AFM XPPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

  • Energy Efficiency Level V
  • C EC 2008 & EISA2007 C om pliant
  • IT & M edical Approvals
  • C hina C om pulsory C ertification (C C C ) Q ualified
  • O ptional C lass II Versions
  • O ptional W hite C ase Versions
  • 3 Year W arranty AFM Series Input Input Voltage • 8 0-2 6 4 VAC, derate output pow er 2 5 % <90 VAC Input Frequency • 47-6 3 H z Input C urrent • AFM 30: 0.8 A rm s at 115 VAC, AFM 45 : 1.2 A rm s at 115 VAC, AFM 6 0: 1.5 A rm s at 115 VAC Inrush C urrent • AFM 30: 5 0 A m ax at 2 40VAC, AFM 45 : 5 0 A m ax at 2 40VAC, AFM 6 0: 12 0 A m ax at 2 40VAC Pow er Factor • EN 6 1000-3-2 , class A Earth Leakage C urrent • 15 0 µA m ax at 2 6 4 VAC/6 0 H z N o Load Input Pow er • AFM 30/45 : <0.3 W , AFM 6 0: <0.5 W Output O utput Voltage • See table O utput Voltage Trim • N ot user-adjustable Initial Set Accuracy • ±2 % M inim um Load • N o m inim um load required Start U p D elay • 3 s m ax at 115 VAC H old U p Tim e • 8 m s m inim um at 115 VAC Line R egulation • ±1.0% m axim um Load R egulation • 2 .5 % m axim um Transient R esponse • 4% m ax. deviation, recovery to w ithin 1% in 5 00 µs for a 2 5 % load change R ipple & N oise • 1% m ax pk-pk (1) O vervoltage Protection • 110-170% Vnom , recycle input to reset O verload Protection • AFM 45 /6 0: 110-170% , AFM 30: 110-2 2 0% , auto recovery Short C ircuit Protection • T rip and restart (hiccup m ode) Tem perature • 0.04% /°C C oefficient xppow er.com General Efficiency • See table Energy Efficiency • Level V Isolation • 4000 VAC Input to O utput, 2 x M O PP 15 00 VAC Input to G round, 1 x M O PP* O utput 0 V is electrically connected to Input G round*. *N ot C8 version. Sw itching Frequency • 30/45 W : 5 8 kH z typ., 6 0 W : 5 2 kH z typ. Pow er D ensity • AFM 30: 2 .8 W /In 3, AFM 45 : 4.2 W /In 3, AFM 6 0: 3.76 W /In 3 M TB F • > 2 5 0 kH rs to M IL-H D B K-2 17F at 2 5 °C, G B , full load Environmental O perating Tem perature • 0 °C to +6 0 °C, derate from 100% pow er at +40 °C to 6 0% pow er at +6 0 °C O perating H um idity • 10-95 % R H , non-condensing Storage Tem perature • -40 °C to +8 0 °C O perating Altitude • 2 000 m Shock • 30 g, 10 m s on 3 axes Vibration • 5 -100 H z, 2 .31 m /s 2 , 2 0 m ins, 3 axes EMC & Safety Em issions • EN 5 5 011/2 2 /FCC Class B conducted, EN 5 5 011/2 2 /FCC Class B radiated H arm onic C urrents • EN 6 1000-3-2 , Class A Voltage Flicker • EN 6 1000-3-3 ESD Im m unity • EN 6 1000-4-2 , 6 kV contact and 8 kV air discharge R adiated Im m unity • EN 6 1000-4-3, 3 V/m Perf Criteria A EFT/B urst • EN 6 1000-4-4, level 3 Perf Criteria A (7) Surge • EN 6 1000-4-5 , installation class 3 Perf Criteria A C onducted Im m unity • EN 6 1000-4-6 , 3 Vrm s Perf Criteria A M agnetic Field • EN 6 1000-4-8 , 3 A/m , Perf Criteria A D ips & Interruptions • EN 6 1000-4-11, 30% for 10 m s, 6 0% 100 m s, 100% 5 000 m s, Perf Criteria A, B , B EN 6 06 01-1-2 , 30% 5 00 m s, 6 0% 100 m s, 100% 10 m s, 100% 5 000 m s, Perf A, A, A, B (8 ) Safety Approvals • EN 6 095 0-1, U L6 095 0-1, IEC6 095 0-1 EN 6 06 01-1 (3rd Ed.), U L6 06 01-1 (2 nd Ed.), IEC6 06 01-1 (3rd Ed.) China Com pulsory Certification (CCC) Q ualified.
