AED XPPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
- Low Profile
- Single Outputs from 5 V to 48 V
- Universal Input
- Optional Floating Output
- High Power Density
- Class II Insulation on 36 W Version
- 3 Year Warranty AED Series Input Input Voltage • 90-264 VAC Input Frequency • 47-63 Hz Input Current • AED36: 1.00 A max AED45: 1.20 A max AED70: 2.00 A max Inrush Current • AED36: 50 A max at 230 VAC AED45: 100 A max at 230 VAC AED70: 100 A max at 240 VAC Earth Leakage Current• AED36: Class II AED45/70: 3.5 mA max Power Factor • Compliant with EN61000-3-2 Output Output Voltage • See tables Initial Set Accuracy • ±2% Minimum Load • No minimum load requirement Hold Up Time • AED36: 8 ms min at 115 VAC AED45: 8 ms min at 115 VAC AED70: 20 ms min at 115 VAC Line Regulation • ±1% Load Regulation • See tables Ripple & Noise • 1% pk-pk max, 20 MHz BW (see note 2) Overvoltage Protection• Typical 125% max Overload Protection • 120-150% hiccup/trip & restart mode with auto recovery Short Circuit Protection• Continuous Temperature • ±0.05%/˚C Coefficient xppower.com General Efficiency • 85% typical at 230 VAC & 100% load Isolation • 3000 VAC Input to Output, 1500 VAC Input to Ground. Negative output is connected to ground. For optional 500 VAC output to ground isolation add suffix ‘-F’ to model number Switching Frequency • 60 kHz ±10 kHz Power Density • AED36: 5.34 W/in3 AED45: 3.20 W/in3 AED70: 4.98 W/in3 MTBF • 200 kHrs to MIL-HDBK-217F at 25 °C, GB Environmental Operating Temperature• 0 ˚C to +60 ˚C derate linearly from 100% load at +40 ˚C to 50% load at +60 ˚C Operating Humidity • 93% RH, non-condensing Operating Altitude • 2000 m Storage Temperature • -20 ˚C to +85 ˚C EMC & Safety Emissions • EN55022 Class B conducted & radiated Harmonic Currents • EN61000-3-2, Class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, 8 kV air, 4 kV contact Perf Criteria A Radiated Immunity • EN61000-4-3, 3 V/m Perf Criteria A EFT/Burst • EN61000-4-4, level 2 Perf Criteria A Safety Approvals • EN60950-1, UL60950-1
4.33 (110) 0.79 (20) 1.97 (50) IEC320-C8 0.47 (12.00) AC-DC AED36Models and Ratings Output Power Maximum Output Voltage Nominal Output Current Maximum Load Regulation(1) Model Number 20 W 5.0 V 4.00 A ±6% AED36US05 27 W 9.0 V 3.00 A ±5% AED36US09 30 W 12.0 V 2.50 A ±5% AED36US12 32 W 13.5 V 2.40 A ±5% AED36US13 36 W 15.0 V 2.40 A ±3% AED36US15 36 W 18.0 V 2.00 A ±2% AED36US18 36 W 24.0 V 1.50 A ±2% AED36US24 36 W 48.0 V 0.75 A ±2% AED36US48 Mechanical Details Notes 1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% full load). 2. Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor. Weight:0.42 lbs (190 g) approx. Power Cord Order Part: UK -UK-MAINS-8 European -EU-MAINS-8 US -US-MAINS-8 Notes All dimensions shown in inches (mm) Optional output connectors available. Output cable is 48” (1220mm) approx.
2.29 (58) 1.18 (30) 5.20 (132) IEC320-C14 0.47 (12.00) AED45Models and Ratings Output Power Maximum Output Voltage Nominal Output Current Maximum Load Regulation(1) Model Number 30 W 5.0 V 6.00 A ±6% AED45US05 45 W 12.0 V 3.75 A ±5% AED45US12 45 W 15.0 V 3.00 A ±3% AED45US15 45 W 18.5 V 2.50 A ±2% AED45US18 45 W 19.0 V 2.37 A ±2% AED45US19 45 W 24.0 V 1.88 A ±2% AED45US24 48 W 48.0 V 1.00 A ±2% AED45US48 Mechanical Details Notes 1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% full load). 2. Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor. Notes All dimensions shown in inches (mm) Optional output connectors available. Output cable is 48” (1220mm) approx. Weight:0.73 lbs (330 g) approx. Power Cord Order Part: UK -UK-MAINS-IEC European -EU-MAINS-IEC US -US-MAINS-IEC
Regulation(1) Model Number 70 W 12.0 V 5.50 A ±5% AED70US12 70 W 15.0 V 4.60 A ±3% AED70US15 70 W 18.0 V 3.90 A ±2% AED70US18 70 W 19.0 V 3.70 A ±2% AED70US19 70 W 24.0 V 3.00 A ±2% AED70US24 70 W 48.0 V 1.50 A ±2% AED70US48 Mechanical Details Notes 1. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% full load). 2. Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor. 5.20 (132.0) 2.28 (58.0) 1.18 (30.0) IEC320-C14 0.47 (12.0) Notes All dimensions shown in inches (mm). Output connector is 5.5mm dia. outer barrel, inner dia. is 2.5mm with a center + and outer shell - polarity. 2. Optional output connectors available. 3. Output cable is 48” (1220mm) approx. Weight:0.76 lbs (345 g) approx. Power Cord Order Part: UK -UK-MAINS-IEC European -EU-MAINS-IEC US -US-MAINS-IEC