AE417 RFHIC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
(Preliminary) ▪ Tel : 82-31-250-5011 ▪ All specifications may change without notice. ▪ rfsales@rfhic.com ▪ Version 0.2 Product Features Application
- Small size
- Higher linearity
- SOT89 SMD Type package
- Higher productivity
- Lower manufacturing cost
- -63dBc CSO 135 Channels @ +30dBmV/ch
- -74dBc CTB 135 Channels @ +30dBmV/ch
- -73dBc XMD 135 Channels @ +30dBmV/ch
- Low Noise Amplifier for CATV , Satellite
- Cable Modem
- FTTH (G-PON, GE-PON)
- Optical node
Description
AE417 is designed as low cost drive amplifiers for many applications including FTTH, CATV System. This MMIC is based on Gallium Arsenide Enhancement Mode pHEMT which shows low current draw and very low noise. The data in this spec sheet is valid only for 75 ohm application. Specifications PARAMETER UNIT MIN TYP MAX Condition Frequency MHz 50 ~ 1000 Gain dB 11 Input Return Loss dB -19 Output Return Loss dB -18 Output IP3 dBm 38 41 At 500MHz/10dBm 2tone 1dB Compression Point dBm 22 24.8 At 500MHz Noise Figure dB 4 5 CSO dBc -63 -58 135 channel, +30dBmV/ch CTB 30 ~ 870MHz dBc -74 -69 135 channel, +30dBmV/ch XMOD dBc -73 -68 135 channel, +30dBmV/ch DC Current mA 115 Vdd = 8.0V Absolute Minimum and Maximum Ratings PARAMETER UNIT MIN TYP MAX Device V oltage VDC +8 +9 Operating Temperature ℃ -40 +85 Storage Temperature ℃ -40 +150 NOTE 1. Test conditions unless otherwise noted. Test Freq = 500MHz, T=25℃, Vdd=8V , 75Ω system 2. OIP3 measured with 2 tones at an output power of +10dBm/tone separated by 1MHz, Test Freq = 500MHz Package : SOT-89
(Preliminary) ▪ Tel : 82-31-250-5011 ▪ All specifications may change without notice. ▪ rfsales@rfhic.com ▪ Version 0.2 ◎ Application Circuit: 50MHz ~ 1000MHz, 75ohm System +8V Output10 nFInput AE417 1 pF 10 nF 8.2nH 100nF 820nH (Wirewround Type) 10nF 6.8nH 4.7uF (Tantal) 1Kohm 1 pF ◎ Typical RF Performance: VDD=8V , IDS=115mA, T=25℃, 75ohm System -10 -20 -10 -30 Freq(GHz) Gain(dB) Return Loss(dB) S-Parameter ◎ Multi-Tone Test 135CH_FLAT@Output Power +30dBmV/Ch Level: +30dBmV Tilt: 135CH_FLAT FRQ XMD(NCTA) CTB_RAW CTB_COR N-FLR CSU_RAW CSU_COR CSU_FRQ CSL_RAW CSL_COR CSL_FRQ S21 S11 S22 Noise Figure vs Frequency 10 200 400 600 800 1000 Freq(MHz) NF(dB)
(Preliminary) ▪ Tel : 82-31-250-5011 ▪ All specifications may change without notice. ▪ rfsales@rfhic.com ▪ Version 0.2 For a safe use in all situations, it is recommended to have proper ESD control techniques while the device is being handled. Here are some recommended precautions; - Person at a workbench should be earthed via a wrist strap and a resistor. - All mains-powered equipment should be connected to the mains via an earth-leakage switch. - Equipment cases should be grounded. - Relative humidity should be maintained between 40% and 50%. - An ionizer is recommended. - Keep static materials, such as plastic envelopes and plastic trays etc. away from the workbench PCB Pad Layout Recommended Mounting Configuration ESD Protection Dimensions Pin No Function
1 Input
2 Ground
3 Output/Bias
4 Ground
Mounting Configuration Notes 1.Ground / thermal via holes are critical for the proper performance of this device. 2. Add as much copper as possible to inner and outer layers near the part to ensure optimal thermal performance. 3. Mounting screws can be added near the part to fasten the board to a heatsink. Ensure that the ground / thermal via hole region contacts the heatsink. 4. Do not put solder mask on the backside of the PCB in the region where the board contacts the heatsink. 5. RF trace width depends upon the PCB material and construction. 6. Use 1 oz. Copper minimum. 7. All dimensions are in millimeters. RFHIC Corporation (RFHIC) reserves the right to make changes to any products herein or to discontinue any product at any time w ithout notice. RFHIC do not assume any liability for the suitability of its products for any particular purpose, and disclaims any and all liability, inclu ding without limitation consequential or incidental damages. The product specifications herein expressed have been carefully checked and are assumed to be reliable. However, RFHIC disclaims liability for inaccuracies and strongly recommends buyers to verify that the information they are using is current before placing purchase or ders. RFHIC products are not intended for use in life support equipment or application where ma lfunction of the product can be expected to result in persona l injury or death. Buyer uses or sells such products for any such unintended or unauthorized applicatio n, buyer shall indemnify, protect and hold RFHIC and its direct ors, officers, stockholders, employees, representatives and distributors harmless against any and all claims arising out of such use. RFHIC’s liability under or arising out of damages, claims of whatsoever kind and nature which RFHIC products could cause shall be limited in amount to the net purchase price of the products sold to buyer by RFHIC.