickness 1 to 6 Reset angle 75°Adjust ring 49.4 (1-2 blocks) 69.4 (3-4 blocks) 41.4 29.624.5 45°47 ø29 Panel thickness 1 to 6Adjust ring Reset (unlock) 49.4 (1-2 blocks) 69.4 (3-4 blocks) 40mm Pushlock Key reset 40mm Push-Pull Square Flush 41.4 29.6 24.5 ø40 45° Panel thickness 1 to 6Adjust ring Reset (unlock) 49.4 (1-2 blocks) 69.4 (3-4 blocks) 41.4 29.6 30.5 ø40 Panel thickness 1 to 6Adjust ring 49.4 (1-2 blocks) 26.5 29.4 /box224.6 /box229.6 LOCK 41.4 49.4 (1 block) 69.4 (2, 3 blocks) 89.4 (4 blocks) Safety Lever Lock Locking Ring Panel Thickness 0.8 to 6 Square Extended 26.5 41.4 29.4 13 /box224.8 /box229.6 LOC K Panel Thickness 0.8 to 6 Locking Ring Safety Lever Lock 49.4 (1 or 2 blocks) 69.4 (3 or 4 blocks) Selector Switches ø29 49.4 (1-2 blocks) 69.4 (3-4 blocks) 41.4 29.625 ø23.4 Panel thickness 1 to 6Adust ring ø29 41.4 29.6 25 25 49.4 (1-2 blocks) 69.4 (3-4 blocks) Panel thickness 1 to 6Adust ring ø29 41.4 29.6 ø23.649.4 (1-2 blocks) 69.4 (3-4 blocks) Panel thickness 1 to 6Adust ring

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 731 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Dimensions continued Illuminated Pushbuttons Extended Extended with Full Shroud Square Extended Marking plate: ø15.5mm Panel Thickness 1 to 6 19 30 ø24 ø29 Marking plate: ø15.5mm Panel Thickness 1 to 6 ø24 ø29 20 30 Marking plate: 21mm Panel Thickness 1 to 6 29mm Push-Turn-Reset 40mm Push-Turn-Reset Mushroom Marking plate: ø13.9mm Reset Angle: 75Panel Thickness 1 to 6 22.5 ø29 Marking plate: ø13.9mm Reset Angle 75 22.5 ø40 Panel Thickness 1 to 6 Marking plate: ø13.9mm ø29 22.5 Panel Thickness 1 to 6 Push-Pull Marking plate: ø13.9mm Panel Thickness 1 to 6 ø40 30.5 Illuminated Selector Switches

1 Contact Block with Full Voltage Adaptor Transformer (2 blocks)

M3.5 Terminal Screws Panel Thickness 1 to 6 86.5

2 Contact Blocks with Full Voltage Adaptor Transformer (4 blocks)

63.5 M3.5 Terminal Screw Panel Thickness 1 to 6mm 106.5 M3.5 Terminal Screws Panel Thickness 1 to 6

3 Contact Blocks with Full Voltage Adaptor 4 Contact Blocks with Full Voltage Adaptor

68.5 M3.5 Terminal Screws Panel Thickness 1 to 6 X1

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 732 www.IDEC.com 1904032203 Dimensions continued Pilot Lights Round Flush APW1 Full Voltage Round Flush APW1 Transformer 29.6 ø29 17.2 28.5 34.3 ø23.6 Terminal cover APS-PVL (supplied) Panel thickness 1 to 6 ø29 17.259.5 20.7 29.6 ø23.6 M3.5 Terminal Screws T transformer Panel thickness 1 to 6 Round Flush Marking Type APW1B Full Voltage Round Flush Marking Type APW1B Transformer ɹ ø29 17.269.5 20.7 29.6 ø23.6 Panel thickness 1 to 6M3.5 Terminal Screws ɹ ø29 17.269.5 20.7 29.6 ø23.6 Panel thickness 1 to 6M3.5 Terminal Screws Dome APW2 Full Voltage Dome APW2 Transformer 29.6 ø29 24.5 28.5 34.3 ø23.6 Terminal Cover APS-PVL (supplied) Panel thickness 1 to 6 ø29 24.559.5 20.7 29.6 ø23.6 M3.5 Terminal Screws T transformer Panel thickness 1 to 6 Square Flush Marking Type APQW1B Full Voltage Square Flush Marking Type APQW1B Transformer 29.6 ɹ 13.1 29.6 28.5 34.3 24.7 Panel thickness 1 to 6 Terminal cover APS-PVL (supplied) 13.1 1669.5 29.6 ˘29.6 28.5 M3.5 Terminal Screws 24.7 Panel thickness 1 to 6 Illuminated Selector Switches 49.4 (1 block) 69.4 (2-3 blocks) 41.4 29.689.4 (4blocks) ø29 ø23.4 Panel thickness 1 to 6Adust ring

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 733 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Dimensions continued Panel Cut-Out Diagram Part Dimension (45 min.) R0.8 max. +0.4 +0.4 +0.2 30 (*1) ø22.3 3.2 24.1 Pushbuttons • The minimum mounting centers are applicable to switches with one layer of contact blocks (one to two contact blocks). When two layers of contact blocks are mounted, determine the minimum mounting centers in consideration of convenience for wiring. 1*) ø40 mm mushroom button type: 40 mm minimum 1*) 2-position, 3-position lever selector switch: 39 mm minimum 1*) 4-position, 5-position lever selector switch: 50 mm minimum

