Parameter Conditions Min. Typ. Max. Units Input Voltage Range Universal 100 240 VAC 127 370 VDC Input Frequency 47 63 Hz Inrush Current, Cold Start 110 VAC 22 A
220 VAC 44 A
Leakage Current 264 VAC 1.8 mA Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy ±0.5 % Output Voltage Adjustment Range Primary Output Only ±10.0 % Line Regulation Vin = Min to Max ±1.0 % Load Regulation (Note 1) Iout = 20% to 100% ±1.0 % Hold Time 110 VAC, Full Load 10 mSec220 VAC, Full Load 20 Ripple & Noise (20 MHz) (Note 2) See Model Selection Guide Output Power Protection Power Limit 130 160 % Transient Recovery Time (Note 3) 50% Load Change 2m S Transient Response Deviation 5 % Temperature Coeffi cient ±0.04 ±0.05 %/ºC Output Short Circuit Continuous With Autorecovery General Parameter Conditions Min. Typ. Max. Units Isolation Voltage Input - Output 3,000 VACInput - FG (Frame Ground) 2,000 Output - FG (Frame Ground) 500 Isolation Resistance (Note 4) 500 VDC 100 MΩ Switching Frequency Fixed 130 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -20 +25 +50 ºC Storage Temperature Range -20 +85 ºC Cooling Free Air Convection Humidity RH, Non-condensing 95 % Vibration 10 Hz ~ 2 kHz; 2G 10 min./1 Cycle; X, Y, Z axis each 1 hour Physical Case Material Aluminum (Base) and Steel (Cover) Connection Screw Terminal Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F, 25ºC, Gnd Benign 100 kHours Safety Standards UL 1950, EN 60950, IEC 60950 EMI Compliance Compliance to EN55011, EN55022 (CISPR22) Class B EMS Immunity Compliance EN6100-4-2,3,4,5,6,8,11 Level 3 Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. New Industrial Supplies!!Key Features:
- 360W Output Power
- DIN Rail Mountable
- Universal AC Input
- Dual Outputs
- UL 508 Compliant
- EN60950 Compliant
- Cond./Rad. EMI Class B
- >100 kH MTBF
- LOW COST! Very Low Cost, 360W DIN Rail Mount Dual Output AC/DC Power Supplies RoHS Compliant MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Models available from 20W! Call today for details
Notes:
- All dimensions are typical in inches (mm)
- Tolerance x.xx = ±0.01 (±0.25) MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com Model Number Rated Power (W) Input Output Overvoltage Protection (VDC) Ripple & Noise (mV p-p) Effi ciency (%, Typ)Voltage (VAC) Current (A) Voltage (VDC) Current (A) Max) Current (A) Range Universal Range 115 VAC 230 VAC Notes: 1. Load regulation is specifi ed for a load change of 20% to 100%. For models AD23601C, load regulation for V1 (12V) is ±2% 2. Ripple & noise is measured using equipment with
20 Mhz of bandwidth with the unit under test
operating at rated load and a 110 VAC input. Connection to the unit is made with a 0.1 μF / 630V metalized capacitor & a 47 μF electrolytic capacitor connected in parallel. 3. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. 4. Isolation resistance is given for Input/Output and Input/FG. For Output/FG., it is 50 MΩ 5. Overload protection is power limiting. The unit recovers automatically when the fault is removed. 6. Over voltage protection is a shut down type. The unit recovers automatically when the fault is removed. 7. To mount the unit to the DIN rail, tilt the unit rearwards from the top, fi tting the mount over the top of the rail. Press back on the bottom front of the unit until it locks in place on the rail. To remove the unit from the rail, pull the removal clip at the bottom rear of the unit downward with a screw driver. With the clip down, lift up on the unit from the bottom front until it clears the rail. Before installation or removal all wiring should be disconnected and the main power to the system shut off. 8. When wiring the supply, all lines should be as thick and short as possible. AWG 14 wire is recom- mended for the AD2360C series. 9. The units should be mounted so they are vertically orientated. Air fl ow (if provided) would optimally fl ow from the bottom to the top of the unit. 10. It is recommended that a fuse be used on the input of a power supply for protection. For the AD2360C series a 250VAC 5.0A is recom- mended. Connections TB 1 Pin Function
1 FT (Optional)
2 FT (Optional)
2 (5V) Output
4 Output Common
5 Output Common
1 AC Input - Live
2 AC Input - Neutral
3 Frame Ground (FG
Units with the optional “FT” outputs may be easily connected for “Fault Tolerant operation. Contact the factory for details