  • Universal Input 90-264 VAC
  • Continous Short Circuit Protection
  • EN550022 Class B
  • Low Cost
  • 6, 15 and 25 Watt Versions
  • Non-standard Outputs Available
  • 3 Year Warranty AEP Series Input Input Voltage • 90-264 VAC Input Frequency • 47-63 Hz Input Current • 0.5/0.25 A max at 115/230 VAC (6 W & 15 W) 0.7/0.3 A at 115/230 VAC (25 W) Inrush Current • 15/30 A max at 115/230 VAC (6 W) 25/50 A max at 115/230 VAC (15 W & 25 W) Power Factor • Meets EN61000-3-2, Class A Output Output Voltage • See tables Initial Set Accuracy• See tables Minimum Load • No minimum load requirement Start Up Delay • 6 W 100 ms,

15 W 270 ms,

25 W 280 ms

Hold Up Time • 10 ms typical at 115 VAC, 60 ms typical at 230 VAC Line Regulation • See tables Load Regulation • See tables Ripple & Noise • 1 % pk-pk max (see note 2) Overvoltage Protection• 125% typical Overload Protection • Trip and restart (Hiccup mode) Short Circuit Protection• Constant current (6 W) Continuous (auto recovery) (15 W & 25 W) Temp. Coefficient • ±0.05%/° C xppower.com General Efficiency • Typically 67% for 6 W, 75% for 15 W, 80% for 25 W Isolation • 3000 VAC Input to Output Switching Frequency • 30-200 kHz (6 W) 30-35 kHz typical (15 W & 25 W) Power Density • 0.75 W/in3 (6W), 1.87 W/in3 (15 W)

1.88 W/in3 (25 W)

MTBF • >200 kHrs to MIL-HDBK-217F at 25 ° C, GB Environmental Operating Temperature• 0 ° C to +60 ° C, derate linearly from +40 ° C at 100% load to 60% load at +60 ° C (6 W & AEP15 5 V-13.6 V), 50% load at 60 ° C (25 W & AEP15 15 V-24 V) Storage Temperature • -20 ˚ C to +85 ˚ C Operating Humidity • 93% RH, non-condensing Operating Altitude • 2000 m EMC & Safety Emissions • EN55022 Class B conducted and radiated Harmonic Currents • EN61000-3-2 Class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, level 2 Perf Criteria B Radiated Immunity • EN61000-4-3, level 2 Perf Criteria A EFT/Burst • EN61000-4-4, level 2 Perf Criteria B Surge • EN61000-4-5, Installation Class 2, Perf Criteria B Conducted Immunity • EN61000-4-6, level 2 Perf Criteria B Dips & Interruptions• EN61000-4-11, 5 % U T 10 ms, Perf Criteria B, 70 % UT 500 ms, Perf Criteria C Safety Approvals • EN60950, UL1950, CSA C22.2 No.234 cUL AC-DC

  1. Initial set accuracy is at 60% full load. 2. Add a 0.1µF E.L capacitor to output for ripple & noise measurement at 20 MHz BW. 3. Line regulation measured from 100 VAC to 240 VAC, full load. 4. Load regulation measured from 60% to full load and from 60% to 20% load (60% ±40% load). AC-DC Output Voltage Output Current Ripple & Noise(2) Initial Set Accuracy(1) Line Regulation(3) Load Regulation(4) Model Number

