ADE20 REICU | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 1

Technical content

Features

Efficiency up to 80% 2500VAC Isolation Model Selection Guide Order Code Efficiency(%) (Typ)Vo(V) Io(mA) Output AD5-S03 AD5-S05 AC(V) DC(V) Input 1000 1000 3.3 Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB mounting design Plastic case Universal Input :85 ~ 264VAC,50/60Hz AD5 Series AC/DC CONVERTER AD5-S09 AD5-S12 AD5-S15 AD5-S24 Design & Feature Considerations Reduce output ripple, it is recommended to use capacitors at the output. 1. Output Ripple Reduction It is recommended to use 47~100uF capacitors at the output. Tthe products provide protection against overload, the unit is equipped with internal current limiting circuitry . 2. Overload Protection AD5-D05 +12 +15 AD5-D12 AD5-D15 85-264 120-370 +500 556 417 333 208 +208 +167 Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1% %

60 KHzSwitching frequency Full load,nominal input

Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms AD5-D05-24 AD5-D05-12 5/5 800/200AD5-D05-05 5/12 800/100 -25 +85 -40 +105

2500 VAC

MΩ500 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Case material Platic Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area Design & Feature Considerations Reduce output ripple, it is recommended to use capacitors at the output. 1. Output Ripple Reduction It is recommended to use 47~100uF capacitors at the output. Tthe products provide protection against overload, the unit is equipped with internal current limiting circuitry . 2. Overload Protection AC(L) AC(N) +Vo DC/DC Converter Cout Load Lateral View Mechanical Dimension & Pin Connections Bottom View 45.0 (1.77) 35.00 (1.38) 55.0(2.17) 10.0 (0.390) 47.0(1.85) 20.0 (0.79) 20.5(0.81) 6.10(0.24) 1.00 (0.04) DualNote: Unit:mm(inch) NC N L +Vo 1 2 3Pin 4 Single 5 6 7 8 NP NP NP -Vo Dual Island NC N L NC N L +Vo NP COM -VoNP +Vo2 -Vo2 NP +Vo1 -Vo1 Recommend capacitive(uF) Page 1 of 2 REV:13.1 Page 2 of 2 REV:13.1 AD10 Series AC/DC CONVERTER 10W Efficiency up to 81% 2500VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB Mounting mesign Plastic case Model Selection Guide Order Code Efficiency(%) (Typ)Vo(V) Io(mA) Output AD10-S03 AD10-S05 AC(V) DC(V) Input 2000 2000 3.3 Universal Input :85 ~ 264VAC,50/60Hz AD10 Series AC/DC CONVERTER AD10-S09 AD10-S12 AD10-S15 AD10-S24 AD10-D05 +12 +15 AD10-D12 AD10-D15 85-264 120-370 +1000 1111 833 667 417 +417 +333 Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1% % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms AD10-D05-05 AD10-D05-24 5/12 1600/200AD10-D05-12 5/24 1600/100 -25 +85 -40 +105 MΩ500 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Case material Platic Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area Recommend capacitive(uF) Lateral View Mechanical Dimension & Pin Connections Bottom View DualNote: Unit:mm(inch) NC N L +Vo 1 2 3Pin 4 Single 5 6 7 8 NP NP NP -Vo Dual Island NC N L NC N L +Vo NP COM -VoNP +Vo2 -Vo2 NP +Vo1 -Vo1 45.0 (1.77) 35.00 (1.38) 62.0(2.40) 10.0 (0.39) 54.0(2.13) 20.0 (0.79) 22.5(0.89) 6.10(0.24) 1.00 (0.04) Page 1 of 3 REV:15.1 Page 2 of 3 REV:15.1 AD15 Series AC/DC CONVERTER 15W Efficiency up to 81% 3000VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB Mounting mesign Plastic case Model Selection Guide Order Code Efficiency(%) (Typ)Vo(V) Io(mA) Output AD15-S03 AD15-S05 AC(V) DC(V) Input 3000 3000 3.3 Universal Input :85 ~ 264VAC,50/60Hz AD15 Series AC/DC CONVERTER AD15-S09 AD15-S12 AD15-S15 AD15-S24 AD15-D05 +12 +15 AD15-D12 AD15-D15 85-264 120-370 +1500 1667 1250 1000 625 +625 +500 Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1% % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms AD15-D05-05 AD15-D05-24 5/12 2000/400AD15-D05-12 5/24 2000/200 -25 +85 -40 +105