  • When high temperature is expected, take necessary measures such as securing sufficient mounting centers or using a cooling fan.
  • The 3.2 +0.2 0 mm recess is for preventing rotation and is not necessary when the nameplate or anti-rotation ring is not used. All dimensions in mm. Pilot Light Illuminated Pushbuttons Selector Switches Illuminated Selector Switches 1.The Ø 0.137” (Ø 3.5mm) recess is necessary when either the nameplate or anti-rotation ring is used. 2. *>1.404” (36mm) for 2- or 3-position. >1.95” (50mm) for 4- or 5-position. Accessory Dimensions OGL-31 Anti-Rotation Ring OLW-C Metal Button Guard OCW-11 Pushbutton Rubber Boot OB-31 Mounting Hole Rubber Plug ø22 ø27.4 10.2 0.8 ø22.5 18.6 1.6t R42.5 Mounting Centers 50 min. Flush M22 P1.0 ø31 18.5 ø32 Extended M22 Button installed Button installed P1.0 ø32 ø26 ø31 ø29 ø25 3.53.5 HW9Z-KL1 Lock-out Adaptor AW-RP1B Round Plastic Bezel AW-FP1B Round Plastic w/Full Shroud Key hole ø8 Waterproof Rubber Gasket 0.5t ø50 (ID: ø44.4) 29.5 R66.5 Panel Thickness 0.8 to 3.2 82.5 ø22.2 24 (inside) ø29 ø29 19.8 AW-QF1B Square Full Shroud Finger-Safe Cover Dimensions APS-PVL Ø7.0 22.8 7.215.5 39.1

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 734 www.IDEC.com 1904032203 Component Construction and General Instructions — TW Series Instructions for Switches and Pilot Devices TW Series: Adjustment for Panel Thickness The panel thickness ring provides adjustment from 0.04” to 0.24” (1 to 6mm) in 0.004” (0.1mm) increments. Rotate the ring until the markings around the periphery are aligned for the desired thickness, as shown below. Scale on Adjustment (in 0.1 mm) 0.1 mm 1 mm Panel Thickness Scale (in 1 mm on the operator) A 5 4 3 5 4 6 6 Ex. Panel thickness 2 mm Ex. Panel thickness 2.6 mm Note: When a nameplate or an anti-rotation ring is used, add 0.03” (0.8mm) to the panel thickness dimension. An adjustment for panel thicknesses shown below can be made quickly by using the contact block remover tool. 1.6mm 2.3mm 3.5mm 1mm 2mm 3.2mm Contact Block Removal Tool Panel Thickness Adjustment Ring Contact Block Removal Tool (TW-KC1) Bezel Option: Nameplate Operator Waterproof Lens (Round lens used on square pushbuttons and pilot lights only) , Base Contact Block Full Voltage Adaptor: Full Size Transformer: Options Lead Holder Lamp Holder LED Adjustment Ring Panel Thickness Waterproof Gasket (Panel) Lens or Button

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers 735 800-262-IDEC (4332) • USA & Canada ø22mm - TW Series Switches & Pilot Devices 1904032203 Instructions continued Pilot Lights and Pushbuttons IMPORTANT: Install the body of the TW control unit with the panel thickness scale facing up. Octagonal and Round Bezels Octagonal and round bezels screw into the operator. Use a locking ring wrench (optional) for secure tightening and easy removal. Round flush and extended buttons snap onto the operator base. Mushroom buttons screw onto the operator base. Every round lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be printed and placed in the lens. Round Marking Unit Insert marking plate under lens Lens Marking Plate Press in Press in round flush and extended lens. Screw in mushroom lens Square Bezels Square bezels are installed in a 3-step procedure. First install the base plate from the front. Then install the lock nut using the nut locking wrench (optional). Finally, install the square bezel, which snap-fits onto the base plate. Square buttons also snap onto the operator base. Every square lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be printed and placed in the lens. Square units include a round waterproof lens which screws into the operator. The square outer lens snaps on. Square Marking Units Insert marking plate under lens Pilot Light Marking Plate Insert Square Lens Insert marking plate under lens Illuminated Pushbutton Marking Plate Lens Retainer Waterproof Lens Press in Square Lens To remove square lens from operator, place a screwdriver under the indentation on the side of the lens. To remove the marking plate, place a screwdriver under the indentation and lift out the plate. The lens retainer can be removed by pressing a 3/16” screwdriver into one of the recesses. Marking Plate Engraving Area Shape Engraving Area Used With Part Number Round Ø 0.55” (14mm) Illuminated pushbuttons ALW2B Ø 0.55” (14mm) Pilot lights APW2B Mushroom Ø 0.55” (14mm) Illuminated mushroom ALW3B Square q 0.83” (21mm) Square pilot lights APQW1B Square q 0.83” (21mm) Square illuminated pushbuttons ALQW2B

Switches & Pilot DevicesSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers ø22mm - TW Series Switches & Pilot Devices 736 www.IDEC.com 1904032203 Instructions, continued Selector Switches The operator shaft of each unit has a recess to identify in which direction to install the handle. Align the handle with the recess. Press color insert (TW-HC1) into the handle and then press handle into the operator, as shown below. Selector Switch (non-illuminated) Illuminated Selector Switch Recess Press in color insert Press in handle Remove color insert before pulling out the handle. Standard Operating Positions 2-Postion, 90º 3-Postion, 45º 4-Postion, 45º 5-Postion, 30º 1 2 12 0 1 2 3 4 Positions: Non-Illuminated 3-Position Operators 0 1 Installation of LED Illuminated Units Transformers are recommended for use in areas subjected to inductive noise. When using full voltage types, install a protection diode as shown below. (Diode with DC power supply to protect against surges and noise.) Terminal Terminal Diode LED