  • Output Voltages from 2.5 V to 48 V
  • Non-standard Outputs Available
  • Universal Input
  • Single & Multiple Output Versions
  • 0 °C to +70 °C Operating Temperature
  • Efficiency up to 80%
  • Non-standard Connectors Available AEH Series Input Input Voltage • 90-264 VAC Input Frequency • 47-63 Hz Input Current • 1.5/0.7 A for AEH45, at 115/230 VAC 1.9/1.5 A for AEH80, at 115/230 VAC 3.2/1.7 A for AEH130, at 115/230 VAC Inrush Current • AEH45 & 80: 30 A max at 230 VAC AEH130: 60 A max at 230 VAC cold start Power Factor • EN61000-3-2 class A Earth Leakage Current • <0.5 mA max at 115 VAC/60 Hz <0.75 mA max at 230 VAC/50 Hz Output Output Voltage • See tables. Factory set non-standard voltages available - contact sales Initial Set Accuracy •5 % Start Up Delay • 2 s max Hold Up Time • 16 ms min (>50 ms AEH130) Line Regulation • See note 2 Load Regulation • See note 2 Transient Response • 4% max deviation, recovery to within 1% in 4 ms for a 50% load change Ripple & Noise • 2% pk-pk for outputs ≤3.3 V 1% pk-pk for all other outputs

20 MHz BW

Overvoltage Protection • 112-132% Vnom, auto reset Overload Protection • Output 1 only 110-150% of nominal Temperature • ±0.04%/°C max Coefficient xppower.com General Efficiency • Up to 80% Isolation • 3000 VAC Input to Output

1500 VAC Input to Ground

500 VAC Output to Ground

Switching Frequency • 67-83 kHz for AEH45 58 kHz typical for AEH80 53-76 kHz for AEH130 MTBF • 100 kHrs per MIL-HDBK-217F Environmental Operating Temperature • 0 °C to +70 °C, derate linearly from 100% load at +40 °C to 50% load at +70 °C Operating Humidity • 5-95% RH, non-condensing Storage Temperature • -40 °C to +85 °C Vibration • 2 g on 3 axes EMC & Safety Emissions • EN55022 level B, conducted and radiated Harmonic Currents • EN61000-3-2, Class A Voltage Flicker • EN61000-3-2 ESD Immunity • EN61000-4-2, level 2 Perf Criteria A Radiated Immunity • EN61000-4-3, level 3 Perf Criteria A EFT/Burst • EN61000-4-4, level 2 Perf Criteria A Surge • EN61000-4-5, level 3 Perf Criteria A Conducted Immunity • EN61000-4-6, level 2 Perf Criteria A Dips & Interruptions • EN61000-4-11 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B Safety Approvals • EN60950-1, UL60950-1, CSA C22.2 No. 950 per cUL, CE Mark

Output 1(1,2) Output 2(1,2) Output 3(1,2) Model NumberVoltage Nom. Current Voltage Nom. Current Voltage Nom. Current Min Max Min Max Min Max 20 W 2.5 V 0.0 A 8.0 A AEH45US02 26 W 3.3 V 0.0 A 8.0 A AEH45US03 40 W 5.0 V 0.0 A 8.0 A AEH45US05 42 W 7.0 V 0.0 A 6.0 A AEH45US07 45 W 10.0 V 0.0 A 4.5 A AEH45US10 44 W 12.0 V 0.0 A 3.7 A AEH45US12 44 W 15.0 V 0.0 A 2.9 A AEH45US15 44 W 18.0 V 0.0 A 2.4 A AEH45US18 48 W 24.0 V 0.0 A 2.0 A AEH45US24 50 W 30.0 V 0.0 A 1.7 A AEH45US30 50 W 36.0 V 0.0 A 1.4 A AEH45US36 50 W 48.0 V 0.0 A 1.0 A AEH45US48 1. Factory-set non-standard outputs available in single output versions. 2. Total regulation including initial set accuracy, lin e and load regulation is typically 3% for output 1 and 5% for auxiliaries. 5.75 (146.0) ±1.0 2.99 (76.0) AC Input IEC 320-C14 Inlet 1.69 (43.0) DC Output

5 Pin Plug

  1. Dimensions shown in inches (mm). 2. Tolerance 0.02 (0.5) max. 3. Output cable length is 72” (1830mm) approx. 4. Optional output connectors available. Contact sales office. 5. Weight 0.9-1.1 lb (400-500 g) approx. 6. For UK mains lead order part: UK-MAINS-IEC. For European mains lead order part: EU-MAINS-IEC. 7. For mating DIN connector, use standard 5 pin 180º socket. DC OUTPUT PIN CONNECTIONS Pin SINGLE DUAL TRIPLE Shell GND GND GND