3000 VAC

MΩ500 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Recommend capacitive(uF) Lateral View Mechanical Dimension & Pin Connections Bottom View DualNote: Unit:mm(inch) NC N L +Vo 1 2 3Pin 4 Single 5 6 7 8 NP NP NP -Vo Dual Island NC N L NC N L +Vo NP COM -VoNP +Vo2 -Vo2 NP +Vo1 -Vo1 45.0 (1.77) 35.00 (1.38) 62.0(2.40) 10.0 (0.39) 54.0(2.13) 20.0 (0.79) 22.5(0.89) 6.10(0.24) 1.00 (0.04) Page 1 of 2 REV:15.1 Page 2 of 2 REV:15.1 ADM15 Series AC/DC CONVERTER 15W Efficiency up to 83% 3000VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB Mounting mesign Plastic case Model Selection Guide Order Code Efficiency(%) (Typ)Vo(V) Io(mA) Output ADM15-S03 ADM15-S05 AC(V) DC(V) Input 3000 3000 3.3 Universal Input :85 ~ 264VAC,50/60Hz ADM15 Series AC/DC CONVERTER ADM15-S09 ADM15-S12 ADM15-S15 ADM15-S24 ADM15-D05 +12 +15 ADM15-D12 ADM15-D15 85-264 120-370 +1500 1667 1250 1000 625 +625 +500 Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1% % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms ADM15-D05-05 ADM15-D05-24 5/12 1800/500ADM15-D05-12 5/24 1600/300 -25 +85 -40 +105 MΩ500 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Case material Platic Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area Recommend capacitive(uF) Lateral View Mechanical Dimension & Pin Connections Bottom View DualNote: Unit:mm(inch) NC N L +Vo 1 2 3Pin 4 Single 5 6 7 8 NP NP NP -Vo Dual Island NC N L NC N L +Vo NP COM -VoNP +Vo2 -Vo2 NP +Vo1 -Vo1 45.0 (1.77) 35.00 (1.38) 55.0(2.17) 10.0 (0.390) 47.0(1.85) 20.0 (0.79) 20.5(0.81) 6.10(0.24) 1.00 (0.04) Page 1 of 3 REV:15.1 Page 2 of 3 REV:15.1 AD20 Series AC/DC CONVERTER 20W Efficiency up to 84% 3000VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB Mounting mesign Plastic case Model Selection Guide Order Code Efficiency(%) (Typ)Vo(V) Io(mA) Output AD20-S03 AD20-S05 AC(V) DC(V) Input 4000 4000 3.3 Universal Input :85 ~ 264VAC,50/60Hz AD20 Series AC/DC CONVERTER AD20-S09 AD20-S12 AD20-S15 AD20-S24 AD20-D05 +12 +15 AD20-D12 AD20-D15 85-264 120-370 +2000 2222 1667 1333 833 +833 +667 Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1% % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms AD20-D05-05 AD20-D05-24 5/12 3000/400AD20-D05-12 5/24 3000/200 -25 +85 -40 +105 MΩ500 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Recommend capacitive(uF) Page 1 of 2 REV:13.1 Page 2 of 2 REV:13.1 ADM20 Series AC/DC CONVERTER 20W Efficiency up to 81% 2500VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB Mounting mesign Plastc case Model Selection Guide Order Code Efficiency(%) (Typ)Vo(V) Io(mA) Output AC(V) DC(V) Input Universal Input :85 ~ 264VAC,50/60Hz ADM20 Series AC/DC CONVERTER ADM20-S12 ADM20-S15 ADM20-S24 +12 +15 ADM20-D12 ADM20-D15 85-264 120-370 1667 1333 833 +833 +667 Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1% % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms -25 +85 -40 +105 MΩ500 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Case material Platic Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area Recommend capacitive(uF) Lateral View Mechanical Dimension & Pin Connections Bottom View DualNote: Unit:mm(inch) NC N L +Vo 1 2 3Pin 4 Single 5 6 7 8 NP NP NP -Vo Dual Island NC N L NC N L +Vo NP COM -VoNP +Vo2 -Vo2 NP +Vo1 -Vo1 45.0 (1.77) 35.00 (1.37) 62.0(2.40) 10.0 (0.39) 54.0(2.13) 20.0 (0.79) 22.5(0.89) 6.10(0.24) 1.00 (0.04) Page 1 of 3 REV:15.1 Page 2 of 3 REV:15.1 AD25 Series AC/DC CONVERTER 25W Efficiency up to 84% 3000VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB Mounting mesign Plastic case Model Selection Guide Order Code Efficiency(%) (Typ)Vo(V) Io(mA) Output AD25-S03 AD25-S05 AC(V) DC(V) Input 5000 5000 3.3 Universal Input :85 ~ 264VAC,50/60Hz AD25 Series AC/DC CONVERTER AD25-S09 AD25-S12 AD25-S15 AD25-S24 AD25-D05 +12 +15 AD25-D12 AD25-D15 165-264 200-370+2500 2778 2083 1667 1042 +1042 +833 Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1% % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms AD25-D05-05 AD25-D05-24 5/12 4000/400AD25-D05-12 5/24 4000/200 -25 +85 -40 +105 MΩ500 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Recommend capacitive(uF) Page 1 of 2 REV:13.1 Page 2 of 2 REV:13.1 ADM25 Series AC/DC CONVERTER 25W Efficiency up to 85% 2500VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB Mounting mesign Metal case Model Selection Guide Order Code Efficiency(%) (Typ)Vo(V) Io(mA) Output ADM25-S03M ADM25-S05M AC(V) DC(V) Input 5000 5000 3.3 Universal Input :85 ~ 264VAC,50/60Hz ADM25 Series AC/DC CONVERTER ADM25-S09M ADM25-S12M ADM25-S15M ADM25-S24M ADM25-D05M +12 +15 ADM25-D12M AD25M-D15M 85-264 120-370 +2500 2778 2083 1667 1042 +1042 +833 Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1% % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms ADM25-D05-05M ADM25-D05-24M 5/12 4000/400ADM25-D05-12M 5/24 4000/200 -25 +85 -40 +105 MΩ500 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Case material Metal Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area Recommend capacitive(uF) Lateral View Mechanical Dimension & Pin Connections Bottom View DualNote: Unit:mm(inch) NC N L +Vo 1 2 3Pin 4 Single 5 6 7 8 NP NP NP -Vo Dual Island NC N L NC N L +Vo NP COM -VoNP +Vo2 -Vo2 NP +Vo1 -Vo1 45.0 (1.77) 35.00 (1.37) 62.0(2.40) 10.0 (0.39) 54.0(2.13) 20.0 (0.79) 22.5(0.89) 6.10(0.24) 1.00 (0.04) Page 1 of 3 REV:15.1 Page 2 of 3 REV:15.1 AD30 Series AC/DC CONVERTER 30W Efficiency up to 84% 3000VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB Mounting mesign Plastic case Model Selection Guide Order Code Efficiency(%) (Typ)Vo(V) Io(mA) Output AC(V) DC(V) Input Universal Input :85 ~ 264VAC,50/60Hz AD30 Series AC/DC CONVERTER Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1% % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms -25 +85 -40 +105 MΩ500 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Recommend