- Low Profile
- Single Outputs from 5 V to 48 V
- Universal Input
- Optional Floating Output
- High Power Density
- 36, 45, 70 & 100 W Versions
- Class II Insulation on 36 W Version AED Series Input Input Voltage • 90-264 VAC Input Frequency • 47-63 Hz Input Current • AED36: 1.00 A max AED45: 1.20 A max AED70: 1.85 A max AED100: 2.00 A max Inrush Current • AED36: 50 A max at 230 VAC AED45: 100 A max at 230 VAC AED70: 100 A max at 230 VAC AED100: 100 A max at 230 VAC Earth Leakage Current • AED36: Class II AED45: 1.5 mA max AED70: 1.5 mA max AED100: 1.5 mA max Power Factor • Compliant with EN61000-3-2 Output Output Voltage • See tables Initial Set Accuracy •± 2 % Minimum Load • No minimum load requirement Hold Up Time • AED36: 8 ms min at 115 VAC AED45: 8 ms min at 115 VAC AED70: 8 ms min at 115 VAC AED100: 20 ms typical at 115 VAC Line Regulation •± 1 % Load Regulation • See tables Ripple & Noise • 1% pk-pk max, 20 MHz BW (see note 2) Overvoltage Protection • Typical 125% max Overload Protection • 120-150% hiccup/trip & restart mode with auto recovery Short Circuit Protection • Continuous Temperature • ±0.04%/˚C Coefficient xppower.com General Efficiency • 85% typical at 230 VAC & 100% load Isolation • 3000 VAC Input to Output, 1500 VAC Input to Ground. Negative output is connected to ground. For optional 500 VAC output to ground isolation add suffix ‘-F’ to model number Switching Frequency • 60 kHz ±10 kHz MTBF • 100,000 Hrs to MIL-HDBK-217E Environmental Operating Temperature • 0 ˚C to +65 ˚C AED36, AED45 & AED70 derate linearly from 100% load at +40 ˚C to 50% load at +55 ˚C, AED100 derate linearly from 100% load at +40 ˚C to 0% at +65 ˚C Storage Temperature • -20 ˚C to +85 ˚C EMC & Safety Emissions • CISPR22 Level B (EN55022) FCC 20780 Level B ESD Immunity • EN61000-4-2, 8 kV air 4 kV contact Perf Criteria A Radiated Immunity • EN61000-4-3, 3 V/m Perf Criteria A EFT/Burst • EN61000-4-4, level 2 Perf Criteria A Safety Approvals • EN60950-1, UL60950-1, CAN/CSA C22.2 No. 60950 cUL
AED SeriesModels and Ratings Output Power Maximum Output Voltage Nominal Output Current Maximum Load Regulation(1) Model Number 20 W 5.0 V 4.00 A ±6% AED36US05 27 W 9.0 V 3.00 A ±5% AED36US09 30 W 12.0 V 2.50 A ±5% AED36US12† 32 W 13.5 V 2.40 A ±5% AED36US13 36 W 15.0 V 2.40 A ±3% AED36US15† 36 W 18.0 V 2.00 A ±2% AED36US18† 36 W 24.0 V 1.50 A ±2% AED36US24† 36 W 48.0 V 0.75 A ±2% AED36US48 30 W 5.0 V 6.00 A ±6% AED45US05 45 W 12.0 V 3.75 A ±5% AED45US12 45 W 15.0 V 3.00 A ±3% AED45US15† 45 W 18.5 V 2.50 A ±2% AED45US18† 45 W 19.0 V 2.37 A ±2% AED45US19 45 W 24.0 V 1.88 A ±2% AED45US24† 48 W 48.0 V 1.00 A ±2% AED45US48 66 W 12.0 V 5.50 A ±5% AED70US12^ 69 W 15.0 V 4.60 A ±3% AED70US15^ 70 W 18.0 V 3.90 A ±2% AED70US18^ 72 W 19.0 V 3.70 A ±2% AED70US19^ 72 W 24.0 V 3.00 A ±2% AED70US24^ 72 W 48.0 V 1.50 A ±2% AED70US48^ 100 W 12.0 V 8.33 A ±4% AED100US12†^ 100 W 15.0 V 6.67 A ±4% AED100US15†^ 100 W 18.0 V 5.56 A ±2% AED100US18†^ 100 W 19.0 V 5.26 A ±2% AED100US19†^ 100 W 24.0 V 4.17 A ±2% AED100US24†^ 100 W 48.0 V 2.08 A ±2% AED100US48†^ Mechanical Details Notes 1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% full load). 2. Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor. † Available from Farnell. See pages 204-206. ^ Available from Newark. See page 207-208. 4.33 (110) 0.79 (20) 1.97 (50) IEC320-C8 0.47 (12.00)
36 Watt Models
lb (g)A B C Weight: 0.37 lbs (170 g) approx. Power Cord Order Part: UK - UK-MAINS-8 European - EU-MAINS-8 US - US-MAINS-8 All dimensions shown in inches (mm). B A C IEC320-C14 0.47 (12.00) Notes Optional output connectors available. Output cable is 48” (1220mm) approx. Power Cord Order Part: UK - UK-MAINS-IEC European - EU-MAINS-IEC US - US-MAINS-IEC