Features

Repe◆ titive Peak Off-State Voltage: 1000V/1200V/1600V R.M.S On◆ -State Current ( IT(RMS)= 60A ) High Commutation dv/dt◆ ◆ These Devices are Pb-Free and are RoHS Compliant Absolute Maximum Ratings Scan the QR code to view the latest product information ADV 2.T2 1.T1 3.Gate 1 2 3 TO-3PL

2 / 4 www.advsemi.com Feb,2013 -Rev.3.02 ADV Electrical Characteristics( Tj = 25°C unless otherwise specified ) Symbol Items Conditions ADS60C100L/120L/160L Unit IDRM IRRM Peak Forward Reverse Blocking Current VDRM = VRRM, Tj = 25°C Max. 50 uA VDRM = VRRM, Tj = 125°C 8 mA VTM Peak On-State Voltage I TM = 80A, tp = 380 μs Max. 1.75 V VGD Q1-Q2-Q3 Non−Trigger Gate Voltage VD = VDRM R L = 3.3 kΩ Tj = 125°C Min. 0.2 V VGT Q1-Q2-Q3 Gate Trigger Voltage VD = 12V ,RL = 33Ω Max. 1.3 V IGT Q1-Q2-Q3 Gate Trigger Current Max. 50 mA IH Q1-Q2-Q3 Holding Current I T = 0.5A Max. 75 mA IL Q1-Q3 Latching Current I G = 1.2 IGT Max. mA Q2 120 dV/dt Critical Rate of Rise of Off-State Voltage VD = 2/3VDRM gate open Tj = 125°C Min. 1000 V/ μs (dV/dt)c Critical Rate of Change of Commutating Voltage (dI/dt)c=-23A/ms Tj = 125°C Min. 20 V/ μs Rth(j-c) Junction to case (AC) Max. 0.38 ° C/W Rth(j-a) Junction to ambient Max. 40 ° C/W V A VD RGV A VD RGV A VD RG V A VD RG RL T2+ T2- Q1(T2+G+) Q3(T2-G-) Q2(T2+G-) RL RL G+G- FIG.1:Triac quadrant are defined and the gate trigger test circuit

3 / 4 www.advsemi.com Feb,2013 -Rev.3.02 ADV Part number Package Marking Packing Quantity ADS60C100L TO-3PL ADS60C100L Tube 25pcs ADS60C120L TO-3PL ADS60C120L Tube 25pcs ADS60C160L TO-3PL ADS60C160L Tube 25pcs H F E B D CG A P J J L φ PACKAGE MECHANICAL DATA Making Diagram

Ordering information

A 2.40TYP 0.095TYP B 1.92TYP 0.075TYP C 24.56 25.46 0.967 1.002 E 3.84TYP 0.151 TYP F 5.76TYP 0.227 TYP G 19.70 20.30 0.775 0.799 H 20.05 0.789 J 54.35 54.65 2.139 2.151 P1 2.40TYP 0.094 TYP P2 2.88TYP 0.113 TYP P 0.71 1.26 0.028 0.049 L1 2.67TYP 0.105 L 5.20 0.204 L3 0.58TYP 0.022 TYP Φ 3.17TYP 0.124 TYP ADV ADS60C120L XXXX XXXH XX ADV:Logo ADS60C120L:Part number X:Internal control code H:Halogen Free ADVANCED Internal control code Current:60=60A Quadrant:C=3Q Voltage:100=1000V 120=1200V 160=1600V Package explain:L=TO-3PL

4 / 4 www.advsemi.com Feb,2013 -Rev.3.02 ADV Notice 1. All information included in this document such as product data, diagrams, charts, programs, algorithms, and application circuit examples, is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any ADV products listed in this document, please confirm the latest product information with a ADV sales office. Also, please pay regular and careful attention to additional and different information to be disclosed by ADV such as that disclosed through our website. (http://www.advsemi.com ) 2. ADV has used reasonable care in compiling the information included in this document, but ADV assumes no liability whatsoever for any damages incurred as a result of errors or omissions in the information included in this document. 3. You should use the products described herein within the range specified by ADV, especially with respectvto the maximum rating, operating supply voltage range, movement power voltage range, heat radiation characteristics, installation and other product characteristics. ADV shall have no liability for malfunctions or damages arising out of the use of ADV products beyond such specified ranges. 4. When using or otherwise relying on the information in this document, you should evaluate the information in light of the total system before deciding about the applicability of such information to the intended application.ADV makes no representations, warranties or guaranties regarding the suitability of its products for any particular application and specifically disclaims any liability arising out of the application and use of the information in this document or ADV products. 5. Although ADV endeavors to improve the quality and reliability of its products, IC products have specific characteristics such as the occurrence of failure at a certain rate and malfunctions under certain use conditions. Please be sure to implement safety measures to guard against the possibility of physical injury, and injury or damage caused by fire in the event of the failure of a ADV product, such as safety design for hardware and software including but not limited to redundancy, fire control and malfunction prevention, appropriate treatment for aging degradation or any other applicable measures. Among others, since the evaluation of microcomputer software alone is very difficult, please evaluate the safety of the final products or system manufactured by you. 6. This document is provided for reference purposes only so that ADV customers may select the appropriate ADV products for their use. ADV neither makes warranties or representations with respect to the accuracy or completeness of the information contained in this document nor grants any license to any intellectual property rights or any other rights of ADV or any third party with respect to the information in this document. 7. ADV shall have no liability for damages or infringement of any intellectual property or other rights arising out of the use of any information in this document, including, but not limited to, product data, diagrams, charts,programs, algorithms, and application circuit examples. 8. This document may not be reproduced or duplicated, in any form, in whole or in part, without prior written approval from ADV.