capacitive(uF) AD30-S05 6000 AD30-S09 AD30-S12 AD30-S15 AD30-S24 AD30-D05 +12 +15 AD30-D12 AD30-D15 165-264 200-370 +3000 3333 2500 2000 1250 +1250 +1000 AD30-D05-05 AD30-D05-24 5/12 5000/400AD30-D05-12 5/24 5000/200 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note 330 330 220 220 220 100 1000 1000 470 470 470 330 1000 1000 470 470 470 330 1000 1000 470 470 470 330 2200 2200 680 680 680 470 680 680 470 2200 2200 680 680 680 470 22002200 2200 2200 680 680 680 470 22002200 2200 680 680 680 470 22002200 研发中 研发中 Single/Double output eR ICU eR ICU eR ICU eR ICU eR ICU eR ICU eR ICU eR ICU eR ICU eR ICU eR ICU eR ICU eR ICU eR ICU eR ICU eR ICU eR ICU eR ICU www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com Page 1 of 2 REV:15.2 www.reicu.com E-mail:service @reicu.com Page 2 of 2 REV:15.2 ADM5 Series AC/DC CONVERTER 5W Efficiency up to 79% 3000VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB mounting design Universal Input :85 ~ 264VAC,47~440Hz ADM5 Series AC/DC CONVERTER Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1% % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note -25 +70 -40 +105 MΩ500 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Case material plastic eR ICU eR ICU www.reicu.com E-mail:service @reicu.com Lateral View Mechanical Dimension & Pin Connections Bottom View Model Selection Guide Order Code Recommend capacitive(uF) Efficiency(%) (Typ)Vo(V) Io(mA) Output AC(V) DC(V) Input ADM5-S03 ADM5-S05 1000 1000 3.3 ADM5-S09 ADM5-S12 ADM5-S15 ADM5-S24 ADM5-D05 +12 +15 ADM5-D12 ADM5-D15 85-264 120-370 +500 556 417 333 208 +208 +167 ADM5-D05-24 ADM5-D05-12 5/5 800/200ADM5-D05-05 5/12 800/100 330 330 220 220 220 100 Plastic case 20.5(0.81) 6.10(0.24) 1.00 (0.04) 36.0 (1.42) 25.00 (0.98) 48.5(1.91) 8.0 (0.315) 40.5(1.59) 16.0 (0.63) DualNote: Unit:mm(inch) NC N L +Vo 1 2 3Pin 4 Single 5 6 7 8 NP NP NP -Vo Dual Island NC N L NC N L +Vo NP COM -VoNP +Vo2 -Vo2 NP +Vo1 -Vo1 Page 1 of 2 REV:13.1 Page 2 of 2 REV:13.1 AD50 Series AC/DC CONVERTER 50W Efficiency up to 80% 2500VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB Mounting mesign Metal case Model Selection Guide Order Code Efficiency(%) (Typ)Vo(V) Io(mA) Output AC(V) DC(V) Input Universal Input :85 ~ 264VAC,50/60Hz AD50 Series AC/DC CONVERTER Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1% % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms -25 +85 -40 +105 MΩ500 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Case material Metal Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area Recommend capacitive(uF) AD50-S05 10000 AD50-S09 AD50-S12 AD50-S15 AD50-S24 AD50-D05 +12 +15 AD50-D12 AD50-D15 165-264 200-370 +5000 5555 4167 3333 2083 +2083 +1667 Lateral View Mechanical Dimension & Pin Connections Bottom View 76.20 (3.00) 1.00(0.04) 76.20(3.00) 63.50(2.50) 10.16 (0.40) 20.32 (0.80) 20.32 (0.80) 40.64 (1.60) 20.00 (0.79) 4.60 (0.18) 3 4 10.16 (0.40) Note: Unit:mm(inch) NC N L +Vo 1 2 3Pin 4 Single 5 6 7 8 +S TRIM-Vo -S 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note eR ICU eR ICU www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com Note: “*” marked model is developing 1500 1200 1000 1000 1000 Page 1 of 3 REV:15.3 www.reicu.com E-mail:service @reicu.com Page 2 of 3 REV:15.3 ADN3 Series AC/DC CONVERTER 3W Efficiency up to 78% 3000VAC Isolation Single output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB mounting design Universal Input :85 ~ 264VAC,47~440Hz ADN3 Series AC/DC CONVERTER Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1 % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 120 Vp-pm Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note -25 +70 -40 +105 MΩ500 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Case material plastic eR ICU eR ICU www.reicu.com E-mail:service @reicu.com Model Selection Guide Order Code Recommend capacitive(uF) Efficiency(%) (Typ)Vo(V) Io(mA) Output AC(V) DC(V) Input ADN3-S03 ADN3-S05 500 500 3.3 ADN3-S09 ADN3-S12 ADN3-S15 85-264 120-370 333 250 200 330 330 220 220 220 Plastic case Application circuit 3 13 L N +Vo -Vo AC-DC CONVERTER + FUSE LOAD L N +Vo -Vo AC-DC CONVERTER + FUSE LOAD NTC MOV CY TVSC3 Lateral View Mechanical Dimension & Pin Connections Bottom View 22.86(0.90) 27.94(1.1) 15.24 (0.60) 20.30 (0.80) 31.80(1.25) 4.60 (0.18) 0.50(0.02) 31.80(1.25) 10.16 (0.40) 2 11 Note: Unit:mm(inch) NPL CS2 1 2 3Pin 11 Function NPCS1 13 14 24 +Vo -Vo N Page 3 of 3 REV:15.3 ADN3 Series AC/DC CONVERTEReR ICU www.reicu.com E-mail:service @reicu.com 3 13 N +Vo -Vo AC-DC CONVERTER + FUSE LOADBridge rectifiers CY C1:22uF 33uF/400V~ C2:Reference recommend capacitive C2:Reference recommend capacitive CY:2.2uF C1:4.7uF 6.8uF/400V~ C2:Reference recommend capacitive CY:2.2uF TVS:P6KE18A C3:104/50V C1:22uF 33uF/400V~ (3) (1) (2) L L:3.3-4.7uH(3.3V,5V,9V) 6.8-10uH(12V,15V) Page 1 of 2 REV:15.1 www.reicu.com E-mail:service @reicu.com Page 2 of 2 REV:15.1 ADM3_B Series AC/DC CONVERTER 3W Efficiency up to 76% 2500VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB mounting design Universal Input :85 ~ 264VAC,47~440Hz ADM3_B Series AC/DC CONVERTER Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1 % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 150 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note -25 +70 -40 +105 MΩ500 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Case material Plastic eR ICU eR ICU www.reicu.com E-mail:service @reicu.com Lateral View Mechanical Dimension & Pin Connections Bottom View Model Selection Guide Order Code Recommend capacitive(uF) Efficiency(%) (Typ)Vo(V) Io(mA) Output AC(V) DC(V) Input ADM3-S03B ADM3-S05B 600 909 3.3 ADM3-S09B ADM3-S12B ADM3-S15B ADM3-S24B ADM3-D05B +12 +15 ADM3-D12B ADM3-D15B 85-264 120-370 +300 333 250 200 125 +125 +100 330 330 220 220 220 100 Plastic case Dual Note: Unit:mm(inch) NL +Vo 1 2 3Pin 4 Single NP-Vo NL +VoCOM-Vo 5.00(0.20) 18.00 (0.71) 0.80(0.03) 38.00 (1.496) 8.12 (0.32) 18.00 (0.71) 10.6 (0.42) 31.25 (1.23) 2 3 3 % +Vo -Vo With "*" products are being developed Page 1 of 2 REV:15.2 www.reicu.com E-mail:service @reicu.com Page 2 of 2 REV:15.2 ADM3 Series AC/DC CONVERTER 3W Efficiency up to 76% 3000VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB mounting design Universal Input :85 ~ 264VAC,47~440Hz ADM3 Series AC/DC CONVERTER Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1 % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 150 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms -25 +70 -40 +105 ℃Operating Temperature Case Storage Cooling Free air convection Storage humidity %+95 General Characteristics Min Typ Max UnitsParameter Condition MΩ500 2×105 Isolation resistance MTBF K hours 500VDC Case material Plasticl(”/M” for Metal) eR ICU eR ICU www.reicu.com E-mail:service @reicu.com Model Selection Guide Order Code Recommend capacitive(uF) Efficiency(%) (Typ)Vo(V) Io(mA) Output AC(V) DC(V) Input ADM3-S03(M) ADM3-S05(M) 600 909 3.3 ADM3-S09(M) ADM3-S12(M) ADM3-S15(M) ADM3-S24(M) ADM3-D05(M) +12 +15 ADM3-D12(M) ADM3-D15(M) 85-264 120-370 +300 333 250 200 125 +125 +100 330 330 220 220 220 100 Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note Lateral View Mechanical Dimension & Pin Connections Bottom View Dual Note: Unit:mm(inch) NL +Vo 1 2 3Pin 4 Single NP-Vo NL +VoCOM-Vo 5.00(0.20) 18.00 (0.71) 0.80(0.03) 38.00 (1.496) 10.16 (0.40) 18.00 (0.71) 12.70 (0.50) 33.00 (1.30) 2 3 3 % +Vo -Vo L N +Vo -Vo FG L N FG LCM Cy Cy Cx LOAD MOV MOV MOV FUSE NTC C1 C2 TVS R EMC recommended circuit 1. FUSE:I=3*Vo*Io/ / Vin Recommend 2A/250V(10-30W) 2.NTC: 10D-09 3.MOV: 7D471K 4.LCM: 5-20mH/0.5A 5.Cx: 104/275VAC 6.Cy: 102/400VAC 7.C1: 104/50V 8.C2: Reference value for capacitor 9.TVS: P6KE20CA,SMBJ20CA AD15 Series AC/DC CONVERTEReR ICU Page 3 of 3 REV:15.1 www.reicu.com E-mail:service @reicu.com 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 -40 Metal case Plastic case Input Voltage Derating Graph Curve Output Power(%) Input Voltage(VAC) 100 85 120 264 120 Ambient temperature 25℃ 285 Safe Operating Area Application circuit AC(L) AC(N) +Vo DC/DC Converter Cout Load Fuse AC(L) AC(N) +Vo1 -Vo1 DC/DC Converter Cout Load1Fuse +Vo2 -Vo2 Cout Load2 Case material Platic Safety level Single output Others Class II Class I L N +Vo -Vo FG L N FG LCM Cy Cy Cx LOAD MOV MOV MOV FUSE NTC C1 C2 TVS R EMC recommended circuit 1. FUSE:I=3*Vo*Io/ / Vin Recommend 2A/250V(10-30W) 2.NTC: 10D-09 3.MOV: 7D471K 4.LCM: 5-20mH/0.5A 5.Cx: 104/275VAC 6.Cy: 102/400VAC 7.C1: 104/50V 8.C2: Reference value for capacitor 9.TVS: P6KE20CA,SMBJ20CA AD20 Series AC/DC CONVERTEReR ICU Page 3 of 3 REV:15.1 www.reicu.com E-mail:service @reicu.com Lateral View Mechanical Dimension & Pin Connections Bottom View DualNote: Unit:mm(inch) NC N L +Vo 1 2 3Pin 4 Single 5 6 7 8 NP NP NP -Vo Dual Island NC N L NC N L +Vo NP COM -VoNP +Vo2 -Vo2 NP +Vo1 -Vo1 48.0 (1.89) 40.0 (1.57) 70.0(2.76) 11.5 (0.45) 62.0(2.44) 23.0 (0.91) 23.5(0.93) 6.10(0.24) 1.00 (0.04) Case material Platic Safety level Single output Others Class II Class I 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 -40 Metal case Plastic case Input Voltage Derating Graph Curve Output Power(%) Input Voltage(VAC) 100 85 120 264 120 Ambient temperature 25℃ 285 Safe Operating Area Application circuit AC(L) AC(N) +Vo DC/DC Converter Cout Load Fuse AC(L) AC(N) +Vo1 -Vo1 DC/DC Converter Cout Load1Fuse +Vo2 -Vo2 Cout Load2 L N +Vo -Vo FG L N FG LCM Cy Cy Cx LOAD MOV MOV MOV FUSE NTC C1 C2 TVS R EMC recommended circuit 1. FUSE:I=3*Vo*Io/ / Vin Recommend 2A/250V(10-30W) 2.NTC: 10D-09 3.MOV: 7D471K 4.LCM: 5-20mH/0.5A 5.Cx: 104/275VAC 6.Cy: 102/400VAC 7.C1: 104/50V 8.C2: Reference value for capacitor 9.TVS: P6KE20CA,SMBJ20CA AD25 Series AC/DC CONVERTEReR ICU Page 3 of 3 REV:15.1 www.reicu.com E-mail:service @reicu.com Lateral View Mechanical Dimension & Pin Connections Bottom View DualNote: Unit:mm(inch) NC N L +Vo 1 2 3Pin 4 Single 5 6 7 8 NP NP NP -Vo Dual Island NC N L NC N L +Vo NP COM -VoNP +Vo2 -Vo2 NP +Vo1 -Vo1 48.0 (1.89) 40.0 (1.57) 70.0(2.76) 11.5 (0.45) 62.0(2.44) 23.0 (0.91) 23.5(0.93) 6.10(0.24) 1.00 (0.04) 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 -40 Metal case Plastic case Input Voltage Derating Graph Curve Output Power(%) Input Voltage(VAC) 100 85 120 264 120 Ambient temperature 25℃ 285 Safe Operating Area Application circuit AC(L) AC(N) +Vo DC/DC Converter Cout Load Fuse AC(L) AC(N) +Vo1 -Vo1 DC/DC Converter Cout Load1Fuse +Vo2 -Vo2 Cout Load2 Case material Platic Safety level Single output Others Class II Class I L N +Vo -Vo FG L N FG LCM Cy Cy Cx LOAD MOV MOV MOV FUSE NTC C1 C2 TVS R EMC recommended circuit 1. FUSE:I=3*Vo*Io/ / Vin Recommend 2A/250V(10-30W) 2.NTC: 10D-09 3.MOV: 7D471K 4.LCM: 5-20mH/0.5A 5.Cx: 104/275VAC 6.Cy: 102/400VAC 7.C1: 104/50V 8.C2: Reference value for capacitor 9.TVS: P6KE20CA,SMBJ20CA AD30 Series AC/DC CONVERTEReR ICU Page 3 of 3 REV:15.1 www.reicu.com E-mail:service @reicu.com Lateral View Mechanical Dimension & Pin Connections Bottom View DualNote: Unit:mm(inch) NC N L +Vo 1 2 3Pin 4 Single 5 6 7 8 NP NP NP -Vo Dual Island NC N L NC N L +Vo NP COM -VoNP +Vo2 -Vo2 NP +Vo1 -Vo1 48.0 (1.89) 40.0 (1.57) 70.0(2.76) 11.5 (0.45) 62.0(2.44) 23.0 (0.91) 23.5(0.93) 6.10(0.24) 1.00 (0.04) Case material Platic Safety level Single output Others Class II Class I 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 -40 Metal case Plastic case Input Voltage Derating Graph Curve Output Power(%) Input Voltage(VAC) 100 85 120 264 120 Ambient temperature 25℃ 285 Safe Operating Area Application circuit AC(L) AC(N) +Vo DC/DC Converter Cout Load Fuse AC(L) AC(N) +Vo1 -Vo1 DC/DC Converter Cout Load1Fuse +Vo2 -Vo2 Cout Load2 Plastic case (”/M” for Metal)