  1. Ripple and noise m easured at 20 M H z bandw idth w ith a 10 µF tantalum and 0 .1 µF ceram ic cap connected at the m easurem ent point. 2. T otal regulation includes initial set accuracy, line and load regulation. 3. For optional C lass II versions w ith a polarised IEC 320 -C 8 inlet, add suffix ‘C 2’ to the m odel num ber, e.g. AFM 60 U S24C 2. 4. For alternative IEC 320 -C 6 inlet, add suffix ‘C 6’ to the m odel num ber eg. AFM 60 U S24C 6. 5. For w hite case version add suffix -W . M O Q applies, contact sales for details. 6. O ther output voltages are available, contact sales for details. 7 . M inim um average of efficiencies m easured at 25% , 50 % , 7 5% & 10 0 % load. 8 . A m inim um load of 1% is required to m eet perform ance criteria A. 9. Perform ance criteria given for high line input. 0.17 (4.4) 0.68 (17.3) 0.07 (1.8) 0.66 (16.8) B 0.53 (13.7) 80º 1.41 (36.0) C A 37.4 ±2 (950 ±50) Output Plug: ø 5.5 x ø 2.5 x 11.0 mm inner positive LED Indicator Optional AC Cable Restraint (see note 8 below) 1.31 (33.4) Standard AC INLET IEC-320-C14 Optional C8P AC INLET IEC-320-C8P Optional C6 AC INLET IEC-320-C6 1. All dim ensions show n in inches (m m ). T olerance is 0.02 (0.5 ) m axim um , except output cable length. 2 . W eight: AFM 45 : 0.5 6 lbs (2 5 6 g), AFM 6 0: 0.78 lbs (36 0 g) approx. 3. Case m aterial is PC Class 94 V-0. 4. O utput Lead: U L118 5 , 16 AW G 5 . For European m ains lead order part EU -M AIN S-IEC for C14 versions, EU -M AIN S-5 for C6 versions or EU -M AIN S-8 for C8 versions. 6 . For U K m ains lead order part U K-M AIN S-IEC for C14 versions, U K-M AIN S-5 for C6 versions or U K-M AIN S-8 for C8 versions. 7 . For U S m ains lead order part U S-M AIN S-IEC for C14 versions, U S-M AIN S-5 for C6 versions or U S-M AIN S-8 for C8 versions. 8 . For optional AC Cable R estraint on the standard input version add suffix ‘ ‘A’ to the m odel num ber e.g. AFM 6 0U S2 4A. AC M ains Lead m ust be Interpow er Corporation, part num ber 70006 02 0300. O ption AC Cable R estraint is not available on IEC32 0-C6 inlet or Class II versions. 9. The standard C7 cable fits the C8 P connector. O utput Pow er O utput Voltage (6) O utput C urrent Efficiency (7) M odel N um ber (3 ,4,5) 30 W 12 V 2 .5 0 A 8 7 .9% AFM 30U S12 30 W 15 V 2 .00 A 8 8 .4% AFM 30U S15 30 W 18 V 1.6 7 A 8 7 .6 % AFM 30U S18 30 W 2 4 V 1.2 5 A 8 8 .0% AFM 30U S2 4 48 W 12 V 4.00 A 8 7 .7% AFM 45 U S12 48 W 15 V 3.2 0 A 8 8 .0% AFM 45 U S15 48 W 18 V 2 .6 7 A 8 7 .2 % AFM 45 U S18 48 W 2 4 V 2 .00 A 8 7 .7% AFM 45 U S2 4 6 0 W 12 V 5 .00 A 8 7 .3% AFM 6 0U S12 6 0 W 15 V 4.00 A 8 8 .2 % AFM 6 0U S15 6 0 W 18 V 3.34 A 8 8 .3% AFM 6 0U S18 6 0 W 2 4 V 2 .5 0 A 8 7 .8 % AFM 6 0U S2 4 Notes AFM 3 0 & 45 AFM 60