1 Common Common Common

2 Common Common Common

3 Output Output 1 Output 1

4 Common Common Output 3

5 Output Output 2 Output 2

Output 1(1,2) Output 2(1,2) Output 3(1,2) Model NumberVoltage Nom. Current Voltage Nom. Current Voltage Nom. Current Min Max Min Max Min Max 50 W 3.3 V 0.0 A 15.1 A AEH80US03 65 W 5.0 V 0.0 A 13.0 A AEH80US05 70 W 7.0 V 0.0 A 9.9 A AEH80US07 75 W 10.0 V 0.0 A 7.5 A AEH80US10 80 W 12.0 V 0.0 A 6.6 A AEH80US12 80 W 15.0 V 0.0 A 5.3 A AEH80US15 80 W 18.0 V 0.0 A 4.4 A AEH80US18 80 W 24.0 V 0.0 A 3.3 A AEH80US24 80 W 30.0 V 0.0 A 2.6 A AEH80US30 80 W 36.0 V 0.0 A 2.2 A AEH80US36 80 W 48.0 V 0.0 A 1.6 A AEH80US48 6.61 (167.9) ±1.0 3.09 (78.5) AC Input IEC 320-C14 Inlet 1.75 (44.5) DC Output

8 Pin Plug

  1. Dimensions shown in inches (mm). 2. Tolerance 0.02 (0.5) max. 3. Output cable length is 48” (1220mm) approx. 4. Optional output connectors available. Contact sales office. 5. Weight 0.9-1.1 lb (400-500 g) approx. 6. For UK mains lead order part: UK-MAINS-IEC, For European mains lead order part: EU-MAINS-IEC. 7. Optional ON/OFF switch. Add suffix ‘-S’. PIN CONNECTIONS Pin SINGLES DUAL TRIPLE 03, 05 V 07-48 V Shell GND GND GND GND

1 Common Common Common Common

2 Common Common Output 2 Output 3

3 Output Output Output 1 Output 1

4 Common Common Output 2 Output 2

5 Output Output Output 1 Output 2

6 Common Common Common

7 Output Output 1 Output 1

8 Output Common Output 3

  1. Factory-set non-standard outputs available in single output versions. 2. Total regulation including initial set accuracy, line and load regulation is typically 3% for output 1 and 5% for auxiliarie s.

Output 1(1,2) Output 2(1,2) Model NumberVoltage Nom. Current Total Regulation Voltage Nom. Current Total RegulationMin Max Min Max 90 W 3.3 V 0.0 A 27.2 A 7% AEH130PS3V3 115 W 5.0 V 0.0 A 23.0 A 7% AEH130PS05 130 W 7.0 V 0.0 A 18.5 A 7% AEH130PS07 130 W 9.0 V 0.0 A 14.4 A 5% AEH130PS09 130 W 12.0 V 0.0 A 10.8 A 5% AEH130PS12 130 W 15.0 V 0.0 A 8.6 A 5% AEH130PS15 130 W 18.0 V 0.0 A 7.2 A 5% AEH130PS18 130 W 24.0 V 0.0 A 5.4 A 5% AEH130PS24 130 W 28.0 V 0.0 A 4.6 A 5% AEH130PS28 130 W 36.0 V 0.0 A 3.6 A 5% AEH130PS36 130 W 48.0 V 0.0 A 2.7 A 3% AEH130PS48 130 W 54.0 V 0.0 A 2.4 A 3% AEH130PS54 1. Factory-set non-standard outputs available in single output versions. 2. Total regulation includes initial set accuracy, line and load regulation. 0.85 (21.5) 1.14 (29.0) AC Input IEC 320-C14 Inlet 8 76 PIN CONNECTIONS Pin SINGLE DUAL Shell GND GND

1 Common Common

2 Common Output 2

3 Output Output 1

4 Common Output 2

5 Output Output 1

6 Common Common

7 Output Output 1

8 Output Common

  1. Dimensions shown in inches (mm). 2. Tolerance 0.02 (0.5) max. 3. Output cable length is 48” (1220mm) approx. 4. Optional output connectors available. Contact sales office. 5. Weight 1.9 lb (860 g) approx. 6. For UK mains lead order part: UK-MAINS-IEC, For European mains lead order part: EU-MAINS-IEC. Notes