3000 VACInput-Output

1mA≤1minuteIsolation voltage Plastic Metal VAC2500 (Single output) )Double output) (Single output) )Double output) (Single output) )Double output) (Single output) )Double output) INPUT:85-264VAC .FG OUTPUT:5V/2000mA AC-DC CONVERTER 1515 ADM10-S05 GND. +Vo. INPUT:85-264VAC .FG OUTPUT:12V/1250mA AC-DC CONVERTER 1516 AD15-S12 GND. +Vo. INPUT:85-264VAC OUTPUT:12V/2500mA AC-DC CONVERTER 1520 AD30-S12 .FG GND. +Vo. INPUT:85-264VAC .FG OUTPUT:5V/1000mA AC-DC CONVERTER 1512 ADM5-S05 GND. +Vo. Page 1 of 3 REV:15.1 Page 2 of 3 REV:15.1 ADM10 Series AC/DC CONVERTER 10W Efficiency up to 80% 3000VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB Mounting mesign Plastic case Model Selection Guide Order Code Efficiency(%) (Typ)Vo(V) Io(mA) Output ADM10-S03 ADM10-S05 AC(V) DC(V) Input 2000 2000 3.3 Universal Input :85 ~ 264VAC,50/60Hz ADM10-S09 ADM10-S12 ADM10-S15 ADM10-S24 ADM10-D05 +12 +15 ADM10-D12 ADM10-D15 85-264 120-370 +1000 1111 833 667 417 +417 +333 Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1% % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms ADM10-D05-05 ADM10-D05-24 5/12 1600/200ADM10-D05-12 5/24 1000/200 -25 +85 -40 +105 MΩ500 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Case material Platic Recommend capacitive(uF) Lateral View Mechanical Dimension & Pin Connections Bottom View DualNote: Unit:mm(inch) NC N L +Vo 1 2 3Pin 4 Single 5 6 7 8 NP NP NP -Vo Dual Island NC N L NC N L +Vo NP COM -VoNP +Vo2 -Vo2 NP +Vo1 -Vo1 45.0 (1.77) 35.00 (1.38) 55.0(2.17) 10.0 (0.390) 47.0(1.85) 20.0 (0.79) 20.5(0.81) 6.10(0.24) 1.00 (0.04) 1000 1000 470 470 470 330 eR ICU ADM10 Series AC/DC CONVERTEReR ICU www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com L N +Vo -Vo FG L N FG LCM Cy Cy Cx LOAD MOV MOV MOV FUSE NTC C1 C2 TVS R EMC recommended circuit 1. FUSE:I=3*Vo*Io/ / Vin Recommend 2A/250V(10-30W) 2.NTC: 10D-09 3.MOV: 7D471K 4.LCM: 5-20mH/0.5A 5.Cx: 104/275VAC 6.Cy: 102/400VAC 7.C1: 104/50V 8.C2: Reference value for capacitor 9.TVS: P6KE20CA,SMBJ20CA ADM10 Series AC/DC CONVERTEReR ICU Temperature Derating Graph Curve 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 -40 Metal case Plastic case Input Voltage Derating Graph Curve Output Power(%) Input Voltage(VAC) 100 85 120 264 120 Ambient temperature 25℃ 285 Safe Operating Area Application circuit AC(L) AC(N) +Vo DC/DC Converter Cout Load Fuse AC(L) AC(N) +Vo1 -Vo1 DC/DC Converter Cout Load1Fuse +Vo2 -Vo2 Cout Load2 Page 3 of 3 REV:15.1 www.reicu.com E-mail:service @reicu.com Safety level Single output Others Class II Class I (Single output) )Double output) Page 1 of 2 REV:15.2 www.reicu.com E-mail:service @reicu.com Page 2 of 2 REV:15.2 ADN5 Series AC/DC CONVERTER 5W Efficiency up to 79% 3000VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB mounting design Universal Input :85 ~ 264VAC,47~440Hz ADN5 Series AC/DC CONVERTER Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1% % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms -25 +70 -40 +105 ℃Operating Temperature Case Storage Cooling Free air convection Storage humidity %+95 General Characteristics Min Typ Max UnitsParameter Condition eR ICU eR ICU www.reicu.com E-mail:service @reicu.com Model Selection Guide Order Code Recommend capacitive(uF) Efficiency(%) (Typ)Vo(V) Io(mA) Output AC(V) DC(V) Input ADN5-S03 ADN5-S05 1000 1000 3.3 ADN5-S09 ADN5-S12 ADN5-S15 ADN5-S24 ADN5-D05 +12 +15 ADN5-D12 ADN5-D15 85-264 120-370 +500 556 417 333 208 +208 +167 330 330 220 220 220 100 Plastic case (”/M” for Metal) Note:"*"maked model is developing Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note Lateral View Mechanical Dimension & Pin Connections Bottom View Dual Note: Unit:mm(inch) +Vo 1 2 3Pin 4 Single NP GNDN L +Vo COM -Vo 22.0(0.866) 5.30(0.21) 25.0 (0.984) 10.60 (0.417) 39.0(1.535) 4.0 (0.157) 31.3(1.232) 8.0 (0.314) 2 3 1.00(0.04)Φ MΩ500 2×105 Isolation resistance MTBF K hours 500VDC Case material Plasticl(”/M” for Metal) 1mA≤1minuteIsolation voltage Plastic Metal VAC2500 N L Page 1 of 2 REV:16.1 www.reicu.com E-mail:service @reicu.com Page 2 of 2 REV:16.1 ADM3-D_D1 Series AC/DC CONVERTER 3W Efficiency up to 67% 3000VAC Isolation Double iso output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB mounting design Universal Input :85 ~ 264VAC,47~440Hz ADM3-D_D1 Series AC/DC CONVERTER -25 +70 -40 +105 ℃Operating Temperature Case Storage Cooling Free air convection Storage humidity %+95 General Characteristics Min Typ Max UnitsParameter Condition MΩ500 2×105 Isolation resistance MTBF K hours 500VDC Case material Plasticl eR ICU eR ICU www.reicu.com E-mail:service @reicu.com Model Selection Guide Order Code Recommend capacitive(uF) Efficiency(%) (Typ)Vo1/Vo2(V) Io1/Io2(mA) Output AC(V) DC(V) Input ADM3-D05-05D1 ADM3-D05-09D1 400/100 ADM3-D05-12D1 ADM3-D05-24D1 85-264 120-370 350/100 Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note Lateral View Mechanical Dimension & Pin Connections Bottom View Note: Unit:mm(inch) NL +Vo2 1 2 3Pin 4 Function -Vo2 Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1 % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 55 Vp-pm 120 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms 2 % Vo1 Vo2 Plastic case

