Technical content

< E1-Type approval < Analog output 4 mA ... 20 mA < Fixed evaluation limits < High shock resistance < Teachable zero point < Measuring range -2 g ... +2 g < Increased noise immunity 100 V/m 2 axis acceleration sensor Dimensions 10 45 10 4 x ø 5.5 M12 7 30 7 18.5 LEDs Technical Data General specifications Type 2 axis acceleration sensor Measurement range -2 ... 2 g Resolution ≤ 5 mg Repeat accuracy ≤ ± 5 mg Frequency range 0 ... 100 Hz Functional safety related parameters MTTFd 304 a Mission Time (TM) 20 a Release date: 2020-04--

24 Date of

Release date: 2020-04-24 Date of issue: 2020-04-24 Filename: 227702_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

Diagnostic Coverage (DC) 0 % Indicators/operating means Operation indicator LED, green Teach-In indicator LED, yellow Electrical specifications Operating voltage UB 10 ... 30 V DC No-load supply current I0 ≤ 25 mA Time delay before availability tv ≤ 100 ms Analog output Output type 2 current outputs 4 ... 20 mA (one output for each axis) Zero signal 12 mA Slope of output characteristic 4 mA / g Linearity error ± 1.2 % Temperature influence Offset ≤ ± 4 µA / K Slope ≤ ± 20 µA / g Compliance with standards and directives Standard conformity Shock and impact resistance 100 g according to DIN EN 60068-2-27 Standards EN 60947-5-2:2007 IEC 60947-5-2:2007 Approvals and certificates UL approval cULus Listed, Class 2 Power Source CCC approval CCC approval / marking not required for products rated ≤36 V E1 Type approval 10R-04 Ambient conditions Mechanical specifications Connection type 5-pin, M12 x 1 connector Housing material PA Degree of protection IP68 / IP69K Mass 240 g Connection Analog output Y Analog output X 1 +U B -U B T each-In Acceleration sensor ACY04-F99-2I-V15 Release date: 2020-04-24 Date of issue: 2020-04-24 Filename: 227702_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

Wire colors in accordance with EN 60947-5-2 (brown) (white) (blue) (black) (gray) Characteristic Curve 1 10 100 1000 -10 -12 -14 Frequency response 20 x log (output signal / stimulus) [dB] frequency [Hz] Accessories V15-G-2M-PUR Female cordset, M12, 5-pin, PUR cable Acceleration sensor ACY04-F99-2I-V15 Release date: 2020-04-24 Date of issue: 2020-04-24 Filename: 227702_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

Release date: 2020-04-24 Date of issue: 2020-04-24 Filename: 227702_eng.pdf ACY04-F99-2I-V15 Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Acceleration sensor Installation orientation On delivery, the zero position of the sensor axes is achieved when the sensor is mounted flat on a horizontal plane and the electrical connection of the sensor points horizontally sidewards. LED display Factory settings see Technical Data Teach-in of reference point (output S1) 1. Move sensor to reference position 2. Apply supply voltage (+Ub) to Teac h In input (Pin 5) for 1 s ... 10 s 3. Teach In LED lights up for confirmation 4. Disconnect Teach In input (Pin 4) before the 10 s time elapses 5. Teach In LED flashes 3 x for confirmation 6. Reference point is now programmed and the sensor returns to normal operation (see LED display) Resetting the sensor to factory settings 1. Apply supply voltage (+Ub) to Teac h In input (Pin 5) for 20 s ... 25 s 2. Teach In LED lights up for confirmation 3. Disconnect Teach In input (Pin 4) before the 25 s time elapses 4. Teach In LED and Out LED flash 3 x for confirmation 5. The sensor is now reseted to factory settings and returns to normal operation (see LED display) Undervoltage detection If the supply voltage falls below a value of approx. 7 V, all outputs and yellow LEDs are deactivated. The green "power" LED flashes rapidly. If the supply voltage rises above a value of approx. 8 V, the sensor continues with normal operation. Mounting of the sensor Sensors from the -F99 series consist of a sensor module and accompanying cast aluminum housing. Select a horizontal flat surface with minimum dimensions of 70 mm x 50 mm to mount the sensor. Mount the sensor as follows: 1. Loosen the central screw un der the sensor connection. 2. Slide back the clamping element until you are able to remove the sensor module from the housing. 3. Remove the sensor mo dule from the housing 4. Position the housing at the required moun ting location and secure using four countersunk screws. Make sure that the heads of the screws do not protrude. 5. Place the sensor mo dule in the housing. Mounting Additional Information Displays dependent on the operating state LED green: Power LED yellow 1 LED yellow 2 Normal operation on off off Teach In of reference point Teach In (Pin 5 connected to +UB) for 1 s ... 10 s falling slope at Teach In input then sensor returns to normal operation. on on on on flashes 3 x off off off off Reset to factory settings: Teach In (Pin 5 connected to +UB) for 20 s ... 25 s falling slope at Teach In input then sensor returns to normal operation. on on on on flashes 3 x off off flashes 3 x off Undervoltage flashes off off Mounting 3 Nm 1.2.

Release date: 2020-04-24 Date of issue: 2020-04-24 Filename: 227702_eng.pdf ACY04-F99-2I-V15 Germany: +49 621 776 1111Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091 Acceleration sensor 6. Slide the clamping element flush in to the housing. Check that the sensor element is seated correctly. 7. Finally tighten the central screw. The sensor is now mounted correctly. EMC Properties Interference immunity in accordance with DIN ISO 11452-2: 100 V/m Frequency band 20 MHz up to 2 GHz Mains-borne interference in accordance with ISO 7637-2: Technical Features Pulse 1 2 a b a b Severity level I I I I I I I I I I I I I I I I I I Failure criterion CACAAC EN 61000- 4-2: CD: 8 kV AD: 15 kV Severity level IV IV EN 61000- 4-3: Severity level IV EN 61000- 4-4: 2 kV Severity level III EN 61000- 4-6: Severity level III EN 55011: Klasse A