4.2 V 1000 mA 1% ±3% ±1% ±4% AEP06US042

5.0 V 1200 mA 1% ±3% ±1% ±4% AEP06US05

6.0 V 1000 mA 1% ±3% ±1% ±4% AEP06US06

6.5 V 650 mA 1% ±3% ±1% ±3% AEP06US065

7.0 V 650 mA 1% ±3% ±1% ±3% AEP06US07

7.5 V 650 mA 1% ±3% ±1% ±3% AEP06US075

8.0 V 650 mA 1% ±3% ±1% ±3% AEP06US08

9.0 V 650 mA 1% ±3% ±1% ±2% AEP06US09

10.0 V 600 mA 1% ±3% ±1% ±2% AEP06US10

12.0 V 500 mA 1% ±3% ±1% ±2% AEP06US12

Mechanical Details 6 & 15 Watt Models 2.83 (72.0) 1.38 (35.0) 0.50 (12.7) 0.67 (17.0) 70.87 ±1.97 (1800.0 ±50.0) 2.05 (52.0)2.71 (68.9) 2.83 (72.0) 1.38 (35.0) 2.83 (72.0) 1.38 (35.0) 0.54 (13.7) 0.71 (18.0) 0.75 (19.0) 70.87 ±1.97 (1800.0 ±50.0) 2.05 (52.0)3.53 (89.7) 0.67 (17.0) 70.87 ±1.97 (1800.0 ±50.0) 2.05 (52.0) 3.31 (84.0) 2.83 (72.0) 1.38 (35.0) 0.71 (18.0) 70.87 ±1.97 (1800.0 ±50.0) 2.05 (52.0) 3.40 (86.3) 0.14 (3.5) 0.37 (9.5) All dimensions are in inches (mm) Weight:AEP06: 0.3 lb (135 g) AEP15: 0.35 lb (160 g) To order US add suffix’ -US’ to model number To order European add suffix’ -EU’ to model number To order Australian add suffix’ -AU’ to model number To order UK add suffix’ -UK’ to model number

AEP15-25Models and Ratings Notes 1. Initial set accuracy is at 60% full load. 2. Add a 0.1µF E.L capacitor to output for ripple & noise measurement at 20 MHz BW. 3. Line regulation measured from 100 VAC to 240 VAC, full load. 4. Load regulation measured from 60% to full load and from 60% to 20% load (60% ±40% load). Output Voltage Output Current Ripple & Noise(2) Initial Set Accuracy(1) Line Regulation(3) Load Regulation(4) Model Number 5.0 V 2.00 A 1% ±2% ±1% ±4% AEP15US05 6.0 V 1.50 A 1% ±2% ±1% ±4% AEP15US06 7.5 V 1.60 A 1% ±2% ±1% ±4% AEP15US075 9.0 V 1.40 A 1% ±2% ±1% ±4% AEP15US09 12.0 V 1.00 A 1% ±2% ±1% ±4% AEP15US12 13.6 V 1.00 A 1% ±2% ±1% ±4% AEP15US136 15.0 V 1.00 A 1% ±2% ±1% ±4% AEP15US15 18.0 V 0.83 A 1% ±2% ±1% ±4% AEP15US18 24.0 V 0.63 A 1% ±2% ±1% ±4% AEP15US24 3.3 V 4.00 A 50 mV pk-pk ±2% ±1% ±6% AEP25US033 5.0 V 4.00 A 1% ±2% ±1% ±6% AEP25US05 12.0 V 2.10 A 1% ±2% ±1% ±5% AEP25US12 15.0 V 1.67 A 1% ±2% ±1% ±3% AEP25US15 18.0 V 1.40 A 1% ±2% ±1% ±2% AEP25US18 24.0 V 1.05 A 1% ±2% ±1% ±2% AEP25US24 Mechanical Details 25 Watt Models 3.19 (81.0) 2.20 (56.0) 3.19 (81.0) 3.19 (81.0) 70.87 ±1.97 (1800.0 ±50.0) 1.89 (48.0) 3.19 (81.0) 2.20 (56.0) 70.87 ±1.97 (1800.0 ±50.0) 1.89 (48.0) 3.19 (81.0) 2.20 (56.0) 3.19 (81.0) 3.19 (81.0) 3.19 (81.0) 2.20 (56.0) 70.87 ±1.97 (1800.0 ±50.0) 1.89 (48.0) 70.87 ±1.97 (1800.0 ±50.0) 1.89 (48.0) All dimensions are in inches (mm) For 15 Watt modelmechanical details see 6 Watt model Weight:0.485 lb (220 g) To order US add suffix’ -US’ to model number To order European add suffix’ -EU’ to model number To order Australian add suffix’ -AU’ to model number To order UK add suffix’ -UK’ to model number