3000 VACInput-Output 2mA≤1minuteIsolation voltage

37.00(1.460) 18.00 (0.71) 15.24 (0.60) 19.00(0.75) 1 2 3 5.08 (0.20) 6.35 (0.25) 2.54 (0.10) 3.18 (0.13) 5.00(0.20) 17.00 (0.67) 1.00(0.04) -Vo1+Vo1 FG 6 7 Page 1 of 2 REV:16.1 www.reicu.com E-mail:service @reicu.com Page 2 of 2 REV:16.2 ADN6 Series AC/DC CONVERTER 6W Efficiency up to 79% 3000VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB mounting design Universal Input :85 ~ 264VAC,47~440Hz ADN6 Series AC/DC CONVERTER Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1% %

65 KHzSwitching frequency Full load,nominal input

Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms -25 +70 -40 +105 ℃Operating Temperature Case Storage Cooling Free air convection Storage humidity %+95 General Characteristics Min Typ Max UnitsParameter Condition eR ICU eR ICU www.reicu.com E-mail:service @reicu.com Model Selection Guide Order Code Recommend capacitive(uF) Efficiency(%) (Typ)Vo(V) Io(mA) Output AC(V) DC(V) Input ADN6-S03 ADN6-S05 1200 1200 3.3 ADN6-S09 ADN6-S12 ADN6-S15 ADN6-S24 ADN6-D05 +12 +15 ADN6-D12 ADN6-D15 85-264 120-370 +600 667 500 400 250 +250 +200 330 330 220 220 220 100 Plastic case (”/M” for Metal) Note:"*"maked model is developing Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note Lateral View Mechanical Dimension & Pin Connections Bottom View Dual Note: Unit:mm(inch) +Vo 1 2 3Pin 4 Single NP GNDN L +Vo COM -Vo 22.0(0.866) 5.30(0.21) 25.0 (0.984) 10.60 (0.417) 39.0(1.535) 4.0 (0.157) 31.3(1.232) 8.0 (0.314) 2 3 1.00(0.04)Φ MΩ500 2×105 Isolation resistance MTBF K hours 500VDC Case material Plasticl(”/M” for Metal) 1mA≤1minuteIsolation voltage Plastic Metal VAC2500 N L Page 1 of 2 REV:15.1 www.reicu.com E-mail:service @reicu.com Page 2 of 2 REV:15.1 ADMN3_ Series AC/DC CONVERTER 3W Efficiency up to 72% 3000VAC Isolation Single output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB mounting design Universal Input :85 ~ 264VAC,47~440Hz ADMN3_ Series AC/DC CONVERTER Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note -25 +70 -40 +105 MΩ100 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Case material Plastic eR ICU eR ICU www.reicu.com E-mail:service @reicu.com Plastic case Lateral View Mechanical Dimension & Pin Connections Bottom View Note: Unit:mm(inch) N L +Vo 1 2 3Pin 4 Single -Vo 5.00(0.20) 15.00 (0.59) 0.80(0.03) 32.00 (1.26) 20.00 (0.79) 15.24 (0.60) 27.94 (1.10) 2 3 Model Selection Guide Order Code Recommend capacitive(uF) Efficiency(%) (Typ)Vo(V) Io(mA) Output AC(V) DC(V) Input ADMN3-S05 ADMN3-S09 333 600 ADMN3-S12 ADMN3-S15 ADMN3-S24 85-264 120-370 250 200 125 220 100 100 100 220 Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy +5 %+Vo Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 80 Vp-pm 120 Short circuit Protection Continuous,Automatic Recovery Transient Recovery Time 200 ms25% Load Step Change Hold-up time ms EMC Conduction and radiation EN55011,EN55022 CLASS B(EMC Recommended circuit) L N +Vo -Vo L N LCM Cy Cy Cx LOAD MOV MOV MOV FUSE NTC C1 C2 TVS 1. FUSE:I=3*Vo*Io/ / Vin Recommend 0.5A/250V 2.NTC: 10D-09 3.MOV: 7D471K 4.LCM: 5-20mH/0.5A 5.Cx: 104/275VAC 6.Cy: 102/400VAC 7.C1: 104/50V 8.C2: Reference value for capacitor 9.TVS: P6KE20CA,SMBJ20CA Recommended circuit L N +Vo -Vo L N LOAD FUSE NTC C1 C2 (Tye) (EMC) Page 1 of 2 REV:15.1 www.reicu.com E-mail:service @reicu.com Page 2 of 2 REV:15.1 ADMN5_ Series AC/DC CONVERTER 5W Efficiency up to 78% 3000VAC Isolation Single output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB mounting design Universal Input :85 ~ 264VAC,47~440Hz ADMN5_ Series AC/DC CONVERTER Input Characteristics Min Typ Max UnitsParameter Condition AC DC 165 200 264 380 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note -25 +60 -40 +105 MΩ100 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Case material Plastic eR ICU eR ICU www.reicu.com E-mail:service @reicu.com Plastic case Model Selection Guide Order Code Recommend capacitive(uF) Efficiency(%) (Typ)Vo(V) Io(mA) Output AC(V) DC(V) Input ADMN5-S05 ADMN5-S09 500 800 ADMN5-S12 ADMN5-S15 ADMN5-S24 165-264 200-380 417 333 208 470 220 220 100 470 Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy +3 %+Vo Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 80 Vp-pm 120 Short circuit Protection Continuous,Automatic Recovery Transient Recovery Time 100 ms25% Load Step Change Hold-up time ms EMC Conduction and radiation EN55011,EN55022 CLASS B(EMC Recommended circuit) L N +Vo -Vo L N LCM Cy Cy Cx LOAD MOV MOV MOV FUSE NTC C1 C2 TVS 1. FUSE:I=3*Vo*Io/ / Vin Recommend 0.5A/250V 2.NTC: 10D-09 3.MOV: 10D471K 4.LCM: 5-20mH/0.5A 5.Cx: 104/275VAC 6.Cy: 102/400VAC 7.C1: 104/50V 8.C2: Reference value for capacitor 9.TVS: P6KE20CA,SMBJ20CA Recommended circuit L N +Vo -Vo L N LOAD FUSE NTC C1 C2 (Tye) (EMC) Lateral View Mechanical Dimension & Pin Connections Bottom View Note: Unit:mm(inch) N L +Vo 1 2 3Pin 4 Single -Vo 5.00(0.20) 15.00 (0.59) 0.80(0.03) 32.00 (1.26) 20.00 (0.79) 15.24 (0.60) 27.94 (1.10) 2 3 Page 1 of 2 REV:15.1 www.reicu.com E-mail:service @reicu.com Page 2 of 2 REV:15.1 AS3_ Series AC/DC CONVERTER 3W Efficiency up to 72% 3000VAC Isolation Single output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB mounting design Universal Input :85 ~ 264VAC,47~440Hz AS3_ Series AC/DC CONVERTER Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note eR ICU eR ICU www.reicu.com E-mail:service @reicu.com SIP Mechanical Dimension & Pin Connections Note: Unit:mm(inch) N L +Vo 1 2 3Pin 4 Single -Vo Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy +5 %+Vo Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 80 Vp-pm 150 Short circuit Protection Continuous,Automatic Recovery Transient Recovery Time 200 ms25% Load Step Change Hold-up time ms -25 +70 -40 +105 MΩ100 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Case material Plastic EMC Conduction and radiation EN55011,EN55022 CLASS B(EMC Recommended circuit) Recommended circuit (Tye) (EMC) 5 6 C+ C- Model Selection Guide Order Code Recommend capacitive(uF) Efficiency(%) (Typ)Vo(V) Io(mA) Output AC(V) DC(V) Input AS3-S05 AS3-S09 333 600 AS3-S12 AS3-S15 AS3-S24 85-264 120-370 250 200 125 220 100 100 100 220 AS3-S03 3.3 600 330 65 L N +Vo -Vo L N LCM Cy Cy Cx LOAD MOV MOV MOV FUSE C1 C2 TVS CY C-C3 L N +Vo -Vo L N LOADMOV FUSE C1 C2 TVS CY C-C3 NTC 1. FUSE:I=3*Vo*Io/ / Vin Recommend 0.5A/250V 2.NTC:13D-5 3.MOV: 14D561K 4.LCM: 5-20mH/0.5A 5.Cx: 104/275VAC 6.Cy: 102/400VAC 7.C3: 4.7uF/450V 8.2.2uF/400VAC 9.C1: 104/50V 10.C2: Reference value for capacitor 11.TVS: P6KE20CA,SMBJ20CA Lateral ViewBottom View 33.00 (1.30) 17.50 (0.69) 7.00 (0.28) 3.06 (0.12) 5.08 (0.20) 5.08 (0.20) 7.62 (0.30) 7.00 (0.28) 12.00 (0.47) 1 2 3 4 5 6 0.85 (0.03) Full load Page 1 of 2 REV:15.2 www.reicu.com E-mail:service @reicu.com Page 2 of 2 REV:15.2 ADN5_E Series AC/DC CONVERTER 5W Efficiency up to 78% 3000VAC Isolation Single output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB mounting design Universal Input :85 ~ 264VAC,47~440Hz ADN5_E Series AC/DC CONVERTER Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 380 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 Safe Operating Area 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note -25 +60 -40 +105 MΩ100 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Case material Plastic eR ICU eR ICU www.reicu.com E-mail:service @reicu.com Plastic case Model Selection Guide Order Code Recommend capacitive(uF) Efficiency(%) (Typ)Vo(V) Io(mA) Output AC(V) DC(V) Input ADN5-S05E ADN5-S09E 500 800 ADN5-S12E ADN5-S15E ADN5-S24E 85-264 120-380 417 333 208 470 220 220 100 470 Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy +3 %+Vo Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 80 Vp-pm 120 Short circuit Protection Continuous,Automatic Recovery Transient Recovery Time 100 ms25% Load Step Change Hold-up time ms EMC Conduction and radiation EN55011,EN55022 CLASS B(EMC Recommended circuit) L N +Vo -Vo L N LCM Cy Cy Cx LOAD MOV MOV MOV FUSE NTC C1 C2 TVS 1. FUSE:I=3*Vo*Io/ / Vin Recommend 0.5A/250V 2.NTC: 10D-09 3.MOV: 10D471K 4.LCM: 5-20mH/0.5A 5.Cx: 104/275VAC 6.Cy: 102/400VAC 7.C1: 104/50V 8.C2: Reference value for capacitor 9.TVS: P6KE6.8A--5V P6KE12A--9V P6KE16A--12V P6KE20A--15V P6KE33A--24V Recommended circuit L N +Vo -Vo L N LOAD FUSE NTC C1 C2 (Tye) (EMC) Mechanical Dimension & Pin Connections Full load Lateral ViewBottom View Note: Unit:mm(inch) +Vo 1 2 3Pin 4 Function GNDLN 16.0(0.63) 5.30(0.21) 25.0 (0.984) 10.60 (0.417) 37.5(1.476) 31.3(1.232) 8.0 (0.314) 2 3 0.80(0.03)Φ Page 1 of 3 REV:15.1 Page 2 of 3 REV:15.1 AD40 Series AC/DC CONVERTER 40W Efficiency up to 84% 3000VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB Mounting mesign Plastic case Universal Input :85 ~ 264VAC,50/60Hz AD40 SERIES AC/DC CONVERTER Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1% % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms -25 +85 -40 +105 MΩ500 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC eR ICU eR ICU www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com L N +Vo -Vo FG L N FG LCM Cy Cy Cx LOAD MOV MOV MOV FUSE NTC C1 C2 TVS R EMC recommended circuit 1. FUSE:I=3*Vo*Io/ / Vin Recommend 3A/250V 2.NTC: 10D-09 3.MOV: 14D471K 4.LCM: 5-20mH/0.5A 5.Cx: 104/275VAC 6.Cy: 102/400VAC 7.C1: 104/50V 8.C2: Reference value for capacitor 9.TVS: P6KE16CA P6KE33CA AD40 SERIES AC/DC CONVERTEReR ICU Page 3 of 3 REV:15.1 www.reicu.com E-mail:service @reicu.com Lateral View Mechanical Dimension & Pin Connections Bottom View Note: Unit:mm(inch) NC N L +Vo 1 2 3Pin 4 Single 5 6 7 8 NP NP NP -Vo 48.0 (1.89) 40.0 (1.57) 70.0(2.76) 11.5 (0.45) 62.0(2.44) 23.0 (0.91) 23.5(0.93) 6.10(0.24) 1.00 (0.04) Case material Platic Safety level Single output Class II 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 -40 Plastic case Input Voltage Derating Graph Curve Output Power(%) Input Voltage(VAC) 100 85 120 264 120 Ambient temperature 25℃ 285 Safe Operating Area Application circuit AC(L) AC(N) +Vo DC/DC Converter Cout Load Fuse Model Selection Guide Order Code Efficiency(%) (Typ)Vo(V) Io(mA) Output AC(V) DC(V) Input Recommend capacitive(uF) AD40-S05 70005 2200 77.5 AD40-S12 AD40-S15 AD40-S24 3333 2666 1666 680 680 470 AD40-S48 48 165-264 200-370 833 470 87 EMC IEC/EN 61000-4-4 4kV IEC/EN 61000-4-5 2kV Burst of pulses(脉冲群) Surging (浪涌) Conducted disturbance(传导与辐射) EN55022 CLASS B Electrostatic discharge(静电放电) IEC/EN 61000-4-2 8kV RF Electromagnetic Field Immunity(射频辐射抗扰) IEC/EN 61000-4-3 Reference application circuit Page 1 of 3 REV:15.2 Page 2 of 3 REV:15.2 ADM50 SERIES AC/DC CONVERTER 50W Efficiency up to 84% 3000VAC Isolation Single/Double output Wide temperature -25℃ to 70℃ short circuit protection Power modules for PCB Mounting mesign Plastic case Universal Input :85 ~ 264VAC,50/60Hz ADM50 SERIES AC/DC CONVERTER Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 375 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 1% % Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Short circuit Protection Continuous,Automatic Recovery +0.5 +1 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Hold-up time 50 ms -25 +70 -40 +85 MΩ500 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 1mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC eR ICU eR ICU www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com L N +Vo -Vo FG L N FG LCM Cy Cy Cx LOAD MOV MOV MOV FUSE NTC C1 C2 TVS R EMC recommended circuit 1. FUSE:I=3*Vo*Io/ / Vin Recommend 3A/250V 2.NTC: 10D-09 3.MOV: 14D471K 4.LCM: 5-20mH/0.5A 5.Cx: 104/275VAC 6.Cy: 102/400VAC 7.C1: 104/50V 8.C2: Reference value for capacitor 9.TVS: P6KE16CA P6KE33CA ADM50 SERIES AC/DC CONVERTEReR ICU Page 3 of 3 REV:15.2 www.reicu.com E-mail:service @reicu.com Lateral View Mechanical Dimension & Pin Connections Bottom View Note: Unit:mm(inch) NC N L +Vo 1 2 3Pin 4 Single 5 6 7 8 NP NP NP -Vo 48.0 (1.89) 40.0 (1.57) 70.0(2.76) 11.5 (0.45) 62.0(2.44) 23.0 (0.91) 23.5(0.93) 6.10(0.24) 1.00 (0.04) Case material Platic Safety level Single output Class II 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note Temperature Derating Graph Curve Output Power(%) Operating Temperature(℃) 100 -25 0 25 7550 120 100 -40 Input Voltage Derating Graph Curve Output Power(%) Input Voltage(VAC) 100 85 120 264 120 Ambient temperature 25℃ 285 Safe Operating Area Application circuit AC(L) AC(N) +Vo DC/DC Converter Cout Load Fuse Model Selection Guide Order Code Efficiency(%) (Typ)Vo(V) Io(mA) Output AC(V) DC(V) Input Recommend capacitive(uF) ADM50-S12 ADM50-S15 ADM50-S24 4000 3300 2000 680 680 470 ADM50-S48 48 85-264 120-370 1000 470 88 EMC IEC/EN 61000-4-4 4kV IEC/EN 61000-4-5 2kV Burst of pulses(脉冲群) Surging (浪涌) Conducted disturbance(传导与辐射) EN55022 CLASS B Electrostatic discharge(静电放电) IEC/EN 61000-4-2 8kV RF Electromagnetic Field Immunity(射频辐射抗扰) IEC/EN 61000-4-3 Reference application circuit 100 Page 1 of 2 REV:16.1 Page 2 of 2 REV:16.1 ADL20 Series AC/DC CONVERTER 20W Efficiency up to 86% 4000VAC Isolation Single output Wide temperature -25℃ to 70℃ Over load/short circuit protection Power modules for PCB Mounting mesign Plastc case Model Selection Guide Order Code Efficiency(%) (Typ)Vo(V) Io(mA) Output AC(V) DC(V) Input Universal Input :85 ~ 264VAC,50/60Hz ADL20 Series AC/DC CONVERTER ADL20-S03 ADL20-S05 ADL20-S12 ADL20-S15 ADL20-S24 85-264 120-370 1667 1333 833 Input Characteristics Min Typ Max UnitsParameter Condition AC DC 120 264 370 Hz Input Voltage Range Input Frequency AC 47 440 VAC VDC Output Characteristics Min Typ Max UnitsParameter Condition Output Voltage Accuracy 2% %

100 KHzSwitching frequency Full load,nominal input

Line regulation Vin(Min~Max) % Load regulation Ripple and noise 10%~100% load 20MHz 50 Vp-pm 100 Transient Recovery Time 500 us25% Load Step Change +1+0.5 Short circuit Protection Continuous,Automatic Recovery EMC Derating Graph Curve Recommend capacitive(uF) Lateral View Mechanical Dimension & Pin Connections Bottom View 1.All the specifications typical at Ta=+25℃ resistive load, nominal input voltage and rated output current unless otherwise noted. 2.Operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. 3.Ripple & Noise measurement bandwidth is 0-20MHz. 3.Other input and output voltage may be available, please 4.All AC/DC converters should be externally fused at the front end for protection. 5 Specifications subject to change without notice. Note 220 220 100 eR ICU eR ICU www.reicu.com E-mail:service @reicu.com www.reicu.com E-mail:service @reicu.com 25.4 (1.00) 10.16 (0.40) 53.90(2.12) 45.72(1.80) 20.32 (0.80) 23.70(0.93) 0.80(0.032) Note: Unit:mm(inch) N L +Vo 1 2 3Pin 4 Function -Vo 5 3500 83 3.3 3500 470 82 470 -25 +70 -25 +85

4000 VAC

MΩ100 2×105 Operating Temperature Case Storage Cooling Free air convection Input-Output 5mA≤1minuteIsolation voltage Isolation resistance MTBF Storage humidity %+95 K hours General Characteristics Min Typ Max UnitsParameter Condition 500VDC Case material Platic IEC/EN 61000-4-4 4kV IEC/EN 61000-4-5 2kV Burst of pulses(脉冲群) Surging (浪涌) Conducted disturbance(传导与辐射) En55022 CLASS B Electrostatic discharge(静电放电) IEC/EN 61000-4-2 8kV RF Electromagnetic Field Immunity(射频辐射抗扰) IEC/EN 61000-4-3 Reference application circuit 100 -40 0 50 85 OUTPUT:3.3V/5V/9V Others Output Power(%) Ambient Temperature(℃) Temperature derating curve 100 85 100 240 264 OUTPUT:5.0V Others Output Power(%) Input Voltage Input voltage derating curve 130 100 120 160 340 370 VAC VDC 55-25 70